Merge pull request (#102) - Phase 6.4 Stream D server-side
This commit was merged in pull request #102.
This commit is contained in:
@@ -0,0 +1,91 @@
|
||||
using ZB.MOM.WW.OtOpcUa.Configuration.Entities;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Core.OpcUa;
|
||||
|
||||
/// <summary>
|
||||
/// Phase 6.4 Stream D: materializes the OPC 40010 Machinery companion-spec Identification
|
||||
/// sub-folder under an Equipment node. Reads the nine decision-#139 columns off the
|
||||
/// <see cref="Equipment"/> row and emits one property per non-null field.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para>Pure-function shape — testable without a real OPC UA node manager. The caller
|
||||
/// passes the builder scoped to the Equipment node; this class handles the Identification
|
||||
/// sub-folder creation + per-field <see cref="IAddressSpaceBuilder.AddProperty"/> calls.</para>
|
||||
///
|
||||
/// <para>ACL binding: the sub-folder + its properties inherit the Equipment scope's
|
||||
/// grants (no new scope level). Phase 6.2's trie treats them as part of the Equipment
|
||||
/// ScopeId — a user with Equipment-level grant reads Identification; a user without the
|
||||
/// grant gets BadUserAccessDenied on both the Equipment node + its Identification variables.
|
||||
/// See <c>docs/v2/acl-design.md</c> §Identification cross-reference.</para>
|
||||
///
|
||||
/// <para>The nine fields per decision #139 are exposed exactly when they carry a non-null
|
||||
/// value. A row with all nine null produces no Identification sub-folder at all — the
|
||||
/// caller can use <see cref="HasAnyFields(Equipment)"/> to skip the Folder call entirely
|
||||
/// and avoid a pointless empty folder appearing in browse trees.</para>
|
||||
/// </remarks>
|
||||
public static class IdentificationFolderBuilder
|
||||
{
|
||||
/// <summary>Browse + display name of the sub-folder — fixed per OPC 40010 convention.</summary>
|
||||
public const string FolderName = "Identification";
|
||||
|
||||
/// <summary>
|
||||
/// Canonical decision #139 field set exposed in the Identification sub-folder. Order
|
||||
/// matches the decision-log entry so any browse-order reader can cross-reference
|
||||
/// without re-sorting.
|
||||
/// </summary>
|
||||
public static IReadOnlyList<string> FieldNames { get; } = new[]
|
||||
{
|
||||
"Manufacturer", "Model", "SerialNumber",
|
||||
"HardwareRevision", "SoftwareRevision",
|
||||
"YearOfConstruction", "AssetLocation",
|
||||
"ManufacturerUri", "DeviceManualUri",
|
||||
};
|
||||
|
||||
/// <summary>True when the equipment row has at least one non-null Identification field.</summary>
|
||||
public static bool HasAnyFields(Equipment equipment)
|
||||
{
|
||||
ArgumentNullException.ThrowIfNull(equipment);
|
||||
return equipment.Manufacturer is not null
|
||||
|| equipment.Model is not null
|
||||
|| equipment.SerialNumber is not null
|
||||
|| equipment.HardwareRevision is not null
|
||||
|| equipment.SoftwareRevision is not null
|
||||
|| equipment.YearOfConstruction is not null
|
||||
|| equipment.AssetLocation is not null
|
||||
|| equipment.ManufacturerUri is not null
|
||||
|| equipment.DeviceManualUri is not null;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Build the Identification sub-folder under <paramref name="equipmentBuilder"/>. No-op
|
||||
/// when every field is null. Returns the sub-folder builder (or null when no-op) so
|
||||
/// callers can attach additional nodes underneath if needed.
|
||||
/// </summary>
|
||||
public static IAddressSpaceBuilder? Build(IAddressSpaceBuilder equipmentBuilder, Equipment equipment)
|
||||
{
|
||||
ArgumentNullException.ThrowIfNull(equipmentBuilder);
|
||||
ArgumentNullException.ThrowIfNull(equipment);
|
||||
|
||||
if (!HasAnyFields(equipment)) return null;
|
||||
|
||||
var folder = equipmentBuilder.Folder(FolderName, FolderName);
|
||||
AddIfPresent(folder, "Manufacturer", DriverDataType.String, equipment.Manufacturer);
|
||||
AddIfPresent(folder, "Model", DriverDataType.String, equipment.Model);
|
||||
AddIfPresent(folder, "SerialNumber", DriverDataType.String, equipment.SerialNumber);
|
||||
AddIfPresent(folder, "HardwareRevision", DriverDataType.String, equipment.HardwareRevision);
|
||||
AddIfPresent(folder, "SoftwareRevision", DriverDataType.String, equipment.SoftwareRevision);
|
||||
AddIfPresent(folder, "YearOfConstruction", DriverDataType.Int32,
|
||||
equipment.YearOfConstruction is null ? null : (object)(int)equipment.YearOfConstruction.Value);
|
||||
AddIfPresent(folder, "AssetLocation", DriverDataType.String, equipment.AssetLocation);
|
||||
AddIfPresent(folder, "ManufacturerUri", DriverDataType.String, equipment.ManufacturerUri);
|
||||
AddIfPresent(folder, "DeviceManualUri", DriverDataType.String, equipment.DeviceManualUri);
|
||||
return folder;
|
||||
}
|
||||
|
||||
private static void AddIfPresent(IAddressSpaceBuilder folder, string name, DriverDataType dataType, object? value)
|
||||
{
|
||||
if (value is null) return;
|
||||
folder.AddProperty(name, dataType, value);
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,158 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Configuration.Entities;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.OpcUa;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Core.Tests.OpcUa;
|
||||
|
||||
[Trait("Category", "Unit")]
|
||||
public sealed class IdentificationFolderBuilderTests
|
||||
{
|
||||
private sealed class RecordingBuilder : IAddressSpaceBuilder
|
||||
{
|
||||
public List<(string BrowseName, string DisplayName)> Folders { get; } = [];
|
||||
public List<(string BrowseName, DriverDataType DataType, object? Value)> Properties { get; } = [];
|
||||
|
||||
public IAddressSpaceBuilder Folder(string browseName, string displayName)
|
||||
{
|
||||
Folders.Add((browseName, displayName));
|
||||
return this; // flat recording — identification fields land in the same bucket
|
||||
}
|
||||
|
||||
public IVariableHandle Variable(string browseName, string displayName, DriverAttributeInfo attributeInfo)
|
||||
=> throw new NotSupportedException("Identification fields use AddProperty, not Variable");
|
||||
|
||||
public void AddProperty(string browseName, DriverDataType dataType, object? value)
|
||||
=> Properties.Add((browseName, dataType, value));
|
||||
}
|
||||
|
||||
private static Equipment EmptyEquipment() => new()
|
||||
{
|
||||
EquipmentId = "EQ-000000000001",
|
||||
DriverInstanceId = "drv-1",
|
||||
UnsLineId = "line-1",
|
||||
Name = "eq-1",
|
||||
MachineCode = "machine_001",
|
||||
};
|
||||
|
||||
private static Equipment FullyPopulatedEquipment() => new()
|
||||
{
|
||||
EquipmentId = "EQ-000000000001",
|
||||
DriverInstanceId = "drv-1",
|
||||
UnsLineId = "line-1",
|
||||
Name = "eq-1",
|
||||
MachineCode = "machine_001",
|
||||
Manufacturer = "Siemens",
|
||||
Model = "S7-1500",
|
||||
SerialNumber = "SN-12345",
|
||||
HardwareRevision = "Rev-A",
|
||||
SoftwareRevision = "Fw-2.3.1",
|
||||
YearOfConstruction = 2023,
|
||||
AssetLocation = "Warsaw-West/Bldg-3",
|
||||
ManufacturerUri = "https://siemens.example",
|
||||
DeviceManualUri = "https://siemens.example/manual",
|
||||
};
|
||||
|
||||
[Fact]
|
||||
public void HasAnyFields_AllNull_ReturnsFalse()
|
||||
{
|
||||
IdentificationFolderBuilder.HasAnyFields(EmptyEquipment()).ShouldBeFalse();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void HasAnyFields_OneNonNull_ReturnsTrue()
|
||||
{
|
||||
var eq = EmptyEquipment();
|
||||
eq.SerialNumber = "SN-1";
|
||||
IdentificationFolderBuilder.HasAnyFields(eq).ShouldBeTrue();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Build_AllNull_ReturnsNull_AndDoesNotEmit_Folder()
|
||||
{
|
||||
var builder = new RecordingBuilder();
|
||||
|
||||
var result = IdentificationFolderBuilder.Build(builder, EmptyEquipment());
|
||||
|
||||
result.ShouldBeNull();
|
||||
builder.Folders.ShouldBeEmpty("no Identification folder when every field is null");
|
||||
builder.Properties.ShouldBeEmpty();
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Build_FullyPopulated_EmitsAllNineFields()
|
||||
{
|
||||
var builder = new RecordingBuilder();
|
||||
|
||||
var result = IdentificationFolderBuilder.Build(builder, FullyPopulatedEquipment());
|
||||
|
||||
result.ShouldNotBeNull();
|
||||
builder.Folders.ShouldContain(f => f.BrowseName == "Identification");
|
||||
builder.Properties.Count.ShouldBe(9);
|
||||
builder.Properties.Select(p => p.BrowseName).ShouldBe(
|
||||
["Manufacturer", "Model", "SerialNumber",
|
||||
"HardwareRevision", "SoftwareRevision",
|
||||
"YearOfConstruction", "AssetLocation",
|
||||
"ManufacturerUri", "DeviceManualUri"],
|
||||
"property order matches decision #139 exactly");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Build_OnlyNonNull_Are_Emitted()
|
||||
{
|
||||
var eq = EmptyEquipment();
|
||||
eq.Manufacturer = "Siemens";
|
||||
eq.SerialNumber = "SN-1";
|
||||
eq.YearOfConstruction = 2024;
|
||||
var builder = new RecordingBuilder();
|
||||
|
||||
IdentificationFolderBuilder.Build(builder, eq);
|
||||
|
||||
builder.Properties.Count.ShouldBe(3, "only the 3 non-null fields are exposed");
|
||||
builder.Properties.Select(p => p.BrowseName).ShouldBe(
|
||||
["Manufacturer", "SerialNumber", "YearOfConstruction"]);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void YearOfConstruction_Maps_Short_To_Int32_DriverDataType()
|
||||
{
|
||||
var eq = EmptyEquipment();
|
||||
eq.YearOfConstruction = 2023;
|
||||
var builder = new RecordingBuilder();
|
||||
|
||||
IdentificationFolderBuilder.Build(builder, eq);
|
||||
|
||||
var prop = builder.Properties.Single(p => p.BrowseName == "YearOfConstruction");
|
||||
prop.DataType.ShouldBe(DriverDataType.Int32);
|
||||
prop.Value.ShouldBe(2023, "short is widened to int for OPC UA Int32 representation");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Build_StringValues_RoundTrip()
|
||||
{
|
||||
var eq = FullyPopulatedEquipment();
|
||||
var builder = new RecordingBuilder();
|
||||
|
||||
IdentificationFolderBuilder.Build(builder, eq);
|
||||
|
||||
builder.Properties.Single(p => p.BrowseName == "Manufacturer").Value.ShouldBe("Siemens");
|
||||
builder.Properties.Single(p => p.BrowseName == "DeviceManualUri").Value.ShouldBe("https://siemens.example/manual");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void FieldNames_Match_Decision139_Exactly()
|
||||
{
|
||||
IdentificationFolderBuilder.FieldNames.ShouldBe(
|
||||
["Manufacturer", "Model", "SerialNumber",
|
||||
"HardwareRevision", "SoftwareRevision",
|
||||
"YearOfConstruction", "AssetLocation",
|
||||
"ManufacturerUri", "DeviceManualUri"]);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void FolderName_Is_Identification()
|
||||
{
|
||||
IdentificationFolderBuilder.FolderName.ShouldBe("Identification");
|
||||
}
|
||||
}
|
||||
Reference in New Issue