perf(opcua): #870 ring-buffer event monitored-item queue
Since #855 condition events are queued to folder event items under the node manager Lock. At a full DiscardOldest queue the SDK's EventQueueHandler dequeues the head of EventMonitoredItemQueue, a List.RemoveAt(0) shift of the whole queue (~1 us/item at QueueSize 1000, ~10 us at 10000). OtOpcUaSdkServer.CreateMonitoredItemQueueFactory now wraps the SDK factory in RingEventQueueFactory: event queues are RingEventMonitoredItemQueue (O(1) discard), data-change queues, durable requests and disposal go to the SDK factory unchanged. A factory set through StandardServer.MonitoredItemQueueFactory is used as-is. The SDK queue is storage only (decompiled 2.0.1): DiscardOldest, overflow-event positions and discarded/overflow counters live in EventQueueHandler, which is unchanged. The ring reproduces QueueSize 0 initial + BadInternalError enqueue, drop-oldest at Count == QueueSize, FIFO dequeue, SetQueueSize keep-newest / keep-oldest, the newest-1000 duplicate window via IsEventRaisedFor, no-op Dispose. RingEventMonitoredItemQueueParityTests drive both queues, and the SDK EventQueueHandler over both factories, with the same random sequences. FolderEventDeliveryPerfTests gains Ring_vs_sdk_event_queue (A/B in one process via the internal OtOpcUaSdkServer.RingEventQueues switch). Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
This commit is contained in:
+25
@@ -0,0 +1,25 @@
|
||||
using Opc.Ua.Server;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests;
|
||||
|
||||
/// <summary>
|
||||
/// Gitea #870: the running server's monitored-item queue factory is <see cref="RingEventQueueFactory"/> (every event
|
||||
/// item's queue is a <see cref="RingEventMonitoredItemQueue"/>; the SDK's <see cref="EventQueueHandler"/> always asks
|
||||
/// the server's factory), and data-change queues are still the SDK's own.
|
||||
/// </summary>
|
||||
public sealed class RingEventQueueWiringTests
|
||||
{
|
||||
[Fact]
|
||||
public async Task The_server_creates_ring_event_queues_and_sdk_data_change_queues()
|
||||
{
|
||||
var ct = TestContext.Current.CancellationToken;
|
||||
await using var rig = await ServerEventRig.StartAsync("RingQueue870", encrypted: false, ct);
|
||||
|
||||
var factory = rig.Server.CurrentInstance.MonitoredItemQueueFactory.ShouldBeOfType<RingEventQueueFactory>();
|
||||
factory.SupportsDurableQueues.ShouldBeFalse();
|
||||
factory.CreateEventQueue(false, 1).ShouldBeOfType<RingEventMonitoredItemQueue>();
|
||||
factory.CreateDataChangeQueue(false, 2).ShouldBeOfType<DataChangeMonitoredItemQueue>();
|
||||
}
|
||||
}
|
||||
Reference in New Issue