fix(adminui): AB forms read/write the factory-bound *Ms duration keys, migrate legacy TimeSpan strings (#576)

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
This commit is contained in:
Joseph Doherty
2026-10-07 23:03:38 -04:00
parent 3d081ad29c
commit bafbcbee7e
10 changed files with 288 additions and 35 deletions
+1 -1
View File
@@ -76,7 +76,7 @@ the driver's `DriverConfig` JSON. Key fields:
- **`Devices`** — one `AbCipDeviceOptions` per PLC (`HostAddress`, `PlcFamily`, optional `DeviceName`, per-device `AllowPacking` / `ConnectionSize` overrides).
- **`Tags`** — pre-declared `AbCipTagDefinition` list; `Members` for UDT fan-out, `SafetyTag` for GuardLogix safety-partition tags.
- **`Probe`** — connectivity-probe `Enabled` / `Interval` / `Timeout` / `ProbeTagPath`. A driver created from the AdminUI starts with the probe **off** (an enabled probe with no tag path only logs a warning); an absent `probe` key in a stored config still means enabled to the driver.
- AdminUI driver forms (AbCip/AbLegacy) overlay only the keys they edit onto the stored JSON, so unmodelled keys survive a save (#576).
- AdminUI driver forms (AbCip/AbLegacy) overlay only the keys they edit onto the stored JSON, so unmodelled keys survive a save (#576). They also write durations as the integer-millisecond keys the factory binds (`timeoutMs`, `alarmPollIntervalMs`, `probe.intervalMs`, `probe.timeoutMs`); a legacy TimeSpan-string key (`timeout`: "00:00:05") is loaded and migrated on save.
- **`Transport`** — absent (default ⇒ `Native`), `Native`, or `Libplctag` (fallback); see [Transport](#transport-transport-option).
- **Discovery** — `EnableControllerBrowse` (`@tags` walk) and `EnableDeclarationOnlyUdtGrouping` (whole-UDT read fast path).
- **Alarms** — `EnableAlarmProjection` + `AlarmPollInterval` for the ALMD projection.