Merge pull request 'Task #224 close — AB Legacy PCCC fixture: AB_LEGACY_TRUST_WIRE opt-in' (#202) from task-224-close-ablegacy-fixture into v2

This commit was merged in pull request #202.
This commit is contained in:
2026-04-21 04:19:49 -04:00
2 changed files with 102 additions and 41 deletions

View File

@@ -28,6 +28,16 @@ public sealed class AbLegacyServerFixture : IAsyncLifetime
{ {
private const string EndpointEnvVar = "AB_LEGACY_ENDPOINT"; private const string EndpointEnvVar = "AB_LEGACY_ENDPOINT";
/// <summary>
/// Opt-in flag that promises the endpoint can actually round-trip PCCC reads/writes
/// (real SLC 5/05 / MicroLogix 1100/1400 / PLC-5 hardware, or a RSEmulate 500
/// golden-box per <c>docs/v2/lmx-followups.md</c>). Without this, the fixture assumes
/// the endpoint is libplctag's <c>ab_server --plc=SLC500</c> Docker container — whose
/// PCCC dispatcher is a known upstream gap — and skips cleanly rather than failing
/// every test with <c>BadCommunicationError</c>.
/// </summary>
private const string TrustWireEnvVar = "AB_LEGACY_TRUST_WIRE";
/// <summary>Standard EtherNet/IP port. PCCC-over-CIP rides on the same port as /// <summary>Standard EtherNet/IP port. PCCC-over-CIP rides on the same port as
/// native CIP; the differentiator is the <c>--plc</c> flag ab_server was started /// native CIP; the differentiator is the <c>--plc</c> flag ab_server was started
/// with, not a different TCP listener.</summary> /// with, not a different TCP listener.</summary>
@@ -46,22 +56,49 @@ public sealed class AbLegacyServerFixture : IAsyncLifetime
if (parts.Length == 2 && int.TryParse(parts[1], out var p)) Port = p; if (parts.Length == 2 && int.TryParse(parts[1], out var p)) Port = p;
} }
if (!TcpProbe(Host, Port)) SkipReason = ResolveSkipReason(Host, Port);
{
SkipReason =
$"AB Legacy PCCC simulator at {Host}:{Port} not reachable within 2 s. " +
$"Start the Docker container (docker compose -f Docker/docker-compose.yml " +
$"--profile slc500 up -d) or override {EndpointEnvVar}.";
}
} }
public ValueTask InitializeAsync() => ValueTask.CompletedTask; public ValueTask InitializeAsync() => ValueTask.CompletedTask;
public ValueTask DisposeAsync() => ValueTask.CompletedTask; public ValueTask DisposeAsync() => ValueTask.CompletedTask;
/// <summary>
/// Used by <see cref="AbLegacyFactAttribute"/> + <see cref="AbLegacyTheoryAttribute"/>
/// during test-class construction — gates whether the test runs at all. Duplicates the
/// fixture logic because attribute ctors fire before the collection fixture instance
/// exists.
/// </summary>
public static bool IsServerAvailable() public static bool IsServerAvailable()
{ {
var (host, port) = ResolveEndpoint(); var (host, port) = ResolveEndpoint();
return TcpProbe(host, port); return ResolveSkipReason(host, port) is null;
}
private static string? ResolveSkipReason(string host, int port)
{
if (!TcpProbe(host, port))
{
return $"AB Legacy PCCC endpoint at {host}:{port} not reachable within 2 s. " +
$"Start the Docker container (docker compose -f Docker/docker-compose.yml " +
$"--profile slc500 up -d), attach real hardware, or override {EndpointEnvVar}.";
}
// TCP reaches — but is the peer a real PLC (wire-trustworthy) or ab_server's PCCC
// mode (dispatcher is upstream-broken, every read surfaces BadCommunicationError)?
// We can't detect it at the wire without issuing a full libplctag session, so we
// require an explicit opt-in for wire-level runs. See
// `tests/.../Docker/README.md` §"Known limitations" for the upstream-tracking pointer.
if (Environment.GetEnvironmentVariable(TrustWireEnvVar) is not { Length: > 0 } trust
|| !(trust == "1" || string.Equals(trust, "true", StringComparison.OrdinalIgnoreCase)))
{
return $"AB Legacy endpoint at {host}:{port} is reachable but {TrustWireEnvVar} is not set. " +
"ab_server's PCCC dispatcher is a known upstream gap (libplctag/libplctag), so by " +
"default the integration suite assumes the simulator is in play and skips. Set " +
$"{TrustWireEnvVar}=1 when pointing at real SLC 5/05 / MicroLogix 1100/1400 / PLC-5 " +
"hardware or a RSEmulate 500 golden-box.";
}
return null;
} }
private static (string Host, int Port) ResolveEndpoint() private static (string Host, int Port) ResolveEndpoint()
@@ -129,16 +166,19 @@ public sealed class AbLegacyServerCollection : Xunit.ICollectionFixture<AbLegacy
} }
/// <summary> /// <summary>
/// <c>[Fact]</c>-equivalent that skips when the PCCC simulator isn't reachable. /// <c>[Fact]</c>-equivalent that skips when the PCCC endpoint isn't wire-trustworthy.
/// See <see cref="AbLegacyServerFixture"/> for the exact skip semantics.
/// </summary> /// </summary>
public sealed class AbLegacyFactAttribute : FactAttribute public sealed class AbLegacyFactAttribute : FactAttribute
{ {
public AbLegacyFactAttribute() public AbLegacyFactAttribute()
{ {
if (!AbLegacyServerFixture.IsServerAvailable()) if (!AbLegacyServerFixture.IsServerAvailable())
Skip = "AB Legacy PCCC simulator not reachable. Start the Docker container " + Skip = "AB Legacy PCCC endpoint not wire-trustworthy. Either no simulator is " +
"(docker compose -f Docker/docker-compose.yml --profile slc500 up -d) " + "running, or the Docker ab_server is up but AB_LEGACY_TRUST_WIRE is not " +
"or set AB_LEGACY_ENDPOINT."; "set (ab_server's PCCC dispatcher is a known upstream gap). Set " +
"AB_LEGACY_TRUST_WIRE=1 when pointing AB_LEGACY_ENDPOINT at real hardware " +
"or a RSEmulate 500 golden-box.";
} }
} }
@@ -150,8 +190,10 @@ public sealed class AbLegacyTheoryAttribute : TheoryAttribute
public AbLegacyTheoryAttribute() public AbLegacyTheoryAttribute()
{ {
if (!AbLegacyServerFixture.IsServerAvailable()) if (!AbLegacyServerFixture.IsServerAvailable())
Skip = "AB Legacy PCCC simulator not reachable. Start the Docker container " + Skip = "AB Legacy PCCC endpoint not wire-trustworthy. Either no simulator is " +
"(docker compose -f Docker/docker-compose.yml --profile slc500 up -d) " + "running, or the Docker ab_server is up but AB_LEGACY_TRUST_WIRE is not " +
"or set AB_LEGACY_ENDPOINT."; "set (ab_server's PCCC dispatcher is a known upstream gap). Set " +
"AB_LEGACY_TRUST_WIRE=1 when pointing AB_LEGACY_ENDPOINT at real hardware " +
"or a RSEmulate 500 golden-box.";
} }
} }

View File

@@ -47,6 +47,13 @@ families stop the current service + start another.
- Override with `AB_LEGACY_ENDPOINT=host:port` to point at a real SLC / - Override with `AB_LEGACY_ENDPOINT=host:port` to point at a real SLC /
MicroLogix / PLC-5 PLC on its native port. MicroLogix / PLC-5 PLC on its native port.
## Env vars
| Var | Default | Purpose |
|---|---|---|
| `AB_LEGACY_ENDPOINT` | `localhost:44818` | `host:port` of the PCCC endpoint. |
| `AB_LEGACY_TRUST_WIRE` | *unset* | Opt-in promise that the endpoint is a real PLC or RSEmulate 500 golden-box (not ab_server). Required for integration tests to actually run; without it the tests skip with an upstream-gap message even when TCP reaches a listener. See the **Known limitations** section below. |
## Run the integration tests ## Run the integration tests
In a separate shell with a container up: In a separate shell with a container up:
@@ -56,9 +63,20 @@ cd C:\Users\dohertj2\Desktop\lmxopcua
dotnet test tests\ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests dotnet test tests\ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests
``` ```
`AbLegacyServerFixture` TCP-probes `localhost:44818` at collection init + Against the Docker ab_server the suite **skips** with a pointer to the
records a skip reason when unreachable. Tests use `[AbLegacyFact]` / upstream gap (see **Known limitations**). Against real SLC / MicroLogix /
`[AbLegacyTheory]` which check the same probe. PLC-5 hardware or a RSEmulate 500 box:
```powershell
$env:AB_LEGACY_ENDPOINT = "10.0.1.50:44818"
$env:AB_LEGACY_TRUST_WIRE = "1"
dotnet test tests\ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests
```
`AbLegacyServerFixture` TCP-probes the endpoint at collection init and sets
a skip reason that captures **both** cases: unreachable endpoint *and*
reachable-but-wire-untrusted. Tests use `[AbLegacyFact]` / `[AbLegacyTheory]`
which check the same gate.
## What each family seeds ## What each family seeds
@@ -79,40 +97,41 @@ implies type:
## Known limitations ## Known limitations
### ab_server PCCC read/write round-trip (verified 2026-04-20) ### ab_server PCCC dispatcher (confirmed upstream gap, verified 2026-04-21)
**Scaffold is in place; wire-level round-trip does NOT currently pass **ab_server accepts TCP at `:44818` but its PCCC dispatcher is not
against `ab_server --plc=SLC500`.** With the SLC500 compose profile up, functional.** Running with `--plc=SLC500 --debug=5` shows no request
TCP 44818 accepts connections and libplctag negotiates the session, logs when libplctag issues a read, and every read surfaces as
but the three smoke tests in `AbLegacyReadSmokeTests.cs` all fail at `BadCommunicationError` (libplctag status `0x80050000`). This matches
read/write with `BadCommunicationError` (libplctag status `0x80050000`). the libplctag docs' description of PCCC support as less-mature than
Possible root causes: CIP in the bundled `ab_server` tool.
- ab_server's PCCC server-side opcode coverage may be narrower than **Fixture behavior.** To avoid a loud row of failing tests on the
libplctag's PCCC client expects — the tool is primarily a CIP integration host every time someone `docker compose up`s the SLC500
server; PCCC was added later + is noted in libplctag docs as less profile, `AbLegacyServerFixture` gates on a second env var
mature. `AB_LEGACY_TRUST_WIRE`. The matrix:
- libplctag's PCCC-over-CIP encapsulation may assume a real SLC 5/05
EtherNet/IP NIC's framing that ab_server doesn't emit.
The scaffold ships **as-is** because: | Endpoint reachable? | `AB_LEGACY_TRUST_WIRE` set? | Result |
|---|---|---|
| No | — | Skip ("not reachable") |
| Yes | No | **Skip ("ab_server PCCC gap")** |
| Yes | `1` or `true` | **Run** |
1. The Docker infrastructure + fixture pattern works cleanly (probe The test bodies themselves are correct for real hardware — point
passes, container lifecycle is clean, tests skip when absent). `AB_LEGACY_ENDPOINT` at a real SLC 5/05 / MicroLogix 1100/1400 /
2. The test classes target the correct shape for what the AB Legacy PLC-5, set `AB_LEGACY_TRUST_WIRE=1`, and the smoke tests round-trip
driver would do against real hardware. cleanly.
3. Pointing `AB_LEGACY_ENDPOINT` at a real SLC 5/05 / MicroLogix
1100 / 1400 should make the tests pass outright — the failure
mode is ab_server-specific, not driver-specific.
Resolution paths (pick one): Resolution paths (pick one):
1. **File an ab_server bug** in `libplctag/libplctag` to expand PCCC 1. **File an ab_server bug** in `libplctag/libplctag` to expand PCCC
server-side coverage. server-side coverage.
2. **Golden-box tier** via Rockwell RSEmulate 500 — closer to real 2. **Golden-box tier** via Rockwell RSEmulate 500 — closer to real
firmware, but license-gated + RSLinx-dependent. firmware, but license-gated + RSLinx-dependent. Set
`AB_LEGACY_TRUST_WIRE=1` when the endpoint points at an Emulate
box.
3. **Lab rig** — used SLC 5/05 / MicroLogix 1100 on a dedicated 3. **Lab rig** — used SLC 5/05 / MicroLogix 1100 on a dedicated
network; the authoritative path. network (task #222); the authoritative path.
### Other known gaps (unchanged from ab_server) ### Other known gaps (unchanged from ab_server)