docs(xmldoc): fill missing XML docs + strip tracking-ID comments across src
v2-ci / build (push) Failing after 41s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
v2-ci / build (push) Failing after 41s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes project bookkeeping IDs (task/tracking refs) from shipped code comments, so the docs read cleanly and CommentChecker is quiet except for known false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc). Doc/comment-only; no logic changed; solution builds clean.
This commit is contained in:
@@ -5,7 +5,7 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.AbLegacy;
|
||||
|
||||
/// <summary>
|
||||
/// AB Legacy (PCCC) driver configuration. One instance supports N devices (SLC 500 /
|
||||
/// MicroLogix / PLC-5 / LogixPccc). Per plan decision #41 AbLegacy ships separately from
|
||||
/// MicroLogix / PLC-5 / LogixPccc). AbLegacy ships separately from
|
||||
/// AbCip because PCCC's file-based addressing (<c>N7:0</c>) and Logix's symbolic addressing
|
||||
/// (<c>Motor1.Speed</c>) pull the abstraction in different directions.
|
||||
/// </summary>
|
||||
|
||||
@@ -40,14 +40,6 @@ public static class AbLegacyEquipmentTagParser
|
||||
if (string.IsNullOrWhiteSpace(address)) return false;
|
||||
var dataType = ReadEnum(root, "dataType", AbLegacyDataType.Int);
|
||||
var deviceHostAddress = ReadString(root, "deviceHostAddress");
|
||||
// Phase 4c #137 — thread the equipment tag's array element count. The canonical
|
||||
// foundation contract: a tag is an ARRAY ⟺ isArray:true. arrayLength (the element
|
||||
// count, ≥1) is honoured ONLY when isArray is the JSON literal true, so a stale
|
||||
// length behind a cleared / absent isArray never produces an orphan array tag that
|
||||
// mismatches its scalar OPC UA node (review C-2). A 1-element array (isArray:true,
|
||||
// arrayLength:1) is a valid [1] array. Clamp to the PCCC file maximum
|
||||
// (AbLegacyArray.MaxElements = 256) so a fat-fingered count can never request a span
|
||||
// larger than a single data file holds. isArray:false / absent → null (scalar).
|
||||
int? arrayLength = null;
|
||||
if (IsArrayFlag(root))
|
||||
{
|
||||
|
||||
@@ -26,6 +26,7 @@ public sealed record AbLegacyPlcFamilyProfile(
|
||||
/// forward-compatibility for device configs authored against a build that predates a new
|
||||
/// family enum member, preferring a safe default over a startup exception.
|
||||
/// </remarks>
|
||||
/// <returns>The libplctag profile defaults for <paramref name="family"/>.</returns>
|
||||
public static AbLegacyPlcFamilyProfile ForFamily(AbLegacyPlcFamily family) => family switch
|
||||
{
|
||||