Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes project bookkeeping IDs (task/tracking refs) from shipped code comments, so the docs read cleanly and CommentChecker is quiet except for known false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc). Doc/comment-only; no logic changed; solution builds clean.
81 lines
3.6 KiB
C#
81 lines
3.6 KiB
C#
namespace ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.PlcFamilies;
|
|
|
|
/// <summary>
|
|
/// Per-family libplctag defaults for PCCC PLCs. SLC 500 / MicroLogix / PLC-5 / LogixPccc
|
|
/// (Logix controller accessed via the PLC-5 compatibility layer — rare but real).
|
|
/// </summary>
|
|
public sealed record AbLegacyPlcFamilyProfile(
|
|
string LibplctagPlcAttribute,
|
|
string DefaultCipPath,
|
|
/// <summary>
|
|
/// Reserved for future array-length clamping. <b>Not currently enforced anywhere in the
|
|
/// driver.</b> The values are approximate upper bounds derived from PCCC packet payload
|
|
/// limits (e.g. SLC 5/05 240 bytes is the PCCC-over-EIP data cap, not a libplctag fragment
|
|
/// limit). Do not rely on this field for sizing decisions until an enforcement point is added.
|
|
/// </summary>
|
|
int MaxTagBytes,
|
|
bool SupportsStringFile,
|
|
bool SupportsLongFile)
|
|
{
|
|
/// <summary>Gets the profile for the specified PLC family.</summary>
|
|
/// <param name="family">The PLC family.</param>
|
|
/// <remarks>
|
|
/// Any unrecognised <paramref name="family"/> value (e.g. an integer cast to the enum, or a
|
|
/// value added to <see cref="AbLegacyPlcFamily"/> before this switch is updated) silently
|
|
/// returns the <see cref="Slc500"/> profile. This is intentional: it preserves
|
|
/// forward-compatibility for device configs authored against a build that predates a new
|
|
/// family enum member, preferring a safe default over a startup exception.
|
|
/// </remarks>
|
|
/// <returns>The libplctag profile defaults for <paramref name="family"/>.</returns>
|
|
public static AbLegacyPlcFamilyProfile ForFamily(AbLegacyPlcFamily family) => family switch
|
|
{
|
|
AbLegacyPlcFamily.Slc500 => Slc500,
|
|
AbLegacyPlcFamily.MicroLogix => MicroLogix,
|
|
AbLegacyPlcFamily.Plc5 => Plc5,
|
|
AbLegacyPlcFamily.LogixPccc => LogixPccc,
|
|
_ => Slc500,
|
|
};
|
|
|
|
public static readonly AbLegacyPlcFamilyProfile Slc500 = new(
|
|
LibplctagPlcAttribute: "slc500",
|
|
DefaultCipPath: "1,0",
|
|
MaxTagBytes: 240, // SLC 5/05 PCCC max packet data
|
|
SupportsStringFile: true, // ST file available SLC 5/04+
|
|
SupportsLongFile: true); // L file available SLC 5/05+
|
|
|
|
public static readonly AbLegacyPlcFamilyProfile MicroLogix = new(
|
|
LibplctagPlcAttribute: "micrologix",
|
|
DefaultCipPath: "", // MicroLogix 1100/1400 use direct EIP, no backplane path
|
|
MaxTagBytes: 232,
|
|
SupportsStringFile: true,
|
|
SupportsLongFile: false); // ML 1100/1200/1400 don't ship L files
|
|
|
|
public static readonly AbLegacyPlcFamilyProfile Plc5 = new(
|
|
LibplctagPlcAttribute: "plc5",
|
|
DefaultCipPath: "1,0",
|
|
MaxTagBytes: 240, // DF1 full-duplex packet limit at 264 bytes, PCCC-over-EIP caps lower
|
|
SupportsStringFile: true,
|
|
SupportsLongFile: false); // PLC-5 predates L files
|
|
|
|
/// <summary>
|
|
/// Logix ControlLogix / CompactLogix accessed through the legacy PCCC compatibility layer.
|
|
/// Rare but real — some legacy HMI integrations address Logix controllers as if they were
|
|
/// PLC-5 via the PCCC-passthrough mechanism.
|
|
/// </summary>
|
|
public static readonly AbLegacyPlcFamilyProfile LogixPccc = new(
|
|
LibplctagPlcAttribute: "logixpccc",
|
|
DefaultCipPath: "1,0",
|
|
MaxTagBytes: 240,
|
|
SupportsStringFile: true,
|
|
SupportsLongFile: true);
|
|
}
|
|
|
|
/// <summary>Which PCCC PLC family the device is.</summary>
|
|
public enum AbLegacyPlcFamily
|
|
{
|
|
Slc500,
|
|
MicroLogix,
|
|
Plc5,
|
|
LogixPccc,
|
|
}
|