docs(xmldoc): fill missing XML docs + strip tracking-ID comments across src
v2-ci / build (push) Failing after 41s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
v2-ci / build (push) Failing after 41s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes project bookkeeping IDs (task/tracking refs) from shipped code comments, so the docs read cleanly and CommentChecker is quiet except for known false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc). Doc/comment-only; no logic changed; solution builds clean.
This commit is contained in:
@@ -27,7 +27,6 @@ public sealed class ProbeCommand : FocasCommandBase
|
||||
public override async ValueTask ExecuteAsync(IConsole console)
|
||||
{
|
||||
ConfigureLogging();
|
||||
// Driver.FOCAS.Cli-003: validate numeric option ranges before any driver work.
|
||||
ValidateOptions();
|
||||
var ct = console.RegisterCancellationHandler();
|
||||
|
||||
@@ -39,9 +38,6 @@ public sealed class ProbeCommand : FocasCommandBase
|
||||
Writable: false);
|
||||
var options = BuildOptions([probeTag]);
|
||||
|
||||
// Driver.FOCAS.Cli-004: `await using` is the sole disposal mechanism — FocasDriver.DisposeAsync
|
||||
// already invokes ShutdownAsync, so a redundant explicit ShutdownAsync(CancellationToken.None)
|
||||
// in a finally block ran shutdown twice. The await-using on the next line is enough.
|
||||
await using var driver = new FocasDriver(options, DriverInstanceId);
|
||||
try
|
||||
{
|
||||
@@ -59,9 +55,6 @@ public sealed class ProbeCommand : FocasCommandBase
|
||||
}
|
||||
finally
|
||||
{
|
||||
// Driver.FOCAS.Cli-006: flush Serilog before process exit so buffered log output
|
||||
// emitted during driver shutdown is not silently dropped (matching DriverCommandBase
|
||||
// docs and every sibling CLI — Modbus / AbCip / AbLegacy / TwinCAT).
|
||||
FlushLogging();
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user