9cad9ed0fc
v2-ci / build (push) Failing after 41s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes project bookkeeping IDs (task/tracking refs) from shipped code comments, so the docs read cleanly and CommentChecker is quiet except for known false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc). Doc/comment-only; no logic changed; solution builds clean.
62 lines
2.5 KiB
C#
62 lines
2.5 KiB
C#
using CliFx.Attributes;
|
|
using CliFx.Infrastructure;
|
|
using ZB.MOM.WW.OtOpcUa.Driver.Cli.Common;
|
|
|
|
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli.Commands;
|
|
|
|
/// <summary>
|
|
/// Probes a Fanuc CNC: opens a FOCAS session + reads one PMC address. Uses the managed
|
|
/// <c>WireFocasClient</c> on TCP:8193. Against an unreachable endpoint it surfaces
|
|
/// <c>BadCommunicationError</c> which is still a useful signal that the CLI wire-up is
|
|
/// correct. Also runs cleanly against the focas-mock Docker fixture in
|
|
/// <c>tests/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.IntegrationTests/Docker/</c>.
|
|
/// </summary>
|
|
[Command("probe", Description = "Verify the CNC is reachable + a sample FOCAS read succeeds.")]
|
|
public sealed class ProbeCommand : FocasCommandBase
|
|
{
|
|
/// <summary>Gets the FOCAS address to probe.</summary>
|
|
[CommandOption("address", 'a', Description =
|
|
"FOCAS address to probe (default R100 — PMC R-file register 100).")]
|
|
public string Address { get; init; } = "R100";
|
|
|
|
/// <summary>Gets the data type to use for the probe read.</summary>
|
|
[CommandOption("type", Description = "Data type (default Int16).")]
|
|
public FocasDataType DataType { get; init; } = FocasDataType.Int16;
|
|
|
|
/// <inheritdoc />
|
|
public override async ValueTask ExecuteAsync(IConsole console)
|
|
{
|
|
ConfigureLogging();
|
|
ValidateOptions();
|
|
var ct = console.RegisterCancellationHandler();
|
|
|
|
var probeTag = new FocasTagDefinition(
|
|
Name: "__probe",
|
|
DeviceHostAddress: HostAddress,
|
|
Address: Address,
|
|
DataType: DataType,
|
|
Writable: false);
|
|
var options = BuildOptions([probeTag]);
|
|
|
|
await using var driver = new FocasDriver(options, DriverInstanceId);
|
|
try
|
|
{
|
|
await driver.InitializeAsync("{}", ct);
|
|
var snapshot = await driver.ReadAsync(["__probe"], ct);
|
|
var health = driver.GetHealth();
|
|
|
|
await console.Output.WriteLineAsync($"CNC: {CncHost}:{CncPort}");
|
|
await console.Output.WriteLineAsync($"Series: {Series}");
|
|
await console.Output.WriteLineAsync($"Health: {health.State}");
|
|
if (health.LastError is { } err)
|
|
await console.Output.WriteLineAsync($"Last error: {err}");
|
|
await console.Output.WriteLineAsync();
|
|
await console.Output.WriteLineAsync(SnapshotFormatter.Format(Address, snapshot[0]));
|
|
}
|
|
finally
|
|
{
|
|
FlushLogging();
|
|
}
|
|
}
|
|
}
|