fix(modbus): review r3 - one address authority (ModbusTagAddressResolution)
N3: a keyless blob carrying the addressResolved marker was served from its string by the driver but saved as HR[0] by the editor model / CSV path. The precedence rule now lives in ONE pure resolver in Driver.Modbus.Contracts (ModbusTagAddressResolution.Classify/Resolve): keys when region+address are both present, else a string-only addressString resolved with the driver's family (refused when it cannot parse), else refused. The marker never decides. Consumers that now ask it instead of restating it: the driver's tag reader (ModbusTagDefinitionFactory.FromTagConfig), the deploy gate (Inspect / DescribeRejection), the editor model (AddressShape / IsStringOnly / HasKeyAddress / ResolveWith, ToJson stamping, Validate), the CSV export cells and the editor hint. The model writes keys only when it loaded them or a field was authored - never defaults it did not resolve (also closes two divergences the new matrix found: malformed-string+marker and non-string addressString were saved as HR[0]). One table-driven test (ModbusAddressAuthorityAgreementTests) runs 15 persisted shapes through driver, deploy gate, model load/save/Validate and the real CSV export->import under all four families; breaking the CSV export or reverting the model to the marker rule fails it. Minors: m1 CSV address cells keep the string+marker while it still describes them (lossless unchanged round trip), drop it when contradicted, and the review grid reports the drop; m2 the pre-lane test uses the real export residual; m3 unmarked string-only + typed-cell case added; m4 stale docs/summary and the unused factory parameter removed. Refs #741 Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
This commit is contained in:
@@ -138,8 +138,9 @@ public sealed class ModbusDriverOptions
|
||||
public bool DisableReadCoalescing { get; init; } = false;
|
||||
|
||||
/// <summary>
|
||||
/// PLC family hint that drives the parser's family-native branch. A tag authored with an
|
||||
/// <c>addressString</c> is resolved with this family at every initialize, so with a non-Generic
|
||||
/// PLC family hint that drives the parser's family-native branch. A STRING-ONLY tag (an
|
||||
/// <c>addressString</c> with no region/address keys — see <see cref="ModbusTagAddressResolution"/>) is
|
||||
/// resolved with this family at every initialize, so with a non-Generic
|
||||
/// value that family's native syntax (DL205 V2000 octal / MELSEC D100) parses to the right
|
||||
/// region + offset. Defaults to <see cref="ModbusFamily.Generic"/> (Modicon / mnemonic grammar).
|
||||
/// Tags authored by region + numeric address are unaffected.
|
||||
|
||||