merge: comms-loss watchdog — DisconnectObserved gets its first production sender (#527)
Closes the defect the #481 live gate surfaced: a driver whose device died mid-run was never detected and never recovered. Live-gated twice on docker-dev. Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
This commit is contained in:
@@ -210,6 +210,38 @@ nothing ever writes a `DriverHostStatus` row (the table was re-created in the v3
|
||||
confirm intent before deleting). The separable `OnHostStatusChanged` event is the useful half. Tracked
|
||||
as Gitea **#521**.
|
||||
|
||||
### Comms-loss detection: `GetHealth()` is load-bearing (Gitea #527, closed)
|
||||
|
||||
Until #527, **`DriverInstanceActor.DisconnectObserved` had no production sender.** The only paths into
|
||||
`Reconnecting` were a failed *initial* connect and an operator's Force Reconnect, so a driver that connected
|
||||
and then lost its device stayed `Connected` indefinitely — publishing Bad for every tag, never
|
||||
re-initialising, and **not recovering when the device returned** (live-confirmed: a Modbus driver against a
|
||||
stopped fixture needed a node restart). `PublishHealthSnapshot` read `GetHealth()` for *reporting only*.
|
||||
|
||||
The `Connected` health tick now runs a watchdog that self-sends `DisconnectObserved` when a driver reports a
|
||||
non-`Healthy` state **and** its `LastSuccessfulRead` has been frozen for 90 s. Things to know before touching it:
|
||||
|
||||
- ⚠️ **The conjunction is the design — "non-Healthy for N polls" is wrong and was the issue's own proposal.**
|
||||
`Degraded` means *connected but some data is bad*, and several drivers write health **per tag inside the
|
||||
read loop** (`ModbusDriver.ReadAsync`), so one unreadable address latches `Degraded` forever against a
|
||||
perfectly reachable device. State-only tripping would reconnect that driver every 90 s indefinitely.
|
||||
`LastSuccessfulRead` is the honest evidence — preserved across `Degraded`/`Faulted` writes, advanced by any
|
||||
success. Each conjunct has a test that goes red when the *other* is deleted.
|
||||
- **The mechanism rests on every driver reaching a non-Healthy state on sustained failure.** Surveyed across
|
||||
all 12: nine poll drivers via `Degraded`, MQTT via live connection state, Galaxy via its reconnect
|
||||
supervisor. `CalculationDriver` reports `Healthy` while running and so can never trip — correct, as it has
|
||||
no transport. Re-check this if a new driver lands.
|
||||
- ⚠️ **The reconnect retry MUST tear down before re-initialising.** `ModbusDriver` (`_transport`) and
|
||||
`MqttDriver` (`_connection`) overwrite an `IAsyncDisposable` field inside `InitializeAsync` without
|
||||
disposing the old one, so re-initialising without `ShutdownAsync` leaks a socket per attempt — ~360 for an
|
||||
hour-long outage at the 10 s retry interval. Latent while only a manual Force Reconnect reached this path.
|
||||
- The threshold is hardcoded (`DefaultCommsLossTimeout`), matching `HealthPollInterval` /
|
||||
`DefaultReconnectInterval`. Unlike the #523 drift detector this generates **no** traffic on a healthy
|
||||
system — it is a local `GetHealth()` read, and only reaches the network once a driver has already stopped
|
||||
reading.
|
||||
|
||||
See `docs/DriverLifecycle.md` §"The comms-loss watchdog".
|
||||
|
||||
## mxaccessgw
|
||||
|
||||
The gateway lives in a sibling repo at `~/Desktop/MxAccessGateway/` (`mxaccessgw` — see [Related Projects](#related-projects-scadaproj-umbrella)). See `docs/v2/Galaxy.ParityRig.md` for the gw setup recipe (build, API key provisioning via `apikey create-key`, env-var overrides for HTTP/2 cleartext + worker path). The gw's MXAccess Toolkit reference (its `gateway.md`) is the canonical MxAccess API doc; the standalone `mxaccess_documentation.md` previously kept in this repo retired in PR 7.3.
|
||||
|
||||
+16
-9
@@ -183,15 +183,22 @@ Two things worth knowing before changing this:
|
||||
and is the correct reading of "this input's source is unreachable", but it is a behaviour change beyond
|
||||
scripted alarms.
|
||||
|
||||
⚠️ **The signal this hangs off does not currently fire for a mid-run device loss — see #527.** The #481 live
|
||||
gate on docker-dev found that `DriverInstanceActor.DisconnectObserved` has **no production sender**: the only
|
||||
paths into `Reconnecting` are a failed *initial* connect and an operator Force Reconnect. A Modbus driver
|
||||
whose fixture was stopped stayed `Connected` for >10 minutes publishing per-tag Bad, and did not recover when
|
||||
the fixture came back until the node was restarted. So the fan-out above — and the native `#477` Layer 2
|
||||
annotation it mirrors — are correctly wired to a signal that a dying device never raises. What partially
|
||||
covers the gap today is that Modbus publishes Bad *per tag* rather than going silent, so #478 Layer 3 does
|
||||
carry Bad into scripted input quality for that driver; that is a per-driver accident, not a guarantee, and it
|
||||
does nothing for native conditions or for recovery. Closing #527 is what makes this path reachable.
|
||||
**The signal this hangs off now fires for a mid-run device loss (#527, closed).** The #481 live gate on
|
||||
docker-dev found that `DriverInstanceActor.DisconnectObserved` had **no production sender**: the only paths
|
||||
into `Reconnecting` were a failed *initial* connect and an operator Force Reconnect. A Modbus driver whose
|
||||
fixture was stopped stayed `Connected` for >10 minutes publishing per-tag Bad, and did not recover when the
|
||||
fixture came back until the node was restarted. So the fan-out above — and the native #477 Layer 2
|
||||
annotation it mirrors — were correctly wired to a signal that a dying device never raised. #527 added the
|
||||
comms-loss watchdog on the Connected health tick, which self-sends `DisconnectObserved` once a driver has
|
||||
gone 90 s without a successful read *while* reporting itself non-Healthy. See
|
||||
[`DriverLifecycle.md`](DriverLifecycle.md) §"The comms-loss watchdog" for why the trip condition is that
|
||||
conjunction and not simply "non-Healthy for N polls" — the naive rule would reconnect a healthy device's
|
||||
driver every 90 s forever whenever one authored address is unreadable.
|
||||
|
||||
Note the partial cover that existed before, because it explains why *some* of this appeared to work: Modbus
|
||||
publishes Bad *per tag* rather than going silent, so #478 Layer 3 did carry Bad into scripted input quality
|
||||
for that driver. That was a per-driver accident, not a guarantee, and it did nothing for native conditions
|
||||
or for recovery.
|
||||
|
||||
**Cold start vs. a driver reporting Bad (#478 Finding 3, closed by #481).** `WorstInputStatus` used to skip
|
||||
every input whose *value* was null as "no data yet". A comms-lost driver produces exactly that shape — Bad
|
||||
|
||||
@@ -219,6 +219,57 @@ So a driver whose `InitializeAsync` disposes anything on its failure path must b
|
||||
`MTConnectDriver` does today, because it is the only one that tears down inside a `catch`. The
|
||||
shutdown paths deliberately keep the single trailing write.
|
||||
|
||||
### The comms-loss watchdog (Gitea #527) — `GetHealth()` is now load-bearing
|
||||
|
||||
`GetHealth()` used to be **reporting-only**: `DriverInstanceActor.PublishHealthSnapshot` read it every 30 s
|
||||
and forwarded it to the AdminUI, and nothing ever acted on a driver that reported itself unhealthy. That
|
||||
left `DisconnectObserved` with **no production sender at all** — the only paths into `Reconnecting` were a
|
||||
failed *initial* connect and an operator's Force Reconnect. A driver that connected and then lost its
|
||||
device stayed `Connected` forever: publishing Bad for every tag, never re-initialising, and **not
|
||||
recovering when the device came back** (live-confirmed against a stopped Modbus fixture, which needed a
|
||||
node restart). Both comms-loss quality paths — #477's native-condition annotation and #481's
|
||||
scripted-alarm input fan-out — hang off `ConnectivityChanged`, so both were wired to a signal that never
|
||||
fired.
|
||||
|
||||
The `Connected`-state health tick now also evaluates a watchdog, and self-sends `DisconnectObserved` when
|
||||
**both** of these hold:
|
||||
|
||||
1. the driver reports a state other than `Healthy`, **and**
|
||||
2. `DriverHealth.LastSuccessfulRead` has not advanced for `DefaultCommsLossTimeout` (90 s = three ticks),
|
||||
measured from the Connected entry when the driver has never reported a successful read.
|
||||
|
||||
**The conjunction is the whole design, and "non-Healthy for N polls" is the wrong rule.** `Degraded` means
|
||||
*connected but some data is bad* — the enum says so. Several drivers publish health **per tag inside their
|
||||
read loop** (`ModbusDriver.ReadAsync` writes `Healthy` or `Degraded` once per reference), so a single
|
||||
unreadable address leaves the driver latched `Degraded` whenever it happens to be read last, indefinitely,
|
||||
against a device that is perfectly reachable. A state-only watchdog would tear that driver down every 90 s
|
||||
forever — strictly worse than the bug it fixes. `LastSuccessfulRead` is the honest liveness evidence: every
|
||||
driver advances it on any successful read and *preserves* it across `Degraded`/`Faulted` writes, so one bad
|
||||
tag among good ones keeps it moving while a device that is genuinely gone freezes it. The state check is
|
||||
still needed as the second conjunct, because a `Healthy` driver with nothing subscribed legitimately never
|
||||
reads and must not be declared dead for being idle. Both halves are pinned by their own test in
|
||||
`DriverInstanceActorCommsLossWatchdogTests`, each of which goes red when the *other* conjunct is deleted.
|
||||
|
||||
Two consequences worth knowing:
|
||||
|
||||
- **`CalculationDriver` can never trip it, correctly.** It reports `Healthy` whenever it is running and has
|
||||
no transport to be degraded about. Every other driver reaches a non-Healthy state on sustained failure:
|
||||
the nine poll drivers via `Degraded`, MQTT via its live connection state, Galaxy via its reconnect
|
||||
supervisor. This was surveyed across all 12 before relying on it — it is the assumption the whole
|
||||
mechanism rests on.
|
||||
- **A device that accepts a connection but serves no data will cycle**, reconnecting once per threshold.
|
||||
That is the correct reading of a broken device, it is rate-limited, and it is visible in the health
|
||||
snapshot's error count — but do not mistake it for a bug when reading logs.
|
||||
|
||||
**The reconnect retry now tears down before re-initialising.** `Reconnecting`'s `RetryConnect` calls
|
||||
`ShutdownAsync` before `InitializeAsync` — the sequence every driver's own `ReinitializeAsync` already
|
||||
uses — because several drivers **overwrite** an `IAsyncDisposable` transport field inside `InitializeAsync`
|
||||
without disposing the previous one (`ModbusDriver._transport`, `MqttDriver._connection`). Re-initialising
|
||||
without a teardown leaks one socket per attempt. That was latent while only a manual Force Reconnect
|
||||
re-entered this path; the watchdog makes it automatic and unbounded, so a device down for an hour would
|
||||
have leaked ~360 transports at the 10 s retry interval. The shutdown is best-effort: a driver that throws
|
||||
on it still gets its initialise attempt.
|
||||
|
||||
---
|
||||
|
||||
## IDriverConfigEditor — custom AdminUI config editor (plug-point)
|
||||
|
||||
@@ -141,6 +141,23 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
/// <summary>Interval between periodic health-poll heartbeats sent to the snapshot store.</summary>
|
||||
public static readonly TimeSpan HealthPollInterval = TimeSpan.FromSeconds(30);
|
||||
|
||||
/// <summary>
|
||||
/// How long a Connected driver may go without a single successful read — while also reporting
|
||||
/// itself non-Healthy — before the actor declares comms lost (Gitea #527). Evaluated on the
|
||||
/// existing <see cref="HealthPollInterval"/> tick, so the effective detection granularity is
|
||||
/// 30 s and the worst-case detection latency is this value plus one tick.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// 90 s = three health-poll ticks. Long enough that a device answering slowly under load is not
|
||||
/// torn down, short enough that an operator watching a dead PLC sees it inside two minutes.
|
||||
/// Hardcoded rather than exposed in appsettings, matching <see cref="HealthPollInterval"/> and
|
||||
/// <see cref="DefaultReconnectInterval"/>. Unlike the periodic drift-detector removed by Gitea
|
||||
/// #523, this generates <b>no</b> outbound traffic on a healthy system: the watchdog is a local
|
||||
/// read of <see cref="IDriver.GetHealth"/>, and it only reaches the network once a driver has
|
||||
/// already stopped reading successfully.
|
||||
/// </remarks>
|
||||
public static readonly TimeSpan DefaultCommsLossTimeout = TimeSpan.FromSeconds(90);
|
||||
|
||||
private readonly IDriver _driver;
|
||||
|
||||
/// <summary>Phase 6.1 resilience seam: every guarded driver-capability call this actor makes is
|
||||
@@ -158,6 +175,14 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
|
||||
private readonly TimeSpan _healthPollInterval;
|
||||
|
||||
/// <summary>Comms-loss watchdog threshold (#527); <see cref="TimeSpan.Zero"/> or negative disables it.</summary>
|
||||
private readonly TimeSpan _commsLossTimeout;
|
||||
|
||||
/// <summary>When the actor last entered <c>Connected</c>. The comms-loss watchdog's baseline for a
|
||||
/// driver that has never reported a successful read, so "connected but never read anything" is
|
||||
/// measurable rather than indefinitely undefined.</summary>
|
||||
private DateTime _connectedSinceUtc;
|
||||
|
||||
private readonly ILoggingAdapter _log = Context.GetLogger();
|
||||
private string? _currentConfigJson;
|
||||
|
||||
@@ -229,6 +254,9 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
/// <param name="healthPollInterval">Optional period of the health-poll heartbeat, which also drives the
|
||||
/// subscription reconcile (<see cref="ReconcileSubscription"/>); defaults to
|
||||
/// <see cref="HealthPollInterval"/>. Exists so a test can drive the reconcile without waiting 30 s.</param>
|
||||
/// <param name="commsLossTimeout">Optional comms-loss watchdog threshold (#527); defaults to
|
||||
/// <see cref="DefaultCommsLossTimeout"/>. <see cref="TimeSpan.Zero"/> disables the watchdog — used by
|
||||
/// tests that need a Connected driver to stay Connected while reporting non-Healthy.</param>
|
||||
/// <returns>A <see cref="Akka.Actor.Props"/> instance configured to create the wrapped <see cref="DriverInstanceActor"/>.</returns>
|
||||
public static Props Props(
|
||||
IDriver driver,
|
||||
@@ -237,7 +265,8 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
IDriverHealthPublisher? healthPublisher = null,
|
||||
string? clusterId = null,
|
||||
IDriverCapabilityInvoker? invoker = null,
|
||||
TimeSpan? healthPollInterval = null) =>
|
||||
TimeSpan? healthPollInterval = null,
|
||||
TimeSpan? commsLossTimeout = null) =>
|
||||
Akka.Actor.Props.Create(() => new DriverInstanceActor(
|
||||
driver,
|
||||
reconnectInterval ?? DefaultReconnectInterval,
|
||||
@@ -245,7 +274,8 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
healthPublisher ?? NullDriverHealthPublisher.Instance,
|
||||
clusterId ?? string.Empty,
|
||||
invoker,
|
||||
healthPollInterval));
|
||||
healthPollInterval,
|
||||
commsLossTimeout));
|
||||
|
||||
/// <summary>
|
||||
/// Returns true when the driver should boot in DEV-STUB mode based on host platform and
|
||||
@@ -278,6 +308,8 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
/// defaults to <see cref="NullDriverCapabilityInvoker"/> (pass-through) when null.</param>
|
||||
/// <param name="healthPollInterval">Period of the health-poll heartbeat, which also drives the
|
||||
/// subscription reconcile; defaults to <see cref="HealthPollInterval"/> when null.</param>
|
||||
/// <param name="commsLossTimeout">Comms-loss watchdog threshold (#527); defaults to
|
||||
/// <see cref="DefaultCommsLossTimeout"/> when null, and is disabled when zero or negative.</param>
|
||||
public DriverInstanceActor(
|
||||
IDriver driver,
|
||||
TimeSpan reconnectInterval,
|
||||
@@ -285,7 +317,8 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
IDriverHealthPublisher? healthPublisher = null,
|
||||
string? clusterId = null,
|
||||
IDriverCapabilityInvoker? invoker = null,
|
||||
TimeSpan? healthPollInterval = null)
|
||||
TimeSpan? healthPollInterval = null,
|
||||
TimeSpan? commsLossTimeout = null)
|
||||
{
|
||||
_driver = driver;
|
||||
_invoker = invoker ?? NullDriverCapabilityInvoker.Instance;
|
||||
@@ -294,6 +327,7 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
_healthPublisher = healthPublisher ?? NullDriverHealthPublisher.Instance;
|
||||
_reconnectInterval = reconnectInterval;
|
||||
_healthPollInterval = healthPollInterval ?? HealthPollInterval;
|
||||
_commsLossTimeout = commsLossTimeout ?? DefaultCommsLossTimeout;
|
||||
OtOpcUaTelemetry.DriverInstanceLifecycle.Add(1,
|
||||
new KeyValuePair<string, object?>("event", startStubbed ? "spawn_stub" : "spawn"),
|
||||
new KeyValuePair<string, object?>("driver_type", driver.DriverType));
|
||||
@@ -403,6 +437,10 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
// non-Good "waiting for initial data" quality at materialise, and this is what confirms them Good.
|
||||
Context.Parent.Tell(new ConnectivityChanged(_driverInstanceId, Connected: true));
|
||||
|
||||
// #527 — baseline for the comms-loss watchdog. Re-stamped on every Connected entry so a driver that
|
||||
// reconnects but never manages a read is measured from THIS connect, not from a stale earlier one.
|
||||
_connectedSinceUtc = DateTime.UtcNow;
|
||||
|
||||
ReceiveAsync<ApplyDelta>(HandleApplyDeltaAsync);
|
||||
Receive<DisconnectObserved>(msg =>
|
||||
{
|
||||
@@ -456,11 +494,76 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
Receive<HostStatusRaised>(_ => PublishHealthSnapshot());
|
||||
Receive<HealthPollTick>(_ =>
|
||||
{
|
||||
PublishHealthSnapshot();
|
||||
// One GetHealth observation feeds both the snapshot publish and the watchdog — reading it
|
||||
// twice would let the two disagree about the same tick.
|
||||
var health = PublishHealthSnapshot();
|
||||
EvaluateCommsLossWatchdog(health);
|
||||
ReconcileSubscription();
|
||||
});
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Gitea #527 — the comms-loss watchdog. Declares a Connected driver disconnected once it has gone
|
||||
/// <see cref="_commsLossTimeout"/> without a single successful read <b>while also</b> reporting
|
||||
/// itself non-Healthy, by self-sending <see cref="DisconnectObserved"/>.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para>
|
||||
/// <b>Why this exists.</b> <see cref="DisconnectObserved"/> had no production sender at all. The only
|
||||
/// ways into <c>Reconnecting</c> were a failed <em>initial</em> connect and an operator's Force
|
||||
/// Reconnect, so a driver that connected successfully and then lost its device stayed Connected
|
||||
/// forever: it published Bad for every tag, never re-initialised, and did not recover when the device
|
||||
/// came back — live-confirmed against a stopped Modbus fixture, which needed a node restart. Both
|
||||
/// comms-loss quality paths (#477 native conditions, #481 scripted-alarm inputs) hang off
|
||||
/// <see cref="ConnectivityChanged"/>, so both were wired to a signal that never fired.
|
||||
/// <c>OpcUaClientDriver</c>'s own reconnect-exhausted branch already assumed this mechanism existed
|
||||
/// ("the Core never learns it must offer an operator reinitialize") — it did not.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// <b>Why the trip condition is a conjunction, and NOT simply "non-Healthy for N polls".</b>
|
||||
/// <see cref="DriverState.Degraded"/> means <em>connected but some data is bad</em> — the enum says
|
||||
/// so. Several drivers publish health per-tag inside their read loop (<c>ModbusDriver.ReadAsync</c>
|
||||
/// writes Healthy or Degraded once per reference), so a single unreadable address leaves the driver
|
||||
/// Degraded whenever it happens to be the last tag read, indefinitely, against a perfectly healthy
|
||||
/// device. Tripping on state alone would tear that driver down every watchdog period forever —
|
||||
/// strictly worse than the bug being fixed.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// <see cref="DriverHealth.LastSuccessfulRead"/> is the honest liveness evidence: every driver
|
||||
/// advances it on any successful read and <em>preserves</em> it across Degraded/Faulted writes. One
|
||||
/// bad tag among good ones keeps it moving; a device that is genuinely gone freezes it. The state
|
||||
/// check is still required as the second conjunct, because a Healthy driver with nothing subscribed
|
||||
/// legitimately never reads at all and must not be declared dead for being idle.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// <b>Drivers this cannot fire for, by construction.</b> <c>CalculationDriver</c> reports Healthy
|
||||
/// whenever it is running (it has no transport to be degraded about), so it never trips — correct,
|
||||
/// since there is nothing to reconnect to. Every other driver in the tree reaches a non-Healthy
|
||||
/// state on sustained failure: the nine poll drivers via Degraded, MQTT via its live connection
|
||||
/// state, Galaxy via its reconnect supervisor.
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
/// <param name="health">The health observed on this tick, or null when <see cref="IDriver.GetHealth"/>
|
||||
/// threw — a failed observation is not evidence of comms loss, so it never advances the watchdog.</param>
|
||||
private void EvaluateCommsLossWatchdog(DriverHealth? health)
|
||||
{
|
||||
if (_commsLossTimeout <= TimeSpan.Zero) return;
|
||||
if (health is not { } observed) return;
|
||||
if (observed.State == DriverState.Healthy) return;
|
||||
|
||||
// A driver that has never reported a successful read is measured from the current Connected entry.
|
||||
var lastEvidence = observed.LastSuccessfulRead ?? _connectedSinceUtc;
|
||||
var silence = DateTime.UtcNow - lastEvidence;
|
||||
if (silence < _commsLossTimeout) return;
|
||||
|
||||
_log.Warning(
|
||||
"DriverInstance {Id}: no successful read for {Silence} while reporting {State} ({Error}) — " +
|
||||
"declaring comms lost and reconnecting",
|
||||
_driverInstanceId, silence, observed.State, observed.LastError ?? "no error reported");
|
||||
Self.Tell(new DisconnectObserved(
|
||||
$"no successful read for {silence.TotalSeconds:F0}s while reporting {observed.State}"));
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Periodic desired-vs-actual subscription reconcile (#488), riding the existing <c>health-poll</c>
|
||||
/// tick. While Connected, a driver that has a desired subscription set but no live handle is
|
||||
@@ -514,7 +617,8 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
// (a comms-lost driver emits no alarm events, so this is the ONLY signal that the source is unreachable).
|
||||
Context.Parent.Tell(new ConnectivityChanged(_driverInstanceId, Connected: false));
|
||||
|
||||
Receive<RetryConnect>(_ => InitializeAsync(_currentConfigJson ?? "{}"));
|
||||
// #527 — tear the dead transport down before re-initialising, or every retry leaks one.
|
||||
Receive<RetryConnect>(_ => InitializeAsync(_currentConfigJson ?? "{}", teardownFirst: true));
|
||||
// Fast-fail writes while reconnecting (same reason as Connecting — avoids the 8s host Ask
|
||||
// timeout on an inbound write to a transiently-down driver). Synchronous Receive.
|
||||
Receive<WriteAttribute>(_ =>
|
||||
@@ -562,16 +666,45 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
Timers.StartPeriodicTimer("retry-connect", RetryConnect.Instance, _reconnectInterval);
|
||||
}
|
||||
|
||||
private void InitializeAsync(string driverConfigJson)
|
||||
/// <param name="driverConfigJson">The config blob to initialise the driver with.</param>
|
||||
/// <param name="teardownFirst">
|
||||
/// When true, <see cref="IDriver.ShutdownAsync"/> is awaited before <see cref="IDriver.InitializeAsync"/>
|
||||
/// — the sequence every driver's own <c>ReinitializeAsync</c> uses. Set on the <c>Reconnecting</c>
|
||||
/// retry path (#527), because several drivers <em>overwrite</em> their transport field in
|
||||
/// <c>InitializeAsync</c> without disposing the previous one: <c>ModbusDriver</c> assigns
|
||||
/// <c>_transport = _transportFactory(...)</c> and <c>MqttDriver</c> assigns <c>_connection</c>, both
|
||||
/// over an <see cref="IAsyncDisposable"/>. Re-initialising without tearing down therefore leaks one
|
||||
/// socket (and, for Modbus, a poll engine) per attempt. That was latent while nothing but an
|
||||
/// operator's Force Reconnect ever re-entered this path; the watchdog makes it automatic and
|
||||
/// unbounded — a device down for an hour would leak ~360 transports at the 10 s retry interval.
|
||||
/// Best-effort and never fatal: a driver that throws on shutdown still gets its initialise attempt.
|
||||
/// </param>
|
||||
private void InitializeAsync(string driverConfigJson, bool teardownFirst = false)
|
||||
{
|
||||
_currentConfigJson = driverConfigJson;
|
||||
var generation = ++_initGeneration;
|
||||
var self = Self;
|
||||
var log = _log;
|
||||
var driverInstanceId = _driverInstanceId;
|
||||
var driver = _driver;
|
||||
_ = Task.Run(async () =>
|
||||
{
|
||||
try
|
||||
{
|
||||
await _driver.InitializeAsync(driverConfigJson, CancellationToken.None);
|
||||
if (teardownFirst)
|
||||
{
|
||||
try
|
||||
{
|
||||
await driver.ShutdownAsync(CancellationToken.None);
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
log.Warning(ex,
|
||||
"DriverInstance {Id}: ShutdownAsync threw before a reconnect attempt; " +
|
||||
"initialising anyway", driverInstanceId);
|
||||
}
|
||||
}
|
||||
await driver.InitializeAsync(driverConfigJson, CancellationToken.None);
|
||||
self.Tell(new InitializeSucceeded(generation));
|
||||
}
|
||||
catch (Exception ex)
|
||||
@@ -1006,11 +1139,16 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
/// every 30s when nothing has changed. Newly-joined SignalR clients still get the current
|
||||
/// snapshot via <c>DriverStatusHub.JoinDriver</c> which reads the store directly.
|
||||
/// </summary>
|
||||
private void PublishHealthSnapshot()
|
||||
/// <returns>The health observed on this call, or null when <see cref="IDriver.GetHealth"/> threw.
|
||||
/// Returned so the caller can reuse the same observation — the #527 comms-loss watchdog rides this
|
||||
/// call rather than polling the driver a second time and risking a different answer.</returns>
|
||||
private DriverHealth? PublishHealthSnapshot()
|
||||
{
|
||||
DriverHealth? observed = null;
|
||||
try
|
||||
{
|
||||
var health = _driver.GetHealth();
|
||||
observed = health;
|
||||
var errorCount = ErrorCount5Min();
|
||||
var hostStatuses = CurrentHostStatuses();
|
||||
// _rediscoveryNeededUtc is PART OF THE FINGERPRINT on purpose. A rediscovery raise on an
|
||||
@@ -1027,7 +1165,7 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
var fingerprint = (health.State, health.LastSuccessfulRead, health.LastError, errorCount,
|
||||
_rediscoveryNeededUtc, HostStatusDigest(hostStatuses));
|
||||
if (_lastPublishedFingerprint is { } prev && prev.Equals(fingerprint))
|
||||
return;
|
||||
return observed;
|
||||
_lastPublishedFingerprint = fingerprint;
|
||||
_healthPublisher.Publish(
|
||||
_clusterId, _driverInstanceId, health, errorCount, _rediscoveryNeededUtc, _rediscoveryReason,
|
||||
@@ -1037,6 +1175,7 @@ public sealed class DriverInstanceActor : ReceiveActor, IWithTimers
|
||||
{
|
||||
_log.Warning(ex, "DriverInstance {Id}: GetHealth threw during health publish; skipping", _driverInstanceId);
|
||||
}
|
||||
return observed;
|
||||
}
|
||||
|
||||
/// <summary>Order-insensitive value digest of a host-status list for the publish fingerprint. Null in,
|
||||
|
||||
+330
@@ -0,0 +1,330 @@
|
||||
using Akka.Actor;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
using ZB.MOM.WW.OtOpcUa.Runtime.Drivers;
|
||||
using ZB.MOM.WW.OtOpcUa.Runtime.Tests.Harness;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Runtime.Tests.Drivers;
|
||||
|
||||
/// <summary>
|
||||
/// Gitea #527 — the comms-loss watchdog that gives <see cref="DriverInstanceActor.DisconnectObserved"/>
|
||||
/// its first production sender.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para>
|
||||
/// <b>The defect.</b> Nothing in <c>src/</c> ever sent <c>DisconnectObserved</c>. A driver that
|
||||
/// connected and then lost its device stayed <c>Connected</c> indefinitely — publishing Bad for
|
||||
/// every tag, never re-initialising, and not recovering when the device returned. Live-confirmed
|
||||
/// against a stopped Modbus fixture, which needed a node restart.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// <b>What these tests are really pinning is the trip CONDITION, not the plumbing.</b> The obvious
|
||||
/// design — "non-Healthy for N consecutive polls" — is wrong, and
|
||||
/// <see cref="A_degraded_driver_that_is_still_reading_successfully_is_left_alone"/> is the test that
|
||||
/// says so. <see cref="DriverState.Degraded"/> means <i>connected but some data is bad</i>, and
|
||||
/// several drivers write health per-tag inside their read loop, so one unreadable address can leave
|
||||
/// a perfectly healthy device's driver Degraded forever. Tripping on state alone would reconnect
|
||||
/// that driver every 90 s in production — worse than the bug being fixed. The conjunction with a
|
||||
/// frozen <see cref="DriverHealth.LastSuccessfulRead"/> is what makes the signal honest, and
|
||||
/// <see cref="An_idle_healthy_driver_with_a_stale_last_read_is_left_alone"/> pins the other half.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// Every absence assertion carries a positive control — a proven number of health-poll ticks
|
||||
/// actually processed (<see cref="HealthControlledStubDriver.HealthReadCount"/>) — so "the watchdog
|
||||
/// did not fire" can never pass merely because nothing ran.
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
public sealed class DriverInstanceActorCommsLossWatchdogTests : RuntimeActorTestBase
|
||||
{
|
||||
private static readonly TimeSpan FastPoll = TimeSpan.FromMilliseconds(50);
|
||||
private static readonly TimeSpan FastTimeout = TimeSpan.FromMilliseconds(250);
|
||||
|
||||
/// <summary>Drives the actor to Connected and returns once the connect has been announced.</summary>
|
||||
private (IActorRef Actor, Akka.TestKit.TestProbe Parent) ConnectDriver(
|
||||
HealthControlledStubDriver driver,
|
||||
TimeSpan? commsLossTimeout = null,
|
||||
TimeSpan? reconnectInterval = null)
|
||||
{
|
||||
var parent = CreateTestProbe();
|
||||
var actor = parent.ChildActorOf(DriverInstanceActor.Props(
|
||||
driver,
|
||||
reconnectInterval: reconnectInterval ?? TimeSpan.FromSeconds(30),
|
||||
healthPollInterval: FastPoll,
|
||||
commsLossTimeout: commsLossTimeout ?? FastTimeout));
|
||||
|
||||
actor.Tell(new DriverInstanceActor.InitializeRequested("{}"));
|
||||
// Connected entry announces Connected=true; consuming it here leaves the probe holding only
|
||||
// whatever the watchdog does (or does not) send next.
|
||||
parent.ExpectMsg<DriverInstanceActor.ConnectivityChanged>(TimeSpan.FromSeconds(3))
|
||||
.Connected.ShouldBeTrue();
|
||||
return (actor, parent);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The core of #527: a Connected driver whose device has gone away — non-Healthy, and no successful
|
||||
/// read since well before the threshold — is declared disconnected and announces comms loss to the
|
||||
/// host, which is the signal #477 and #481 both hang off.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void A_connected_driver_that_stops_reading_successfully_is_declared_disconnected()
|
||||
{
|
||||
var driver = new HealthControlledStubDriver
|
||||
{
|
||||
// The live shape: reads fail, the driver reports Degraded, and LastSuccessfulRead is frozen
|
||||
// at the instant the device died.
|
||||
Health = new DriverHealth(DriverState.Degraded, DateTime.UtcNow.AddMinutes(-5), "socket timeout"),
|
||||
};
|
||||
var (_, parent) = ConnectDriver(driver);
|
||||
|
||||
parent.ExpectMsg<DriverInstanceActor.ConnectivityChanged>(TimeSpan.FromSeconds(3))
|
||||
.Connected.ShouldBeFalse();
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The falsifying control for the trip condition, and the reason it is not "non-Healthy for N polls".
|
||||
/// This driver is <b>permanently Degraded</b> — modelling one unreadable address among many, which
|
||||
/// <c>ModbusDriver.ReadAsync</c> leaves latched whenever the bad tag is read last — but it is still
|
||||
/// reading successfully, so <c>LastSuccessfulRead</c> keeps advancing. It must be left alone.
|
||||
/// A state-only watchdog would tear this driver down on every threshold, forever.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void A_degraded_driver_that_is_still_reading_successfully_is_left_alone()
|
||||
{
|
||||
var driver = new HealthControlledStubDriver
|
||||
{
|
||||
// Recomputed per call: Degraded, but LastSuccessfulRead is always fresh.
|
||||
HealthFactory = () => new DriverHealth(DriverState.Degraded, DateTime.UtcNow, "one bad tag"),
|
||||
};
|
||||
var (_, parent) = ConnectDriver(driver);
|
||||
|
||||
// Positive control: prove the watchdog genuinely ran, many times, over a span far longer than the
|
||||
// trip threshold. Without this the absence assertion below would pass against a watchdog that
|
||||
// never executed at all.
|
||||
AwaitCondition(
|
||||
() => driver.HealthReadCount >= 12,
|
||||
TimeSpan.FromSeconds(5),
|
||||
"health-poll ticks did not run — the absence assertion below would be vacuous");
|
||||
driver.ObservedSpan.ShouldBeGreaterThan(FastTimeout, "the observation window never exceeded the trip threshold");
|
||||
|
||||
parent.ExpectNoMsg(TimeSpan.FromMilliseconds(200));
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The other conjunct. A Healthy driver with nothing subscribed legitimately never reads, so its
|
||||
/// <c>LastSuccessfulRead</c> is arbitrarily stale. Staleness alone must not declare it dead.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void An_idle_healthy_driver_with_a_stale_last_read_is_left_alone()
|
||||
{
|
||||
var driver = new HealthControlledStubDriver
|
||||
{
|
||||
Health = new DriverHealth(DriverState.Healthy, DateTime.UtcNow.AddHours(-2), null),
|
||||
};
|
||||
var (_, parent) = ConnectDriver(driver);
|
||||
|
||||
AwaitCondition(
|
||||
() => driver.HealthReadCount >= 12,
|
||||
TimeSpan.FromSeconds(5),
|
||||
"health-poll ticks did not run — the absence assertion below would be vacuous");
|
||||
|
||||
parent.ExpectNoMsg(TimeSpan.FromMilliseconds(200));
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// A driver that connects but never manages a single read reports <c>LastSuccessfulRead = null</c>,
|
||||
/// so staleness has no natural baseline. The watchdog measures from the Connected entry instead —
|
||||
/// otherwise a never-read driver would be the one case that could never be declared dead.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void A_driver_that_never_reads_after_connecting_is_declared_disconnected()
|
||||
{
|
||||
var driver = new HealthControlledStubDriver
|
||||
{
|
||||
Health = new DriverHealth(DriverState.Degraded, LastSuccessfulRead: null, "never read"),
|
||||
};
|
||||
var (_, parent) = ConnectDriver(driver);
|
||||
|
||||
parent.ExpectMsg<DriverInstanceActor.ConnectivityChanged>(TimeSpan.FromSeconds(3))
|
||||
.Connected.ShouldBeFalse();
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// A <see cref="IDriver.GetHealth"/> that throws is a failed observation, not evidence that the
|
||||
/// device is gone. Treating it as a trip would let a buggy health accessor cycle a working driver.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void A_throwing_GetHealth_is_not_evidence_of_comms_loss()
|
||||
{
|
||||
var driver = new HealthControlledStubDriver { GetHealthShouldThrow = true };
|
||||
var (_, parent) = ConnectDriver(driver);
|
||||
|
||||
AwaitCondition(
|
||||
() => driver.HealthReadCount >= 12,
|
||||
TimeSpan.FromSeconds(5),
|
||||
"health-poll ticks did not run — the absence assertion below would be vacuous");
|
||||
|
||||
parent.ExpectNoMsg(TimeSpan.FromMilliseconds(200));
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// #527's second acceptance criterion, end to end: the driver recovers by itself once the device
|
||||
/// returns, with no node restart. Trip → Reconnecting → retry re-initialises → Connected, and the
|
||||
/// host is told connectivity is back.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void The_driver_recovers_on_its_own_once_the_device_returns()
|
||||
{
|
||||
var driver = new HealthControlledStubDriver
|
||||
{
|
||||
Health = new DriverHealth(DriverState.Degraded, DateTime.UtcNow.AddMinutes(-5), "socket timeout"),
|
||||
};
|
||||
var (_, parent) = ConnectDriver(driver, reconnectInterval: TimeSpan.FromMilliseconds(100));
|
||||
|
||||
parent.ExpectMsg<DriverInstanceActor.ConnectivityChanged>(TimeSpan.FromSeconds(3))
|
||||
.Connected.ShouldBeFalse();
|
||||
|
||||
// The device comes back: the next initialise attempt succeeds and reads resume.
|
||||
driver.Health = new DriverHealth(DriverState.Healthy, DateTime.UtcNow, null);
|
||||
|
||||
parent.ExpectMsg<DriverInstanceActor.ConnectivityChanged>(TimeSpan.FromSeconds(5))
|
||||
.Connected.ShouldBeTrue();
|
||||
driver.InitializeCount.ShouldBeGreaterThan(1, "the driver was never re-initialised");
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The leak guard. Several drivers overwrite an <see cref="IAsyncDisposable"/> transport field
|
||||
/// inside <c>InitializeAsync</c> without disposing the previous one (<c>ModbusDriver._transport</c>,
|
||||
/// <c>MqttDriver._connection</c>), so re-initialising without a teardown leaks one socket per
|
||||
/// attempt. Latent while only an operator's Force Reconnect re-entered this path; the watchdog
|
||||
/// makes it automatic and unbounded, so the retry must shut down first.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void A_reconnect_attempt_tears_the_dead_transport_down_before_re_initialising()
|
||||
{
|
||||
var driver = new HealthControlledStubDriver
|
||||
{
|
||||
Health = new DriverHealth(DriverState.Degraded, DateTime.UtcNow.AddMinutes(-5), "socket timeout"),
|
||||
};
|
||||
var (_, parent) = ConnectDriver(driver, reconnectInterval: TimeSpan.FromMilliseconds(100));
|
||||
|
||||
parent.ExpectMsg<DriverInstanceActor.ConnectivityChanged>(TimeSpan.FromSeconds(3))
|
||||
.Connected.ShouldBeFalse();
|
||||
|
||||
AwaitCondition(
|
||||
() => driver.InitializeCount >= 2,
|
||||
TimeSpan.FromSeconds(5),
|
||||
"the reconnect retry never re-initialised the driver");
|
||||
|
||||
// Ordering, not just counts: EVERY re-initialise must be immediately preceded by a shutdown, since
|
||||
// it is the initialise that overwrites the transport field. Asserting ShutdownCount > 0 alone would
|
||||
// also pass on a teardown that happened afterwards, which frees nothing before the overwrite.
|
||||
//
|
||||
// The sequence is deliberately not pinned to a fixed length: this driver reports stale health even
|
||||
// after a successful re-init, so the watchdog trips again and the cycle repeats — the real
|
||||
// behaviour for a device that accepts a connection but serves no data. Every additional cycle is
|
||||
// another chance for the invariant to be violated, so a longer run is a stronger test, not a
|
||||
// flakier one.
|
||||
var lifecycle = driver.Lifecycle;
|
||||
lifecycle[0].ShouldBe("init", "the first connect must not tear down a driver that was never up");
|
||||
for (var i = 1; i < lifecycle.Count; i++)
|
||||
{
|
||||
if (lifecycle[i] != "init") continue;
|
||||
lifecycle[i - 1].ShouldBe(
|
||||
"shutdown",
|
||||
$"re-initialise at index {i} was not preceded by a teardown — the previous transport leaks. " +
|
||||
$"Full sequence: [{string.Join(", ", lifecycle)}]");
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The escape hatch is real: a zero threshold disables the watchdog entirely, leaving the
|
||||
/// pre-#527 behaviour. Pinned because tests elsewhere rely on a Connected driver staying Connected
|
||||
/// while reporting non-Healthy.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void A_zero_threshold_disables_the_watchdog()
|
||||
{
|
||||
var driver = new HealthControlledStubDriver
|
||||
{
|
||||
Health = new DriverHealth(DriverState.Degraded, DateTime.UtcNow.AddMinutes(-5), "socket timeout"),
|
||||
};
|
||||
var (_, parent) = ConnectDriver(driver, commsLossTimeout: TimeSpan.Zero);
|
||||
|
||||
AwaitCondition(
|
||||
() => driver.HealthReadCount >= 12,
|
||||
TimeSpan.FromSeconds(5),
|
||||
"health-poll ticks did not run — the absence assertion below would be vacuous");
|
||||
|
||||
parent.ExpectNoMsg(TimeSpan.FromMilliseconds(200));
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// A <see cref="StubDriver"/> whose health is fully driven by the test, counting observations so an
|
||||
/// absence assertion can prove the watchdog actually ran, and recording lifecycle call ORDER so the
|
||||
/// teardown-before-reinitialise guard can assert sequence rather than mere counts.
|
||||
/// </summary>
|
||||
internal sealed class HealthControlledStubDriver : StubDriver
|
||||
{
|
||||
private readonly Lock _gate = new();
|
||||
private int _healthReadCount;
|
||||
private DateTime _firstReadUtc;
|
||||
private DateTime _lastReadUtc;
|
||||
|
||||
/// <summary>The health returned by every <see cref="GetHealth"/> call; ignored when
|
||||
/// <see cref="HealthFactory"/> is set.</summary>
|
||||
public DriverHealth Health { get; set; } = new(DriverState.Healthy, DateTime.UtcNow, null);
|
||||
|
||||
/// <summary>Per-call health, for modelling a driver whose <c>LastSuccessfulRead</c> keeps advancing.</summary>
|
||||
public Func<DriverHealth>? HealthFactory { get; set; }
|
||||
|
||||
/// <summary>When true, <see cref="GetHealth"/> throws — a failed observation.</summary>
|
||||
public bool GetHealthShouldThrow { get; set; }
|
||||
|
||||
/// <summary>Number of <see cref="GetHealth"/> calls; the positive control for absence assertions.</summary>
|
||||
public int HealthReadCount => Volatile.Read(ref _healthReadCount);
|
||||
|
||||
/// <summary>Wall-clock span between the first and last observation — proves an absence window
|
||||
/// genuinely exceeded the trip threshold rather than merely counting fast ticks.</summary>
|
||||
public TimeSpan ObservedSpan
|
||||
{
|
||||
get { lock (_gate) return _lastReadUtc - _firstReadUtc; }
|
||||
}
|
||||
|
||||
/// <summary>Ordered lifecycle log: <c>"init"</c> / <c>"shutdown"</c>, in call order.</summary>
|
||||
public IReadOnlyList<string> Lifecycle
|
||||
{
|
||||
get { lock (_gate) return _lifecycle.ToArray(); }
|
||||
}
|
||||
|
||||
private readonly List<string> _lifecycle = new();
|
||||
|
||||
/// <inheritdoc />
|
||||
public override async Task InitializeAsync(string driverConfigJson, CancellationToken cancellationToken)
|
||||
{
|
||||
lock (_gate) _lifecycle.Add("init");
|
||||
await base.InitializeAsync(driverConfigJson, cancellationToken);
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
public override Task ShutdownAsync(CancellationToken cancellationToken)
|
||||
{
|
||||
lock (_gate) _lifecycle.Add("shutdown");
|
||||
return base.ShutdownAsync(cancellationToken);
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
public override DriverHealth GetHealth()
|
||||
{
|
||||
Interlocked.Increment(ref _healthReadCount);
|
||||
lock (_gate)
|
||||
{
|
||||
var now = DateTime.UtcNow;
|
||||
if (_firstReadUtc == default) _firstReadUtc = now;
|
||||
_lastReadUtc = now;
|
||||
}
|
||||
if (GetHealthShouldThrow) throw new InvalidOperationException("stub-health-fail");
|
||||
return HealthFactory is { } factory ? factory() : Health;
|
||||
}
|
||||
}
|
||||
@@ -33,7 +33,7 @@ internal class StubDriver : IDriver
|
||||
/// <summary>Initializes the driver with the specified configuration JSON.</summary>
|
||||
/// <param name="driverConfigJson">The driver configuration JSON.</param>
|
||||
/// <param name="cancellationToken">Cancellation token for the operation.</param>
|
||||
public async Task InitializeAsync(string driverConfigJson, CancellationToken cancellationToken)
|
||||
public virtual async Task InitializeAsync(string driverConfigJson, CancellationToken cancellationToken)
|
||||
{
|
||||
Interlocked.Increment(ref InitializeCount);
|
||||
lock (_initConfigsLock) InitConfigs.Add(driverConfigJson);
|
||||
@@ -56,13 +56,20 @@ internal class StubDriver : IDriver
|
||||
|
||||
/// <summary>Shuts down the driver.</summary>
|
||||
/// <param name="cancellationToken">Cancellation token for the operation.</param>
|
||||
public Task ShutdownAsync(CancellationToken cancellationToken)
|
||||
public virtual Task ShutdownAsync(CancellationToken cancellationToken)
|
||||
{
|
||||
Interlocked.Increment(ref ShutdownCount);
|
||||
return Task.CompletedTask;
|
||||
}
|
||||
/// <summary>Gets the health status of the driver.</summary>
|
||||
public DriverHealth GetHealth() => new(DriverState.Healthy, DateTime.UtcNow, null);
|
||||
/// <remarks>
|
||||
/// Virtual so the #527 comms-loss watchdog suite can drive health directly. Note the
|
||||
/// <see cref="DateTime.UtcNow"/>: this stub is permanently Healthy with an always-fresh
|
||||
/// <c>LastSuccessfulRead</c>, so the watchdog can never fire for it — which is why every existing
|
||||
/// test built on <see cref="StubDriver"/> is unaffected by the watchdog, and equally why a watchdog
|
||||
/// test built on it would be vacuous.
|
||||
/// </remarks>
|
||||
public virtual DriverHealth GetHealth() => new(DriverState.Healthy, DateTime.UtcNow, null);
|
||||
}
|
||||
|
||||