docs: rewrite IncrementalSync + AddressSpace for v3, fix driver-specs/driver-stability tier claims, update Secrets runbook for pair replication + KEK rotation (#623)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
This commit is contained in:
@@ -96,14 +96,15 @@ to the actual offending register(s). Per-tag escape hatch:
|
||||
from the driver's `DriverConfig` JSON. Key fields:
|
||||
|
||||
- **Endpoint** — `Host`, `Port` (default 502), `UnitId`, `Timeout`. Per-tag `UnitId` overrides drive multi-slave gateway topology.
|
||||
- **`Transport`** — `Tcp` (default; MBAP header + transaction id) or `RtuOverTcp` (RTU `[addr][PDU][CRC-16]` framing tunnelled over the socket to a serial-to-Ethernet gateway); string-valued, absent = `Tcp`. The Test Connect probe follows the authored mode.
|
||||
- **`Tags`** — the pre-declared `ModbusTagDefinition` list; this *is* the address space.
|
||||
- **`Probe`** — connectivity-probe interval / timeout / probe register (default register 0).
|
||||
- **Read/write caps** — `MaxRegistersPerRead` (125), `MaxRegistersPerWrite` (123), `MaxCoilsPerRead` (2000), plus `MaxReadGap` and `AutoProhibitReprobeInterval` for coalescing.
|
||||
- **Function-code overrides** — `UseFC15ForSingleCoilWrites`, `UseFC16ForSingleRegisterWrites` for PLCs that only accept multi-write codes.
|
||||
- **Resilience** — `AutoReconnect`, `KeepAlive`, `IdleDisconnectTimeout`, `Reconnect` backoff, and `WriteOnChangeOnly` redundant-write suppression.
|
||||
|
||||
Full per-field descriptions live in `ModbusDriverOptions.cs`. The JSON skeleton
|
||||
is reproduced in [docs/v2/driver-specs.md §2](../v2/driver-specs.md).
|
||||
Full per-field descriptions live in `ModbusDriverOptions.cs`. The v2-era JSON skeleton
|
||||
in [docs/v2/driver-specs.md §2](../v2/driver-specs.md) predates the `Transport` key and the v3 raw-tag model.
|
||||
|
||||
## Testing
|
||||
|
||||
|
||||
@@ -103,7 +103,7 @@ Three properties worth knowing:
|
||||
- **Historian.Gateway** (server-side historian backend, not a tag driver) is documented in the main guide:
|
||||
- [../Historian.md](../Historian.md) — HistorianGateway backend: read-path registration, HistoryRead dispatch, alarm store-and-forward (`SendEvent`), continuous historization (`WriteLiveValues`), `EnsureTags` provisioning, config keys, deployment prerequisites. (The retired Wonderware sidecar backend it replaced: [Historian.Wonderware.md](Historian.Wonderware.md).)
|
||||
|
||||
- The full per-field spec (capability surface, config schema, addressing, data-type maps, connection settings, quirks for every driver) lives in [docs/v2/driver-specs.md](../v2/driver-specs.md). The overview pages above are the short path; that file is the authoritative per-driver reference.
|
||||
- The full per-field spec (capability surface, config schema, addressing, data-type maps, connection settings, quirks for every driver) lives in [docs/v2/driver-specs.md](../v2/driver-specs.md). The overview pages above are the short path and are the current reference; that file is the v2-era per-field spec (see its status banner for which drivers it covers).
|
||||
|
||||
## Test-fixture coverage maps
|
||||
|
||||
@@ -114,7 +114,7 @@ Each driver has a dedicated fixture doc that lays out what the integration / uni
|
||||
- [Siemens S7](S7-Test-Fixture.md) — Dockerized `python-snap7` server; DB/MB read + write round-trip verified end-to-end on `:1102`
|
||||
- [AB Legacy](AbLegacy-Test-Fixture.md) — Dockerized `ab_server` PCCC mode across SLC500 / MicroLogix / PLC-5 profiles (task #224); N/F/L-file round-trip verified end-to-end. `/1,0` cip-path required for the Docker fixture; real hardware uses empty. Residual gap: bit-file writes (`B3:0/5`) still surface BadState — real HW / RSEmulate 500 for those
|
||||
- [TwinCAT](TwinCAT-Test-Fixture.md) — XAR-VM integration scaffolding (task #221); three smoke tests skip when VM unreachable. Unit via `FakeTwinCATClient` with native-notification harness
|
||||
- [FOCAS](FOCAS-Test-Fixture.md) — no integration fixture, unit-only via `FakeFocasClient`; Tier C out-of-process isolation scoped but not shipped
|
||||
- [FOCAS](FOCAS-Test-Fixture.md) — no integration fixture, unit-only via `FakeFocasClient`; FOCAS runs in-process (Tier A) — the Tier C out-of-process isolation once scoped was never built
|
||||
- [OPC UA Client](OpcUaClient-Test-Fixture.md) — Dockerized `opc-plc` integration suite (task #215): real Secure Channel + Session, read + subscribe verified end-to-end; write not yet exercised in the integration suite; exhaustive capability matrix (reconnect, failover, cert-auth, history, alarms) via unit suite with mocked `Session`
|
||||
- [MQTT](Mqtt-Test-Fixture.md) — Dockerized `eclipse-mosquitto` with **TLS + real auth on both listeners (no anonymous fallback)** + a JSON-publisher sidecar; env-gated live suite (**15 tests**) — 7 plain (TLS/auth connect, CA pinning both ways, subscribe→value, retained seeding, wrong-password rejection) + 8 Sparkplug against a **project-owned C# edge-node simulator** on the `sparkplug` compose profile (birth→alias bind, DDATA, NDEATH→STALE, rebirth NCMD round-trip). Births are never retained, so `docker restart otopcua-sparkplug-sim` is how you force a fresh one
|
||||
- [Galaxy](../v1/drivers/Galaxy-Test-Fixture.md) — richest harness: gateway E2E + ZB SQL live-smoke + MXAccess opt-in (v1 archive)
|
||||
@@ -125,5 +125,5 @@ Each driver has a dedicated fixture doc that lays out what the integration / uni
|
||||
- [HistoricalDataAccess.md](../v1/HistoricalDataAccess.md) — `IHistoryProvider` dispatch, aggregate mapping, continuation points. The OPC UA Client driver is the only driver that implements driver-side `IHistoryProvider` (it forwards HistoryRead to the upstream server); the AVEVA Historian path is served server-side by the HistorianGateway-backed `IHistorianDataSource` instead. Other drivers do not implement the interface and return `BadHistoryOperationUnsupported`.
|
||||
- [AlarmTracking.md](../AlarmTracking.md) — `IAlarmSource` event model and filtering. Implemented by Galaxy (native MxAccess alarms, working end-to-end), OPC UA Client, AB CIP, and FOCAS; AB Legacy, Modbus, S7, TwinCAT, and MQTT have no alarm source.
|
||||
- [Subscriptions.md](../v1/Subscriptions.md) — how the Server multiplexes subscriptions onto `ISubscribable.OnDataChange`.
|
||||
- [docs/v2/driver-stability.md](../v2/driver-stability.md) — tier system (A / B / C), shared `CapabilityPolicy` defaults per tier × capability, `MemoryTracking` hybrid formula, and process-level recycle rules.
|
||||
- [docs/v2/driver-stability.md](../v2/driver-stability.md) — historical design record of the A / B / C tier model. Only `DriverTier` + the `CapabilityPolicy` defaults per tier × capability (`DriverResilienceOptions.GetTierDefaults`) are live; its `MemoryTracking` / recycle / out-of-process isolation machinery was deleted (#522) and every driver runs Tier A.
|
||||
- [docs/v2/plan.md](../v2/plan.md) — authoritative vision, architecture decisions, migration strategy.
|
||||
|
||||