@@ -57,7 +57,11 @@ operates off a **static, per-site tag list**, not live symbol discovery.
pick the family that matches the PLC exactly. `Rack` is almost always `0`
(relevant only for distributed S7-400 racks). `Slot` conventions per family:
S7-300 = slot 2, S7-400 = slot 2 or 3, S7-1200 / S7-1500 = slot 0 (onboard PN).
A wrong slot causes a connection refusal during the handshake. See
The `CpuType` JSON strings are `S7300`, `S7400`, `S71200`, `S71500` and the legacy
families `S7200` (S7-200), `S7200Smart` (S7-200 Smart) and `Logo0BA8` (LOGO! 0BA8).
For the three legacy families S7.Net uses fixed TSAPs, so `Rack` / `Slot` are not
consulted — leave them `0` / `0`; support is limited S7comm and unverified against
hardware. A wrong slot causes a connection refusal during the handshake. See
`src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.S7.Contracts/S7DriverOptions.cs` for the
per-field defaults.
+1 -1
View File
@@ -366,7 +366,7 @@ Pure managed .NET, MIT license. No native dependencies.
| `Host` | string | — | PLC IP address |
| `Rack` | int | 0 | Hardware rack number |
| `Slot` | int | 0 | CPU slot (S7-300=2, S7-1200/1500=0) |
| `CpuType` | enum | S71500 | `S7300`, `S7400`, `S71200`, `S71500` |
| `CpuType` | enum | S71500 | `S7300`, `S7400`, `S71200`, `S71500`; legacy families `S7200`, `S7200Smart`, `Logo0BA8` (S7.Net uses fixed TSAPs for these, so `Rack`/`Slot` are not consulted — leave `0`/`0`; limited S7comm support, unverified against hardware) |
| `TimeoutMs` | int | 5000 | Read/write timeout |
| `MaxConcurrentConnections` | int | 1 | Connections to this PLC (usually 1) |