Merge pull request 'Clarify S7 counter evidence and fixture limits' (#715) from docs/s7-counter-evidence into master
v2-ci / unit-tests (push) Has been cancelled
v2-ci / unit-tests (push) Has been cancelled
This commit was merged in pull request #715.
This commit is contained in:
+45
-7
@@ -198,15 +198,53 @@ Timers are **read-only** this phase; a write attempt returns `BadNotWritable`.
|
|||||||
### Counter read
|
### Counter read
|
||||||
|
|
||||||
**Address**: `C{n}` (e.g. `C0`, `C10`). **DataType must be `Int32`**. The OPC UA node is
|
**Address**: `C{n}` (e.g. `C0`, `C10`). **DataType must be `Int32`**. The OPC UA node is
|
||||||
a scalar `Int32` whose value is the current **count** (raw word from the PLC).
|
a scalar `Int32` containing the unsigned **raw big-endian word**, widened to `Int32`:
|
||||||
|
`(bytes[0] << 8) | bytes[1]`. `S7.Net`'s `Counter.FromByteArray` performs no BCD
|
||||||
|
reinterpretation; for example, bytes `01 23` surface as `291`. This describes the
|
||||||
|
current decoder, not verified agreement with a PLC's displayed count.
|
||||||
Counters are **read-only** this phase; a write attempt returns `BadNotWritable`.
|
Counters are **read-only** this phase; a write attempt returns `BadNotWritable`.
|
||||||
|
|
||||||
> **Known limitation — Counter BCD encoding on S7-300/400**: `S7.Net`'s
|
The S7comm ReadVar **C-area response encoding remains unverified on hardware**.
|
||||||
> `Counter.FromByteArray` returns the raw big-endian word without BCD decode.
|
PLC instruction representations do not by themselves establish network encoding:
|
||||||
> On **classic S7-300/400** the C-area word is BCD-encoded (0–999), so the
|
Siemens documents a binary current value for [L: Load counter](https://docs.tia.siemens.cloud/r/en-us/v21/stl-s7-300-s7-400/stl-mnemonic-s7-300-s7-400/counter-operations-s7-300-s7-400/l-load-counter-s7-300-s7-400)
|
||||||
> surfaced value can differ from the actual count on that hardware. S7-1200/1500
|
and separate `CV` and `CV_BCD` outputs for [S_CD](https://docs.tia.siemens.cloud/r/en-us/v21/lad-s7-300-s7-400/counter-operations-s7-300-s7-400/simatic-counters-s7-300-s7-400/s_cd-assign-parameters-and-count-down-s7-300-s7-400?contentId=reR_xapFX_Ike2opHIvfzg).
|
||||||
> use IEC/DB counters (plain integers) where the raw word is correct. BCD
|
|
||||||
> reinterpretation for legacy C-area is a live-hardware-gated follow-up.
|
IEC counter values stored in DB memory use the **DB address and declared integer
|
||||||
|
type**, a different read path from `C{n}`. CPU family alone does not select the
|
||||||
|
counter kind or prove its wire representation. In particular, Siemens also lists
|
||||||
|
legacy SIMATIC counters for S7-1500 in its [instruction comparison (pages 23–24)](https://cache.industry.siemens.com/dl/files/777/109986777/att_1322640/v1/s7_1500_compare_table_en.pdf?download=true).
|
||||||
|
The driver has no counter encoding selector; hardware-faithful counter support
|
||||||
|
requires independent raw-response evidence before any interpretation change.
|
||||||
|
|
||||||
|
### Counter evidence follow-up (#616)
|
||||||
|
|
||||||
|
The existing `S7_1500SpanReadTests` exercises the python-snap7 profile's synthetic
|
||||||
|
raw words (`C0 = 4711`, `C7 = 31337`). These are outside the classic SIMATIC count
|
||||||
|
range `0..999` documented by S_CD. These expectations describe raw-word handling;
|
||||||
|
they do not establish classic counter count semantics. The recorded device-0 run cannot prove nonzero
|
||||||
|
numbering. The nonzero test is environment-gated, but its options remain
|
||||||
|
`CpuType = S71500`, rack `0`, slot `0`: setting `S7_TIMER_NUMBER_ADDRESSING=1`
|
||||||
|
does not configure a classic CPU or make the profile a classic counter gate.
|
||||||
|
|
||||||
|
Before claiming hardware validation or closing #616:
|
||||||
|
|
||||||
|
- Prepare a separate target-specific semantic gate with the actual CPU type,
|
||||||
|
rack, slot and TSAP/connection settings. Keep the synthetic raw-word profile
|
||||||
|
as its own evidence of the existing decoder contract.
|
||||||
|
- Record CPU model/order number, firmware, endpoint, connection settings and
|
||||||
|
driver/S7netplus plus simulator versions where applicable.
|
||||||
|
- Observe independent PLC-side current counts and binary/BCD reference outputs
|
||||||
|
for valid classic counts such as `123`, a second distinguishing count (`42`
|
||||||
|
or `999`), and zero. Record the instruction/counter kind and DB reference
|
||||||
|
addresses; do not derive reference values from the driver's output.
|
||||||
|
- Capture the actual two-byte S7comm C-area responses alongside those references.
|
||||||
|
Do not infer response bytes from a simulator seed or expected BCD value.
|
||||||
|
- Verify several distinct nonzero timer/counter numbers against their independent
|
||||||
|
PLC values and captured requests/responses, and verify the read-only contract.
|
||||||
|
|
||||||
|
The raw-byte/count and nonzero-numbering gates remain open. Password/protection
|
||||||
|
support inherited from #303/#632 is a separate follow-up, not evidence supplied
|
||||||
|
by these counter checks.
|
||||||
|
|
||||||
### Deferrals (not yet implemented)
|
### Deferrals (not yet implemented)
|
||||||
|
|
||||||
|
|||||||
@@ -1465,7 +1465,7 @@ public sealed class S7Driver
|
|||||||
{
|
{
|
||||||
// AREA precedence first (before the DataType switch): a Timer (T{n}) decodes its 2-byte
|
// AREA precedence first (before the DataType switch): a Timer (T{n}) decodes its 2-byte
|
||||||
// S5TIME word to a duration in SECONDS via S7.Net's Timer.FromByteArray (returns double);
|
// S5TIME word to a duration in SECONDS via S7.Net's Timer.FromByteArray (returns double);
|
||||||
// a Counter (C{n}) decodes its 2-byte word to a COUNT via Counter.FromByteArray (returns
|
// a Counter (C{n}) exposes its 2-byte RAW WORD via Counter.FromByteArray (returns
|
||||||
// ushort, surfaced as a non-negative int to match the tag's Int32 type). Routing on Area
|
// ushort, surfaced as a non-negative int to match the tag's Int32 type). Routing on Area
|
||||||
// here is essential: a Timer tag is typed Float64, so letting it fall to the Float64 arm
|
// here is essential: a Timer tag is typed Float64, so letting it fall to the Float64 arm
|
||||||
// below would ReadDoubleBigEndian over a 2-byte block = garbage/throw. Boxed explicitly so
|
// below would ReadDoubleBigEndian over a 2-byte block = garbage/throw. Boxed explicitly so
|
||||||
@@ -1474,11 +1474,12 @@ public sealed class S7Driver
|
|||||||
return (object)global::S7.Net.Types.Timer.FromByteArray(block);
|
return (object)global::S7.Net.Types.Timer.FromByteArray(block);
|
||||||
if (addr.Area is S7Area.Counter)
|
if (addr.Area is S7Area.Counter)
|
||||||
{
|
{
|
||||||
// NOTE: S7.Net Counter.FromByteArray returns the RAW big-endian word ((bytes[0]<<8)|bytes[1]),
|
// S7.Net Counter.FromByteArray returns the raw big-endian word ((bytes[0]<<8)|bytes[1]),
|
||||||
// NOT a BCD decode. On classic S7-300/400 the C-area word is BCD (0-999), so on that hardware
|
// without BCD reinterpretation. This preserves the raw value, not a verified PLC count:
|
||||||
// this raw value can differ from the displayed count; S7-1200/1500 use IEC/DB counters (plain
|
// S7comm C-area response encoding still needs independent raw bytes and PLC-side
|
||||||
// ints), where it is correct. Surfacing S7.Net's value verbatim is the faithful choice; BCD
|
// count/binary/BCD references (#616). CPU family alone does not prove that encoding.
|
||||||
// reinterpretation for legacy C-area counters is a live-hardware-gated follow-up.
|
// IEC counter integers in DB memory take the DB type codec, not this C-area path;
|
||||||
|
// S7-1500 also has legacy SIMATIC counters. See docs/drivers/S7.md for the evidence gate.
|
||||||
return (object)(int)global::S7.Net.Types.Counter.FromByteArray(block);
|
return (object)(int)global::S7.Net.Types.Counter.FromByteArray(block);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||
+26
-12
@@ -27,7 +27,15 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests.S7_1500;
|
|||||||
/// areas: <b>PASSED</b> — 4 passed, 0 failed, 1 skipped (the device number-addressing test,
|
/// areas: <b>PASSED</b> — 4 passed, 0 failed, 1 skipped (the device number-addressing test,
|
||||||
/// see below). The Timer/Counter batch was served by 4 requests for 7 tags: one DB1 span,
|
/// see below). The Timer/Counter batch was served by 4 requests for 7 tags: one DB1 span,
|
||||||
/// one 3-item multi-var carrying only the scalars, and one 2-byte area read apiece for
|
/// one 3-item multi-var carrying only the scalars, and one 2-byte area read apiece for
|
||||||
/// <c>T0</c> (decoded 456.0 s from S5TIME <c>0x2456</c>) and <c>C0</c> (decoded count 4711).
|
/// <c>T0</c> (decoded 456.0 s from S5TIME <c>0x2456</c>) and <c>C0</c> (surfaced raw word 4711).
|
||||||
|
/// </para>
|
||||||
|
/// <para>
|
||||||
|
/// <b>Counter evidence limit.</b> The profile's C0=4711 and C7=31337 are synthetic raw
|
||||||
|
/// words, outside classic SIMATIC counts 0..999. The device-0 record proves the fixture's
|
||||||
|
/// raw-word decode and batching exclusion, not classic count semantics or nonzero
|
||||||
|
/// addressing. BuildOptions retains S71500/rack 0/slot 0; a target-specific semantic gate
|
||||||
|
/// still needs independent PLC counts and binary/BCD references paired with captured
|
||||||
|
/// C-area bytes, CPU model/firmware and connection settings (docs/drivers/S7.md, #616).
|
||||||
/// </para>
|
/// </para>
|
||||||
/// <para>
|
/// <para>
|
||||||
/// <b>What the layout buys.</b> The ten tags are positioned so the planner's rules produce a
|
/// <b>What the layout buys.</b> The ten tags are positioned so the planner's rules produce a
|
||||||
@@ -73,11 +81,12 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests.S7_1500;
|
|||||||
/// returns TM bytes 0..1, and it takes <c>start 80</c> (= 10 × 8) to reach the timer seeded
|
/// returns TM bytes 0..1, and it takes <c>start 80</c> (= 10 × 8) to reach the timer seeded
|
||||||
/// at TM byte 10. Device <b>0</b> is the single fixed point of the two conventions
|
/// at TM byte 10. Device <b>0</b> is the single fixed point of the two conventions
|
||||||
/// (<c>0 >> 3 == 2 × 0 == 0</c>), so it is the only device this fixture can pin a
|
/// (<c>0 >> 3 == 2 × 0 == 0</c>), so it is the only device this fixture can pin a
|
||||||
/// VALUE for, and that is what the mixed batch uses. The spec-correct <c>2 × N</c> cells
|
/// VALUE for, and that is what the mixed batch uses. The profile's <c>2 × N</c> cells
|
||||||
/// are seeded too and
|
/// are seeded too and
|
||||||
/// <see cref="Timer_and_counter_decode_the_seeded_values_at_their_device_numbers"/> asserts
|
/// <see cref="Timer_and_counter_decode_the_seeded_values_at_their_device_numbers"/> asserts
|
||||||
/// them — skipped unless <c>S7_TIMER_NUMBER_ADDRESSING=1</c> declares the endpoint a real
|
/// them — skipped unless <c>S7_TIMER_NUMBER_ADDRESSING=1</c> declares the endpoint a real
|
||||||
/// CPU. The device-number offset arithmetic itself stays unit-covered
|
/// CPU. This flag is an operator declaration, not hardware evidence.
|
||||||
|
/// The device-number offset arithmetic itself stays unit-covered
|
||||||
/// (<c>S7ScalarBlockTests</c>, <c>S7SpanReadParityTests</c>).
|
/// (<c>S7ScalarBlockTests</c>, <c>S7SpanReadParityTests</c>).
|
||||||
/// </para>
|
/// </para>
|
||||||
/// <para>
|
/// <para>
|
||||||
@@ -240,7 +249,7 @@ public sealed class S7_1500SpanReadTests(Snap7ServerFixture sim)
|
|||||||
snapshot.StatusCode.ShouldBe(0u, $"'{name}' must be Good");
|
snapshot.StatusCode.ShouldBe(0u, $"'{name}' must be Good");
|
||||||
|
|
||||||
// (a) Correct decode off real wire. A Timer surfaces as the S5TIME word's duration in
|
// (a) Correct decode off real wire. A Timer surfaces as the S5TIME word's duration in
|
||||||
// seconds (double) and a Counter as the raw count (int) — two different areas, two
|
// seconds (double) and a Counter as the raw word (int) — two different areas, two
|
||||||
// different values, two different CLR types, so a read that reached the wrong area or
|
// different values, two different CLR types, so a read that reached the wrong area or
|
||||||
// decoded through the wrong arm cannot pass.
|
// decoded through the wrong arm cannot pass.
|
||||||
byName["TC_Timer"].Value.ShouldBe(TimerCounterLayout.Device0TimerSeconds);
|
byName["TC_Timer"].Value.ShouldBe(TimerCounterLayout.Device0TimerSeconds);
|
||||||
@@ -280,15 +289,19 @@ public sealed class S7_1500SpanReadTests(Snap7ServerFixture sim)
|
|||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
/// Verifies a Timer and a Counter at NON-zero device numbers decode their seeded values —
|
/// Verifies a Timer and a Counter at NON-zero device numbers decode their seeded values —
|
||||||
/// the assertion the shared fixture cannot serve.
|
/// the raw-word assertion the shared fixture cannot serve.
|
||||||
/// </summary>
|
/// </summary>
|
||||||
/// <remarks>
|
/// <remarks>
|
||||||
/// Skipped unless <c>S7_TIMER_NUMBER_ADDRESSING=1</c> declares the endpoint a device
|
/// Skipped unless <c>S7_TIMER_NUMBER_ADDRESSING=1</c> declares the endpoint a device
|
||||||
/// number-addressing CPU, because python-snap7's server is not one: it resolves the TM/CT
|
/// number-addressing CPU, because python-snap7's server is not one: it resolves the TM/CT
|
||||||
/// request address as a bit address, so <c>T5</c> reads TM byte 0 rather than TM byte 10
|
/// request address as a bit address, so <c>T5</c> reads TM byte 0 rather than TM byte 10
|
||||||
/// (measured 2026-08-17 — see the type remarks). Set the variable alongside
|
/// (measured 2026-08-17 — see the type remarks). The flag only enables this test;
|
||||||
/// <c>S7_SIM_ENDPOINT</c> when pointing this suite at a real S7 CPU seeded to match
|
/// BuildOptions still selects S71500, rack 0, slot 0 and the profile's raw C7 word 31337.
|
||||||
/// <c>Docker/profiles/s7_1500.json</c>'s TM/CT areas.
|
/// It does not configure a classic CPU or prove classic 0..999 count semantics. A separate
|
||||||
|
/// target-specific gate needs valid counts, independent PLC binary/BCD references and
|
||||||
|
/// captured C-area bytes, plus CPU model/firmware and connection settings (#616).
|
||||||
|
/// See docs/drivers/S7.md for the evidence checklist. The skip message below retains the
|
||||||
|
/// historical fixture instructions; enabling the flag alone does not satisfy this gate.
|
||||||
/// </remarks>
|
/// </remarks>
|
||||||
[Fact]
|
[Fact]
|
||||||
public async Task Timer_and_counter_decode_the_seeded_values_at_their_device_numbers()
|
public async Task Timer_and_counter_decode_the_seeded_values_at_their_device_numbers()
|
||||||
@@ -408,12 +421,13 @@ public sealed class S7_1500SpanReadTests(Snap7ServerFixture sim)
|
|||||||
/// <summary>
|
/// <summary>
|
||||||
/// The Timer/Counter layouts. Two sets: a mixed batch that provokes all three read shapes at
|
/// The Timer/Counter layouts. Two sets: a mixed batch that provokes all three read shapes at
|
||||||
/// once (block span, multi-var, per-tag Timer/Counter), and a device-numbered pair only a
|
/// once (block span, multi-var, per-tag Timer/Counter), and a device-numbered pair only a
|
||||||
/// real CPU can serve. Addresses map 1:1 to the TM0 / CT0 seeds in
|
/// device number-addressing endpoint can serve. These synthetic raw-word expectations
|
||||||
|
/// do not prove classic counter semantics. Addresses map 1:1 to the TM0 / CT0 seeds in
|
||||||
/// <c>Docker/profiles/s7_1500.json</c>.
|
/// <c>Docker/profiles/s7_1500.json</c>.
|
||||||
/// </summary>
|
/// </summary>
|
||||||
private static class TimerCounterLayout
|
private static class TimerCounterLayout
|
||||||
{
|
{
|
||||||
/// <summary>Declares the endpoint a real S7 CPU, which addresses TM/CT by device number.</summary>
|
/// <summary>Operator opt-in for nonzero TM/CT addressing; does not change CPU options or prove encoding.</summary>
|
||||||
public const string RealCpuEnvVar = "S7_TIMER_NUMBER_ADDRESSING";
|
public const string RealCpuEnvVar = "S7_TIMER_NUMBER_ADDRESSING";
|
||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
@@ -425,7 +439,7 @@ public sealed class S7_1500SpanReadTests(Snap7ServerFixture sim)
|
|||||||
/// <summary>T0's seed 0x2456 — S5TIME base 2 (×1 s) over BCD 456.</summary>
|
/// <summary>T0's seed 0x2456 — S5TIME base 2 (×1 s) over BCD 456.</summary>
|
||||||
public const double Device0TimerSeconds = 456.0d;
|
public const double Device0TimerSeconds = 456.0d;
|
||||||
|
|
||||||
/// <summary>C0's seed — the raw big-endian count word.</summary>
|
/// <summary>C0's synthetic raw big-endian word 4711; not a classic 0..999 count reference.</summary>
|
||||||
public const int Device0CounterCount = 4711;
|
public const int Device0CounterCount = 4711;
|
||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
@@ -441,7 +455,7 @@ public sealed class S7_1500SpanReadTests(Snap7ServerFixture sim)
|
|||||||
new("TC_Lone_I16", "DB1.DBW600", S7DataType.Int16),
|
new("TC_Lone_I16", "DB1.DBW600", S7DataType.Int16),
|
||||||
new("TC_Lone_Mk", "MW10", S7DataType.UInt16),
|
new("TC_Lone_Mk", "MW10", S7DataType.UInt16),
|
||||||
// Timer tags are typed Float64 (decoded to seconds) and Counter tags Int32 (decoded to
|
// Timer tags are typed Float64 (decoded to seconds) and Counter tags Int32 (decoded to
|
||||||
// a count) — the init guard rejects any other typing. Writable:false is mandatory, not
|
// a raw word) — the init guard rejects any other typing. Writable:false is mandatory, not
|
||||||
// stylistic: S7TagDefinition defaults Writable to TRUE and the same guard rejects a
|
// stylistic: S7TagDefinition defaults Writable to TRUE and the same guard rejects a
|
||||||
// writable Timer/Counter outright (they are read-only this phase).
|
// writable Timer/Counter outright (they are read-only this phase).
|
||||||
new("TC_Timer", "T0", S7DataType.Float64, Writable: false),
|
new("TC_Timer", "T0", S7DataType.Float64, Writable: false),
|
||||||
|
|||||||
Reference in New Issue
Block a user