fix(modbus): transport self-heals with one throttled in-gate connect; PDU length check
P3: a torn-down socket is re-dialled inside the gate (one attempt per backoff window) instead of failing fast with 'Transport not connected' until the 90 s comms-loss watchdog re-initialised the driver. L3: ConnectAsync disposes the previous/failed TcpClient, DNS runs under the per-op timeout, and the reconnect never sleeps inside the gate (the old 10-attempt backoff held it for ~81 s). H9: an MBAP response with no PDU, or an exception PDU with no code, is a TruncatedFrame desync rather than an IndexOutOfRangeException. Refs #741 Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
This commit is contained in:
@@ -91,7 +91,7 @@ public sealed class ModbusRtuOverTcpTransport : IModbusTransport
|
||||
public async Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
|
||||
{
|
||||
if (_disposed) throw new ObjectDisposedException(nameof(ModbusRtuOverTcpTransport));
|
||||
if (CurrentStream is null) throw new InvalidOperationException("Transport not connected");
|
||||
if (_life is null && _testStream is null) throw new InvalidOperationException("Transport not connected");
|
||||
|
||||
// Single-flight: RTU carries no transaction id, so at most one transaction may be on the bus
|
||||
// at a time — serialise every send/receive under the gate.
|
||||
@@ -101,11 +101,14 @@ public sealed class ModbusRtuOverTcpTransport : IModbusTransport
|
||||
// Proactive idle-disconnect (real socket only): if the socket has been quiet longer than
|
||||
// the configured threshold, tear it down + reconnect before this PDU lands. Defends
|
||||
// against silent NAT / firewall reaping.
|
||||
if (_life is not null && _life.ShouldReconnectForIdle())
|
||||
{
|
||||
if (_life is not null && _life.Stream is not null && _life.ShouldReconnectForIdle())
|
||||
await _life.TearDownAsync().ConfigureAwait(false);
|
||||
await _life.ConnectWithBackoffAsync(ct).ConfigureAwait(false);
|
||||
}
|
||||
|
||||
// Self-heal (real socket only): a socket torn down by an earlier failure is re-dialled here,
|
||||
// once, throttled by the backoff window — same contract as ModbusTcpTransport.
|
||||
var freshlyConnected = _life is not null && _life.Stream is null;
|
||||
if (freshlyConnected)
|
||||
await _life!.EnsureConnectedAsync(ct).ConfigureAwait(false);
|
||||
|
||||
try
|
||||
{
|
||||
@@ -113,14 +116,16 @@ public sealed class ModbusRtuOverTcpTransport : IModbusTransport
|
||||
_life?.MarkSuccess();
|
||||
return result;
|
||||
}
|
||||
catch (Exception ex) when (_life is not null && _life.AutoReconnect && ModbusSocketLifecycle.IsSocketLevelFailure(ex))
|
||||
catch (Exception ex) when (!freshlyConnected && _life is not null && _life.AutoReconnect
|
||||
&& !ct.IsCancellationRequested
|
||||
&& ModbusSocketLifecycle.IsSocketLevelFailure(ex))
|
||||
{
|
||||
// Mid-transaction drop: tear down the dead socket, reconnect (with backoff if
|
||||
// configured), resend. Single retry — a second failure propagates so health/status
|
||||
// reflect reality. Never reached in the ForTest seam (a raw injected stream has no
|
||||
// lifecycle to reconnect).
|
||||
// Mid-transaction drop: tear down the dead socket, make ONE throttled reconnect attempt
|
||||
// (never a sleep inside the gate), resend. Single retry — a second failure propagates so
|
||||
// health/status reflect reality. Never reached in the ForTest seam (a raw injected stream
|
||||
// has no lifecycle to reconnect).
|
||||
await _life.TearDownAsync().ConfigureAwait(false);
|
||||
await _life.ConnectWithBackoffAsync(ct).ConfigureAwait(false);
|
||||
await _life.EnsureConnectedAsync(ct).ConfigureAwait(false);
|
||||
var result = await SendOnceAsync(unitId, pdu, ct).ConfigureAwait(false);
|
||||
_life.MarkSuccess();
|
||||
return result;
|
||||
|
||||
@@ -4,8 +4,8 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
|
||||
|
||||
/// <summary>
|
||||
/// Owns the raw TCP socket lifecycle shared by every Modbus-over-TCP transport (MBAP and
|
||||
/// RTU-over-TCP alike): the IPv4-preference connect, OS-level keep-alive, geometric-backoff
|
||||
/// reconnect, idle-disconnect tracking, and teardown. It exposes the current
|
||||
/// RTU-over-TCP alike): the IPv4-preference connect, OS-level keep-alive, throttled
|
||||
/// reconnect (one attempt per geometric-backoff window), idle-disconnect tracking, and teardown. It exposes the current
|
||||
/// <see cref="NetworkStream"/> so the composing transport can drive its own framing on top —
|
||||
/// the lifecycle knows nothing about MBAP / RTU wire layout.
|
||||
/// </summary>
|
||||
@@ -14,7 +14,7 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
|
||||
/// Extracted verbatim from <see cref="ModbusTcpTransport"/> so the connect / reconnect /
|
||||
/// keep-alive / idle behaviour is written once and composed by both transports. The
|
||||
/// constructor is connection-free — all socket I/O happens in <see cref="ConnectAsync"/> /
|
||||
/// <see cref="ConnectWithBackoffAsync"/>.
|
||||
/// <see cref="EnsureConnectedAsync"/> (one throttled attempt per call — never a sleep loop).
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// Why keep-alive matters for DL205/DL260: the AutomationDirect H2-ECOM100 does NOT send
|
||||
@@ -37,6 +37,9 @@ public sealed class ModbusSocketLifecycle : IAsyncDisposable
|
||||
private NetworkStream? _stream;
|
||||
private DateTime _lastSuccessUtc = DateTime.UtcNow;
|
||||
|
||||
/// <summary>Monotonic millisecond clock for the reconnect throttle (test seam).</summary>
|
||||
internal Func<long> NowMs { get; set; } = () => Environment.TickCount64;
|
||||
|
||||
/// <summary>Initializes a new instance of the <see cref="ModbusSocketLifecycle"/> class.</summary>
|
||||
/// <param name="host">The host address or hostname of the Modbus server.</param>
|
||||
/// <param name="port">The TCP port of the Modbus server.</param>
|
||||
@@ -71,63 +74,107 @@ public sealed class ModbusSocketLifecycle : IAsyncDisposable
|
||||
/// <returns>A task representing the asynchronous connection operation.</returns>
|
||||
public async Task ConnectAsync(CancellationToken ct)
|
||||
{
|
||||
// Resolve the host explicitly + prefer IPv4. .NET's TcpClient default-constructor is
|
||||
// dual-stack (IPv6 first, fallback to IPv4) — but most Modbus TCP devices (PLCs and
|
||||
// simulators like pymodbus) bind 0.0.0.0 only, so the IPv6 attempt times out and we
|
||||
// burn the entire ConnectAsync budget before even trying IPv4. Resolving first +
|
||||
// dialing the IPv4 address directly sidesteps that.
|
||||
var addresses = await System.Net.Dns.GetHostAddressesAsync(_host, ct).ConfigureAwait(false);
|
||||
var ipv4 = System.Linq.Enumerable.FirstOrDefault(addresses,
|
||||
a => a.AddressFamily == System.Net.Sockets.AddressFamily.InterNetwork);
|
||||
var target = ipv4 ?? (addresses.Length > 0 ? addresses[0] : System.Net.IPAddress.Loopback);
|
||||
|
||||
_client = new TcpClient(target.AddressFamily);
|
||||
EnableKeepAlive(_client, _keepAlive);
|
||||
// A previous socket (failed, torn down or idle-reaped) is released FIRST: overwriting _client
|
||||
// used to strand the old TcpClient for the finalizer — up to nine per backoff loop.
|
||||
await TearDownAsync().ConfigureAwait(false);
|
||||
|
||||
// DNS resolution runs under the same per-op deadline as the TCP connect: an unresolvable or
|
||||
// slow resolver must not hold the transport gate for the OS resolver's own (much longer) timeout.
|
||||
using var cts = CancellationTokenSource.CreateLinkedTokenSource(ct);
|
||||
cts.CancelAfter(_timeout);
|
||||
await _client.ConnectAsync(target, _port, cts.Token).ConfigureAwait(false);
|
||||
_stream = _client.GetStream();
|
||||
_lastSuccessUtc = DateTime.UtcNow;
|
||||
TcpClient? client = null;
|
||||
try
|
||||
{
|
||||
// Resolve the host explicitly + prefer IPv4. .NET's TcpClient default-constructor is
|
||||
// dual-stack (IPv6 first, fallback to IPv4) — but most Modbus TCP devices (PLCs and
|
||||
// simulators like pymodbus) bind 0.0.0.0 only, so the IPv6 attempt times out and we
|
||||
// burn the entire ConnectAsync budget before even trying IPv4. Resolving first +
|
||||
// dialing the IPv4 address directly sidesteps that.
|
||||
var addresses = await System.Net.Dns.GetHostAddressesAsync(_host, cts.Token).ConfigureAwait(false);
|
||||
var ipv4 = System.Linq.Enumerable.FirstOrDefault(addresses,
|
||||
a => a.AddressFamily == System.Net.Sockets.AddressFamily.InterNetwork);
|
||||
var target = ipv4 ?? (addresses.Length > 0 ? addresses[0] : System.Net.IPAddress.Loopback);
|
||||
|
||||
client = new TcpClient(target.AddressFamily);
|
||||
EnableKeepAlive(client, _keepAlive);
|
||||
await client.ConnectAsync(target, _port, cts.Token).ConfigureAwait(false);
|
||||
_stream = client.GetStream();
|
||||
_client = client;
|
||||
client = null; // ownership transferred
|
||||
_lastSuccessUtc = DateTime.UtcNow;
|
||||
}
|
||||
catch (OperationCanceledException) when (!ct.IsCancellationRequested)
|
||||
{
|
||||
// The per-op deadline, not the caller: normalise to a socket-level failure so every
|
||||
// classifier treats a connect timeout as a comms fault.
|
||||
throw new ModbusTransportUnavailableException(
|
||||
$"Modbus connect to {_host}:{_port} timed out after {_timeout.TotalMilliseconds:0}ms");
|
||||
}
|
||||
finally
|
||||
{
|
||||
// A failed attempt disposes its own client — never leave it for the finalizer.
|
||||
client?.Dispose();
|
||||
}
|
||||
}
|
||||
|
||||
// Reconnect throttle state. Guarded by the composing transport's single-flight gate (every caller of
|
||||
// EnsureConnectedAsync holds it), so no extra lock is needed.
|
||||
private long _connectNotBeforeMs;
|
||||
private TimeSpan _failureDelay = TimeSpan.Zero;
|
||||
|
||||
/// <summary>
|
||||
/// Connect attempt with the configured geometric backoff. The first attempt fires after
|
||||
/// <see cref="ModbusReconnectOptions.InitialDelay"/> (default zero — immediate); each
|
||||
/// subsequent attempt sleeps for the previous delay times <c>BackoffMultiplier</c>,
|
||||
/// capped at <c>MaxDelay</c>. Caller's cancellation token aborts the loop.
|
||||
/// Ensures a live socket for the next transaction with AT MOST ONE connect attempt, throttled by the
|
||||
/// configured geometric backoff: after a failed attempt, calls inside the backoff window fail fast
|
||||
/// with <see cref="ModbusTransportUnavailableException"/> and never dial. The window starts at
|
||||
/// <see cref="ModbusReconnectOptions.InitialDelay"/> (floored at 1 s) and grows by
|
||||
/// <c>BackoffMultiplier</c> per consecutive failure up to <c>MaxDelay</c>; a successful connect
|
||||
/// resets it. Never sleeps — the composing transport calls it inside its gate, and a sleep there
|
||||
/// used to queue every read, write and probe behind one dead socket for up to ~81 s.
|
||||
/// </summary>
|
||||
/// <param name="ct">A cancellation token to observe for cancellation.</param>
|
||||
/// <returns>A task representing the asynchronous reconnect operation.</returns>
|
||||
public async Task ConnectWithBackoffAsync(CancellationToken ct)
|
||||
/// <returns>A task that completes when a socket is live.</returns>
|
||||
/// <exception cref="ModbusTransportUnavailableException">Auto-reconnect is off, or the call is inside the backoff window.</exception>
|
||||
public async Task EnsureConnectedAsync(CancellationToken ct)
|
||||
{
|
||||
var delay = _reconnect.InitialDelay;
|
||||
var attempt = 0;
|
||||
while (true)
|
||||
if (_stream is not null) return;
|
||||
if (!_autoReconnect)
|
||||
throw new ModbusTransportUnavailableException(
|
||||
$"Modbus transport to {_host}:{_port} is not connected and auto-reconnect is disabled");
|
||||
|
||||
var now = NowMs();
|
||||
if (now < _connectNotBeforeMs)
|
||||
throw new ModbusTransportUnavailableException(
|
||||
$"Modbus reconnect to {_host}:{_port} throttled for another {_connectNotBeforeMs - now}ms after a failed connect");
|
||||
|
||||
try
|
||||
{
|
||||
if (delay > TimeSpan.Zero)
|
||||
await Task.Delay(delay, ct).ConfigureAwait(false);
|
||||
try
|
||||
{
|
||||
await ConnectAsync(ct).ConfigureAwait(false);
|
||||
return;
|
||||
}
|
||||
catch (Exception ex) when (IsSocketLevelFailure(ex) && _autoReconnect)
|
||||
{
|
||||
attempt++;
|
||||
// Geometric growth, capped. Use Math.Min on ticks so we don't overflow with
|
||||
// pathological multipliers / long deployments.
|
||||
var nextTicks = (long)(Math.Max(delay.Ticks, TimeSpan.FromMilliseconds(100).Ticks) * _reconnect.BackoffMultiplier);
|
||||
delay = TimeSpan.FromTicks(Math.Min(nextTicks, _reconnect.MaxDelay.Ticks));
|
||||
if (attempt >= 10)
|
||||
{
|
||||
// Bail after 10 attempts to surface persistent failure to the caller. With
|
||||
// the default backoff (1s base, 2.0x mult, 30s cap) this is roughly 4 minutes
|
||||
// of attempts; with InitialDelay=0 it's immediate up to the same cap.
|
||||
throw;
|
||||
}
|
||||
}
|
||||
await ConnectAsync(ct).ConfigureAwait(false);
|
||||
_failureDelay = TimeSpan.Zero;
|
||||
_connectNotBeforeMs = 0;
|
||||
}
|
||||
catch (Exception) when (!ct.IsCancellationRequested)
|
||||
{
|
||||
_failureDelay = NextDelay(_failureDelay);
|
||||
_connectNotBeforeMs = NowMs() + (long)_failureDelay.TotalMilliseconds;
|
||||
throw;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Minimum reconnect window after a failed connect — a dead device is dialled at most once per second.</summary>
|
||||
private static readonly TimeSpan MinReconnectWindow = TimeSpan.FromSeconds(1);
|
||||
|
||||
private TimeSpan NextDelay(TimeSpan previous)
|
||||
{
|
||||
if (previous <= TimeSpan.Zero)
|
||||
{
|
||||
var first = _reconnect.InitialDelay > MinReconnectWindow ? _reconnect.InitialDelay : MinReconnectWindow;
|
||||
return first < _reconnect.MaxDelay ? first : _reconnect.MaxDelay > TimeSpan.Zero ? _reconnect.MaxDelay : first;
|
||||
}
|
||||
// Geometric growth, capped. Math.Min on ticks so a pathological multiplier cannot overflow.
|
||||
var multiplier = _reconnect.BackoffMultiplier >= 1.0 ? _reconnect.BackoffMultiplier : 1.0;
|
||||
var nextTicks = previous.Ticks * multiplier;
|
||||
var cap = _reconnect.MaxDelay > TimeSpan.Zero ? _reconnect.MaxDelay.Ticks : long.MaxValue;
|
||||
return TimeSpan.FromTicks(nextTicks >= cap ? cap : (long)nextTicks);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
|
||||
@@ -56,6 +56,9 @@ public sealed class ModbusTcpTransport : IModbusTransport
|
||||
_life = new ModbusSocketLifecycle(host, port, timeout, autoReconnect, keepAlive, idleDisconnect, reconnect);
|
||||
}
|
||||
|
||||
/// <summary>The socket lifecycle this transport composes (test seam for its clock).</summary>
|
||||
internal ModbusSocketLifecycle Lifecycle => _life;
|
||||
|
||||
/// <inheritdoc />
|
||||
public Task ConnectAsync(CancellationToken ct) => _life.ConnectAsync(ct);
|
||||
|
||||
@@ -63,7 +66,6 @@ public sealed class ModbusTcpTransport : IModbusTransport
|
||||
public async Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
|
||||
{
|
||||
if (_disposed) throw new ObjectDisposedException(nameof(ModbusTcpTransport));
|
||||
if (_life.Stream is null) throw new InvalidOperationException("Transport not connected");
|
||||
|
||||
await _gate.WaitAsync(ct).ConfigureAwait(false);
|
||||
try
|
||||
@@ -72,11 +74,16 @@ public sealed class ModbusTcpTransport : IModbusTransport
|
||||
// threshold, tear it down + reconnect before this PDU lands. Defends against silent
|
||||
// NAT / firewall reaping where the socket looks alive locally but the upstream side
|
||||
// dropped it minutes ago.
|
||||
if (_life.ShouldReconnectForIdle())
|
||||
{
|
||||
if (_life.Stream is not null && _life.ShouldReconnectForIdle())
|
||||
await _life.TearDownAsync().ConfigureAwait(false);
|
||||
await _life.ConnectWithBackoffAsync(ct).ConfigureAwait(false);
|
||||
}
|
||||
|
||||
// Self-heal: a socket torn down by an earlier failure (two lost replies in a row, a refused
|
||||
// reconnect) is re-dialled HERE, once, throttled by the backoff window. This used to throw
|
||||
// "Transport not connected" before the gate, so the transport never recovered on its own and
|
||||
// every call failed fast until the 90 s comms-loss watchdog re-initialised the whole driver.
|
||||
var freshlyConnected = _life.Stream is null;
|
||||
if (freshlyConnected)
|
||||
await _life.EnsureConnectedAsync(ct).ConfigureAwait(false);
|
||||
|
||||
try
|
||||
{
|
||||
@@ -84,13 +91,16 @@ public sealed class ModbusTcpTransport : IModbusTransport
|
||||
_life.MarkSuccess();
|
||||
return result;
|
||||
}
|
||||
catch (Exception ex) when (_life.AutoReconnect && ModbusSocketLifecycle.IsSocketLevelFailure(ex))
|
||||
catch (Exception ex) when (!freshlyConnected && _life.AutoReconnect
|
||||
&& !ct.IsCancellationRequested
|
||||
&& ModbusSocketLifecycle.IsSocketLevelFailure(ex))
|
||||
{
|
||||
// Mid-transaction drop: tear down the dead socket, reconnect (with backoff if
|
||||
// configured), resend. Single retry — if it fails again, let it propagate so
|
||||
// health/status reflect reality.
|
||||
// Mid-transaction drop on a socket that had been live: tear down the dead socket, make ONE
|
||||
// throttled reconnect attempt (never a sleep inside the gate), resend. Single retry — if it
|
||||
// fails again, let it propagate so health/status reflect reality. A socket this call just
|
||||
// dialled is not retried: it proved nothing about a stale connection.
|
||||
await _life.TearDownAsync().ConfigureAwait(false);
|
||||
await _life.ConnectWithBackoffAsync(ct).ConfigureAwait(false);
|
||||
await _life.EnsureConnectedAsync(ct).ConfigureAwait(false);
|
||||
var result = await SendOnceAsync(unitId, pdu, ct).ConfigureAwait(false);
|
||||
_life.MarkSuccess();
|
||||
return result;
|
||||
@@ -162,10 +172,22 @@ public sealed class ModbusTcpTransport : IModbusTransport
|
||||
var respPdu = new byte[respLen - 1];
|
||||
await ReadExactlyAsync(stream, respPdu, cts.Token).ConfigureAwait(false);
|
||||
|
||||
// Length check before indexing: a PDU must carry at least its function code, and an exception
|
||||
// PDU its exception code too. Indexing past the end used to throw IndexOutOfRangeException —
|
||||
// not an IOException, so no teardown/retry, and a malformed reply read as a driver bug.
|
||||
if (respPdu.Length < 1)
|
||||
throw new ModbusTransportDesyncException(
|
||||
ModbusTransportDesyncException.DesyncReason.TruncatedFrame,
|
||||
"Modbus response carried no PDU (MBAP length 1)");
|
||||
|
||||
// Exception PDU: function code has high bit set. This is a well-formed protocol-level
|
||||
// error — the socket is still coherent, so it MUST propagate without teardown.
|
||||
if ((respPdu[0] & 0x80) != 0)
|
||||
{
|
||||
if (respPdu.Length < 2)
|
||||
throw new ModbusTransportDesyncException(
|
||||
ModbusTransportDesyncException.DesyncReason.TruncatedFrame,
|
||||
$"Modbus exception response fc=0x{respPdu[0]:X2} carried no exception code");
|
||||
var fc = (byte)(respPdu[0] & 0x7F);
|
||||
var ex = respPdu[1];
|
||||
throw new ModbusException(fc, ex, $"Modbus exception fc={fc} code={ex}");
|
||||
|
||||
@@ -0,0 +1,23 @@
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
|
||||
|
||||
/// <summary>
|
||||
/// Raised when a Modbus transport has no live socket and cannot get one for this call: the one
|
||||
/// in-gate connect attempt failed, the reconnect is inside its backoff window, or auto-reconnect is
|
||||
/// disabled. It says the ENDPOINT is unreachable, so the driver fails the rest of the batch fast
|
||||
/// instead of paying the same failure once per tag.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// Derives from <see cref="IOException"/> so every existing socket-level classifier
|
||||
/// (<c>ModbusSocketLifecycle.IsSocketLevelFailure</c>, the driver's comms-fault mapping) treats it as
|
||||
/// a communication failure without extra plumbing.
|
||||
/// </remarks>
|
||||
public sealed class ModbusTransportUnavailableException : IOException
|
||||
{
|
||||
/// <summary>Initializes a new instance of the <see cref="ModbusTransportUnavailableException"/> class.</summary>
|
||||
/// <param name="message">A human-readable description.</param>
|
||||
/// <param name="inner">The originating exception, if any.</param>
|
||||
public ModbusTransportUnavailableException(string message, Exception? inner = null)
|
||||
: base(message, inner)
|
||||
{
|
||||
}
|
||||
}
|
||||
Reference in New Issue