test(fixtures): migrate integration-test fixture defaults to 10.100.0.35
CLAUDE.md "Docker Workflow" claims (per the 2026-04-28 migration note)
that all fixture-class default endpoints were rewritten to target the
shared Docker host at 10.100.0.35. Audit during today's e2e run showed
the claim was incomplete — five fixture classes still defaulted to
localhost / 127.0.0.1, causing every fixture-touching integration test
to skip with "endpoint unreachable" on a fresh box that hadn't set
the override env vars.
Files corrected:
- tests/.../Modbus.IntegrationTests/ModbusSimulatorFixture.cs
DefaultEndpoint: localhost:5020 → 10.100.0.35:5020
- tests/.../S7.IntegrationTests/Snap7ServerFixture.cs
DefaultEndpoint: localhost:1102 → 10.100.0.35:1102
- tests/.../OpcUaClient.IntegrationTests/OpcPlcFixture.cs
DefaultEndpoint: opc.tcp://localhost:50000 → opc.tcp://10.100.0.35:50000
- tests/.../AbCip.IntegrationTests/AbServerFixture.cs
Host default + ResolveHost fallback: 127.0.0.1 → 10.100.0.35
- tests/.../AbLegacy.IntegrationTests/AbLegacyServerFixture.cs
Host default + ResolveEndpoint fallback: 127.0.0.1 → 10.100.0.35
XML doc comments referencing the old localhost defaults were updated in
the same pass so the class-summary documentation matches the actual
default. The override-via-env-var mechanism (MODBUS_SIM_ENDPOINT,
AB_SERVER_ENDPOINT, AB_LEGACY_ENDPOINT, S7_SIM_ENDPOINT,
OPCUA_SIM_ENDPOINT) is unchanged — pointing at a real PLC or a
locally-running container still works exactly as before.
Verification:
- Solution-wide dotnet build: 0 errors.
- S7.IntegrationTests: 3/3 pass without env-var override.
- OpcUaClient.IntegrationTests: 3/3 pass without env-var override.
- Modbus.IntegrationTests: 4/38 (same as the env-var-override run —
the 2 failures + 32 skips are pre-existing fixture-profile
mismatches unrelated to this fix).
- AbCip.IntegrationTests / AbLegacy.IntegrationTests: same results
as the env-var-override run.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -8,7 +8,7 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.AbCip.IntegrationTests;
|
|||||||
/// Reachability probe for the <c>ab_server</c> Docker container (libplctag's CIP
|
/// Reachability probe for the <c>ab_server</c> Docker container (libplctag's CIP
|
||||||
/// simulator built via <c>Docker/Dockerfile</c>) or any real AB PLC the
|
/// simulator built via <c>Docker/Dockerfile</c>) or any real AB PLC the
|
||||||
/// <c>AB_SERVER_ENDPOINT</c> env var points at. Parses
|
/// <c>AB_SERVER_ENDPOINT</c> env var points at. Parses
|
||||||
/// <c>AB_SERVER_ENDPOINT</c> (default <c>localhost:44818</c>) + TCP-connects
|
/// <c>AB_SERVER_ENDPOINT</c> (default <c>10.100.0.35:44818</c> — the shared Docker host) + TCP-connects
|
||||||
/// once at fixture construction. Tests skip via <see cref="AbServerFactAttribute"/>
|
/// once at fixture construction. Tests skip via <see cref="AbServerFactAttribute"/>
|
||||||
/// / <see cref="AbServerTheoryAttribute"/> when the port isn't live, so
|
/// / <see cref="AbServerTheoryAttribute"/> when the port isn't live, so
|
||||||
/// <c>dotnet test</c> stays green on a fresh clone without Docker running.
|
/// <c>dotnet test</c> stays green on a fresh clone without Docker running.
|
||||||
@@ -28,7 +28,10 @@ public sealed class AbServerFixture : IAsyncLifetime
|
|||||||
/// instantiate the fixture with the profile matching their compose-file service.</summary>
|
/// instantiate the fixture with the profile matching their compose-file service.</summary>
|
||||||
public AbServerProfile Profile { get; }
|
public AbServerProfile Profile { get; }
|
||||||
|
|
||||||
public string Host { get; } = "127.0.0.1";
|
// 10.100.0.35 = the shared Docker host (see CLAUDE.md "Docker Workflow"). Migrated
|
||||||
|
// off this VM's 127.0.0.1 on 2026-04-28 alongside the rest of the Docker-host move.
|
||||||
|
// Override via AB_SERVER_ENDPOINT to point at a real PLC or a locally-running container.
|
||||||
|
public string Host { get; } = "10.100.0.35";
|
||||||
public int Port { get; } = AbServerProfile.DefaultPort;
|
public int Port { get; } = AbServerProfile.DefaultPort;
|
||||||
|
|
||||||
public AbServerFixture() : this(KnownProfiles.ControlLogix) { }
|
public AbServerFixture() : this(KnownProfiles.ControlLogix) { }
|
||||||
@@ -59,7 +62,7 @@ public sealed class AbServerFixture : IAsyncLifetime
|
|||||||
TcpProbe(ResolveHost(), ResolvePort());
|
TcpProbe(ResolveHost(), ResolvePort());
|
||||||
|
|
||||||
private static string ResolveHost() =>
|
private static string ResolveHost() =>
|
||||||
Environment.GetEnvironmentVariable(EndpointEnvVar)?.Split(':', 2)[0] ?? "127.0.0.1";
|
Environment.GetEnvironmentVariable(EndpointEnvVar)?.Split(':', 2)[0] ?? "10.100.0.35";
|
||||||
|
|
||||||
private static int ResolvePort()
|
private static int ResolvePort()
|
||||||
{
|
{
|
||||||
@@ -84,7 +87,7 @@ public sealed class AbServerFixture : IAsyncLifetime
|
|||||||
|
|
||||||
/// <summary>
|
/// <summary>
|
||||||
/// <c>[Fact]</c>-equivalent that skips when ab_server isn't reachable — accepts a
|
/// <c>[Fact]</c>-equivalent that skips when ab_server isn't reachable — accepts a
|
||||||
/// live Docker listener on <c>localhost:44818</c> or an <c>AB_SERVER_ENDPOINT</c>
|
/// live Docker listener on <c>10.100.0.35:44818</c> or an <c>AB_SERVER_ENDPOINT</c>
|
||||||
/// override pointing at a real PLC.
|
/// override pointing at a real PLC.
|
||||||
/// </summary>
|
/// </summary>
|
||||||
public sealed class AbServerFactAttribute : FactAttribute
|
public sealed class AbServerFactAttribute : FactAttribute
|
||||||
|
|||||||
@@ -18,7 +18,7 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.IntegrationTests;
|
|||||||
/// Env-var overrides:
|
/// Env-var overrides:
|
||||||
/// <list type="bullet">
|
/// <list type="bullet">
|
||||||
/// <item><c>AB_LEGACY_ENDPOINT</c> — <c>host:port</c> of the PCCC-mode simulator.
|
/// <item><c>AB_LEGACY_ENDPOINT</c> — <c>host:port</c> of the PCCC-mode simulator.
|
||||||
/// Defaults to <c>localhost:44818</c> (EtherNet/IP port; ab_server's PCCC
|
/// Defaults to <c>10.100.0.35:44818</c> — the shared Docker host (EtherNet/IP port; ab_server's PCCC
|
||||||
/// emulation exposes PCCC-over-CIP on the same port as CIP itself).</item>
|
/// emulation exposes PCCC-over-CIP on the same port as CIP itself).</item>
|
||||||
/// <item><c>AB_LEGACY_CIP_PATH</c> — routing path appended to the <c>ab://host:port/</c>
|
/// <item><c>AB_LEGACY_CIP_PATH</c> — routing path appended to the <c>ab://host:port/</c>
|
||||||
/// URI. Defaults to <c>1,0</c> (port-1/slot-0 backplane), required by ab_server
|
/// URI. Defaults to <c>1,0</c> (port-1/slot-0 backplane), required by ab_server
|
||||||
@@ -50,7 +50,10 @@ public sealed class AbLegacyServerFixture : IAsyncLifetime
|
|||||||
/// </summary>
|
/// </summary>
|
||||||
public const string DefaultCipPath = "1,0";
|
public const string DefaultCipPath = "1,0";
|
||||||
|
|
||||||
public string Host { get; } = "127.0.0.1";
|
// 10.100.0.35 = the shared Docker host (see CLAUDE.md "Docker Workflow"). Migrated
|
||||||
|
// off this VM's 127.0.0.1 on 2026-04-28 alongside the rest of the Docker-host move.
|
||||||
|
// Override via AB_LEGACY_ENDPOINT to point at a real PLC or a locally-running container.
|
||||||
|
public string Host { get; } = "10.100.0.35";
|
||||||
public int Port { get; } = DefaultPort;
|
public int Port { get; } = DefaultPort;
|
||||||
|
|
||||||
/// <summary>CIP routing path portion of the device URI (after the <c>/</c> separator).
|
/// <summary>CIP routing path portion of the device URI (after the <c>/</c> separator).
|
||||||
@@ -105,7 +108,7 @@ public sealed class AbLegacyServerFixture : IAsyncLifetime
|
|||||||
private static (string Host, int Port) ResolveEndpoint()
|
private static (string Host, int Port) ResolveEndpoint()
|
||||||
{
|
{
|
||||||
var raw = Environment.GetEnvironmentVariable(EndpointEnvVar);
|
var raw = Environment.GetEnvironmentVariable(EndpointEnvVar);
|
||||||
if (raw is null) return ("127.0.0.1", DefaultPort);
|
if (raw is null) return ("10.100.0.35", DefaultPort);
|
||||||
var parts = raw.Split(':', 2);
|
var parts = raw.Split(':', 2);
|
||||||
var port = parts.Length == 2 && int.TryParse(parts[1], out var p) ? p : DefaultPort;
|
var port = parts.Length == 2 && int.TryParse(parts[1], out var p) ? p : DefaultPort;
|
||||||
return (parts[0], port);
|
return (parts[0], port);
|
||||||
|
|||||||
@@ -5,7 +5,7 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests;
|
|||||||
/// <summary>
|
/// <summary>
|
||||||
/// Reachability probe for a Modbus TCP simulator (pymodbus in Docker, see
|
/// Reachability probe for a Modbus TCP simulator (pymodbus in Docker, see
|
||||||
/// <c>Docker/docker-compose.yml</c>) or a real PLC. Parses
|
/// <c>Docker/docker-compose.yml</c>) or a real PLC. Parses
|
||||||
/// <c>MODBUS_SIM_ENDPOINT</c> (default <c>localhost:5020</c> per PR 43) and TCP-connects once at
|
/// <c>MODBUS_SIM_ENDPOINT</c> (default <c>10.100.0.35:5020</c> — the shared Docker host) and TCP-connects once at
|
||||||
/// fixture construction. Each test checks <see cref="SkipReason"/> and calls
|
/// fixture construction. Each test checks <see cref="SkipReason"/> and calls
|
||||||
/// <c>Assert.Skip</c> when the endpoint was unreachable, so a dev box without a running
|
/// <c>Assert.Skip</c> when the endpoint was unreachable, so a dev box without a running
|
||||||
/// simulator still passes `dotnet test` cleanly — matches the Galaxy live-smoke pattern in
|
/// simulator still passes `dotnet test` cleanly — matches the Galaxy live-smoke pattern in
|
||||||
@@ -29,8 +29,11 @@ public sealed class ModbusSimulatorFixture : IAsyncDisposable
|
|||||||
// PR 43: default port is 5020 (pymodbus convention) instead of 502 (Modbus standard).
|
// PR 43: default port is 5020 (pymodbus convention) instead of 502 (Modbus standard).
|
||||||
// Picking 5020 sidesteps the privileged-port admin requirement on Windows + matches the
|
// Picking 5020 sidesteps the privileged-port admin requirement on Windows + matches the
|
||||||
// port baked into the pymodbus simulator JSON profiles in Docker/profiles/. Override with
|
// port baked into the pymodbus simulator JSON profiles in Docker/profiles/. Override with
|
||||||
// MODBUS_SIM_ENDPOINT to point at a real PLC on its native port 502.
|
// MODBUS_SIM_ENDPOINT to point at a real PLC on its native port 502, or to a
|
||||||
private const string DefaultEndpoint = "localhost:5020";
|
// locally-running container if the shared host is unavailable.
|
||||||
|
// 10.100.0.35 = the shared Docker host (see CLAUDE.md "Docker Workflow"). Migrated
|
||||||
|
// off this VM's localhost on 2026-04-28 alongside the rest of the Docker-host move.
|
||||||
|
private const string DefaultEndpoint = "10.100.0.35:5020";
|
||||||
private const string EndpointEnvVar = "MODBUS_SIM_ENDPOINT";
|
private const string EndpointEnvVar = "MODBUS_SIM_ENDPOINT";
|
||||||
|
|
||||||
public string Host { get; }
|
public string Host { get; }
|
||||||
|
|||||||
@@ -6,7 +6,7 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.IntegrationTests;
|
|||||||
/// Reachability probe for an <c>opc-plc</c> simulator (Microsoft Industrial IoT's
|
/// Reachability probe for an <c>opc-plc</c> simulator (Microsoft Industrial IoT's
|
||||||
/// OPC UA PLC from <c>mcr.microsoft.com/iotedge/opc-plc</c>) or any real OPC UA
|
/// OPC UA PLC from <c>mcr.microsoft.com/iotedge/opc-plc</c>) or any real OPC UA
|
||||||
/// server the <c>OPCUA_SIM_ENDPOINT</c> env var points at. Parses
|
/// server the <c>OPCUA_SIM_ENDPOINT</c> env var points at. Parses
|
||||||
/// <c>OPCUA_SIM_ENDPOINT</c> (default <c>opc.tcp://localhost:50000</c>),
|
/// <c>OPCUA_SIM_ENDPOINT</c> (default <c>opc.tcp://10.100.0.35:50000</c> — the shared Docker host),
|
||||||
/// TCP-connects to the resolved host:port at collection init, and records a
|
/// TCP-connects to the resolved host:port at collection init, and records a
|
||||||
/// <see cref="SkipReason"/> on failure. Tests call <c>Assert.Skip</c> on that, so
|
/// <see cref="SkipReason"/> on failure. Tests call <c>Assert.Skip</c> on that, so
|
||||||
/// `dotnet test` stays green when Docker isn't running the simulator — mirrors the
|
/// `dotnet test` stays green when Docker isn't running the simulator — mirrors the
|
||||||
@@ -32,7 +32,11 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.IntegrationTests;
|
|||||||
/// </remarks>
|
/// </remarks>
|
||||||
public sealed class OpcPlcFixture : IAsyncDisposable
|
public sealed class OpcPlcFixture : IAsyncDisposable
|
||||||
{
|
{
|
||||||
private const string DefaultEndpoint = "opc.tcp://localhost:50000";
|
// 10.100.0.35 = the shared Docker host (see CLAUDE.md "Docker Workflow"). Migrated
|
||||||
|
// off this VM's localhost on 2026-04-28 alongside the rest of the Docker-host move.
|
||||||
|
// Override via OPCUA_SIM_ENDPOINT to point at a different host or a locally-running
|
||||||
|
// opc-plc instance.
|
||||||
|
private const string DefaultEndpoint = "opc.tcp://10.100.0.35:50000";
|
||||||
private const string EndpointEnvVar = "OPCUA_SIM_ENDPOINT";
|
private const string EndpointEnvVar = "OPCUA_SIM_ENDPOINT";
|
||||||
|
|
||||||
/// <summary>Full <c>opc.tcp://host:port</c> URL the driver session should connect to.</summary>
|
/// <summary>Full <c>opc.tcp://host:port</c> URL the driver session should connect to.</summary>
|
||||||
|
|||||||
@@ -5,7 +5,7 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.S7.IntegrationTests;
|
|||||||
/// <summary>
|
/// <summary>
|
||||||
/// Reachability probe for the python-snap7 simulator Docker container (see
|
/// Reachability probe for the python-snap7 simulator Docker container (see
|
||||||
/// <c>Docker/docker-compose.yml</c>) or a real S7 PLC. Parses <c>S7_SIM_ENDPOINT</c>
|
/// <c>Docker/docker-compose.yml</c>) or a real S7 PLC. Parses <c>S7_SIM_ENDPOINT</c>
|
||||||
/// (default <c>localhost:1102</c>) + TCP-connects once at fixture construction.
|
/// (default <c>10.100.0.35:1102</c> — the shared Docker host) + TCP-connects once at fixture construction.
|
||||||
/// Tests check <see cref="SkipReason"/> + call <c>Assert.Skip</c> when unreachable, so
|
/// Tests check <see cref="SkipReason"/> + call <c>Assert.Skip</c> when unreachable, so
|
||||||
/// `dotnet test` stays green on a fresh box without the simulator installed —
|
/// `dotnet test` stays green on a fresh box without the simulator installed —
|
||||||
/// mirrors the <c>ModbusSimulatorFixture</c> pattern.
|
/// mirrors the <c>ModbusSimulatorFixture</c> pattern.
|
||||||
@@ -35,7 +35,9 @@ public sealed class Snap7ServerFixture : IAsyncDisposable
|
|||||||
{
|
{
|
||||||
// Default 1102 (non-privileged) matches Docker/server.py. Override with
|
// Default 1102 (non-privileged) matches Docker/server.py. Override with
|
||||||
// S7_SIM_ENDPOINT to point at a real PLC on its native 102.
|
// S7_SIM_ENDPOINT to point at a real PLC on its native 102.
|
||||||
private const string DefaultEndpoint = "localhost:1102";
|
// 10.100.0.35 = the shared Docker host (see CLAUDE.md "Docker Workflow"). Migrated
|
||||||
|
// off this VM's localhost on 2026-04-28 alongside the rest of the Docker-host move.
|
||||||
|
private const string DefaultEndpoint = "10.100.0.35:1102";
|
||||||
private const string EndpointEnvVar = "S7_SIM_ENDPOINT";
|
private const string EndpointEnvVar = "S7_SIM_ENDPOINT";
|
||||||
|
|
||||||
public string Host { get; }
|
public string Host { get; }
|
||||||
|
|||||||
Reference in New Issue