docs(heidenhain): honest provenance for alarm class/group codes (#853)
v2-ci / unit-tests (push) Has been cancelled

No public source exists for DNC_ERROR_CLASS / DNC_ERROR_GROUP or their numbers
(the table was written from memory). The iTNC 530 Technical Manual's PLC error
table documents the same class and group NAMES without codes; three real
iTNC 530 records corroborate 7/4, 7/3 and 1/3. DNC and LSV2 numberings are
known to differ (ProgramStatus vs R_RI 26), so the numbers stay unproven.
Docs/comments only; no behaviour change.

Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
This commit is contained in:
Joseph Doherty
2026-11-13 00:36:11 -05:00
parent a4ce417d11
commit 2e537dc6ca
3 changed files with 28 additions and 12 deletions
+1 -1
View File
@@ -370,7 +370,7 @@ panel with the NAT/IPv6-zone/loose-match caveats) / CLI `--validate-host-name`.
allowlist is unchanged. FOCAS transition rules; identity = class+group+number+TEXT (numbers repeat, `-1`). A failed walk
(refusal/overflow/comms) is quality-only, never a clear. ⚠️ Ack is LOCAL-ONLY (`AcknowledgeAsync` no-op success) —
never add an LSV2 ack/write to the allowlist for it. Class/group codes have no invented SEVERITIES; since #839 they
carry HEIDENHAIN DNC-interface names (labels + browse leaves only — corroborated by one iTNC 530 record, else
carry class/group names (labels + browse leaves only; names per the iTNC 530 PET table, numbers from memory — corroborated by three iTNC 530 records, else
hardware-unproven) and set the Part 9 `ConditionClass` (class 5 ⇒ Safety; group 1/2 ⇒ Process; 4/5 ⇒ System; else Base)
via the new optional `AlarmEventArgs.ConditionClass` (projector keeps it across class-less events; node manager writes
it; rebuild carries it). The browse picker offers `AlarmConditions/` selector leaves; alarms no selector claims are