feat(heidenhain): controller alarms as native Part 9 conditions; rediscovery on identity change (#831)

- ALARM: selectors (HeidenhainAlarmSelector, Contracts): ALARM:*, ALARM:OTHER,
  ALARM:CLASS=<r>[/GROUP=<r>][/NUMBER=<r>] (<r> = n | lo..hi; negative numbers allowed).
  An ALARM: address and the cross-driver alarm object only work together — the factory
  refuses either alone, so editor, save path, CSV and deploy inspector agree. Data type
  fixed Boolean; never a value (ReadAsync BadNotSupported), never in a data subscription.
- HeidenhainDriver implements IAlarmSource: one condition per ALARM: tag at its RawPath,
  driven by the SAME allowlisted R_RI 27/28 walk on the control's single loop, on the new
  Polling.AlarmMs cadence (default 2000 ms, only for controls carrying an ALARM: tag).
  FOCAS #647 transition rules (Raise / Retrigger / Clear), identity = class+group+number+text,
  deterministic display order, told-record on the driver instance, recorded only while a
  handler listens. A failed walk (refusal, overflow, comms loss) is quality-only, never a clear.
- Acknowledge is LOCAL-ONLY: AcknowledgeAsync is a no-op success (FOCAS/MTConnect posture);
  Lsv2ReadOnlyPolicy is unchanged — no ack or write request exists.
- Opt-in per tag, no driver flag (FOCAS #647 / MTConnect #626 precedent); Alarms/* arrays unchanged.
- IRediscoverable: a reconnect whose R_VR identity (model / NC / PLC / options) differs from
  the previous session raises OnRediscoveryNeeded once (advisory re-browse chip). No extra traffic.
- AdminUI: Heidenhain joins NativeAlarmModel's alarm drivers; the typed editor fixes ALARM:
  tags at Boolean and seeds/drops the alarm object with the selector; driver form gains
  "Alarm conditions (ms)". (HeidenhainDriverFormModel also carries the #830 credential-notice change.)

Tests: HeidenhainAlarmTests (grammar, pairing, rules, simulator e2e with the captured iTNC 530
alarm record, local-only ack = zero bytes sent, quality-only outage/refusal, rediscovery),
Runtime.Tests HeidenhainNativeAlarmEndToEndTests (real DriverHostActor condition), a
DraftValidator case, and the NativeAlarmDriverSetGuard now scans the Heidenhain driver.
This commit is contained in:
Joseph Doherty
2026-11-11 01:37:41 -05:00
parent 5bbe1e3c7a
commit 2b0eed1a8f
22 changed files with 1379 additions and 31 deletions
+10 -1
View File
@@ -61,7 +61,9 @@ design treated it as an implementation detail.
⚠️ **Consequence to know before you rely on rediscovery:** **AbCip and FOCAS browse a live backend but
implement no `IRediscoverable`, so they have no tag-change signal at all** — a PLC program re-download
or a CNC option install is invisible until someone re-browses the device by hand. Galaxy, TwinCAT,
MTConnect and MQTT raise natively and are unaffected. If that coverage matters later, reach for an
MTConnect and MQTT raise natively and are unaffected. Heidenhain (#831) raises on the event-driven shape this
recommends: a reconnect whose `R_VR` identity (model / NC / PLC version / options) differs from the previous session —
no timer, no extra request. If that coverage matters later, reach for an
event-driven signal, or one that runs when something *else* already indicates change (a reconnect, a
deploy) — not a wall-clock timer. Removed with the feature: `TagSetDrift`/`TagSetDriftDetector`,
`DriverInstanceActor`'s drift timer, and `ITagDiscovery.AuthoredDiscoveryRefs` /
@@ -319,6 +321,13 @@ host logger factory (wired in `DriverFactoryBootstrap`; the FOCAS and TwinCAT fa
`BadConfigurationError` on that role's reads only
(`HeidenhainCredentialPersisted`). Hardware-unproven: the in-process simulator + Java golden vectors are the evidence;
`Category=LiveIntegration` (`HEIDENHAIN_LSV2_HOST`) is the commissioning gate. `docs/drivers/Heidenhain.md`.
- **Heidenhain alarms (#831):** an `ALARM:` selector (`*`, `OTHER`, `CLASS=<r>[/GROUP=<r>][/NUMBER=<r>]`, `<r>` = `n` |
`lo..hi`) + the `alarm` object = ONE condition at the RawPath (either alone is REFUSED by the factory, so editor/save
path/CSV/deploy agree; data type fixed `Boolean`). Opt-in per tag, no driver flag (FOCAS #647 precedent); `Alarms/*`
arrays unchanged. Walked on `Polling.AlarmMs` (2 s) by the control's single loop with the SAME `R_RI 27/28` — the
allowlist is unchanged. FOCAS transition rules; identity = class+group+number+TEXT (numbers repeat, `-1`). A failed walk
(refusal/overflow/comms) is quality-only, never a clear. ⚠️ Ack is LOCAL-ONLY (`AcknowledgeAsync` no-op success) —
never add an LSV2 ack/write to the allowlist for it. Class/group codes have no invented names or severities.
- **Native condition state survives a full rebuild (#641):** `RebuildAddressSpace` captures each NATIVE condition's
live node state (client acks included), the same-apply re-materialise restores it, and `CompleteAddressSpaceApply`
(called by `OpcUaPublishActor` at the end of every apply) reports ONE event per restored off-normal condition and