fix(drivers): #630 review - AbCip disposes alarm projection + clears tag tables, join not abortable by init token; S7 swaps Plc under _gate; doc rationale
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
This commit is contained in:
@@ -229,6 +229,33 @@ public sealed class AbCipAlarmProjectionTests
|
||||
}
|
||||
|
||||
/// <summary>Waits for <paramref name="more"/> further reads of the fake runtime (a processed-count wait).</summary>
|
||||
/// <summary>
|
||||
/// #630 — a re-Initialize on a live driver must dispose the alarm projection's poll loop rather
|
||||
/// than leave it running (it would keep raising duplicate alarm events through this driver).
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public async Task Reinitialize_Stops_The_Previous_Projection_Poll_Loop()
|
||||
{
|
||||
var factory = new FakeAbCipTagFactory();
|
||||
var drv = new AbCipDriver(Options(enabled: true), "drv-1", factory);
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
await drv.SubscribeAlarmsAsync(["HighTemp"], CancellationToken.None);
|
||||
|
||||
await WaitForTagCreation(factory, "HighTemp");
|
||||
var tag = factory.Tags["HighTemp"];
|
||||
// Positive control: the loop is demonstrably polling before the re-init.
|
||||
await WaitForMoreReadsAsync(factory, "HighTemp", 3);
|
||||
|
||||
await drv.InitializeAsync("{}", CancellationToken.None);
|
||||
|
||||
int Reads() => factory.Tags.Values.Sum(t => t.ReadCount); // the loop may re-create its runtime on the new device state
|
||||
var frozen = Reads();
|
||||
await Task.Delay(300); // ~15 poll intervals; a live loop would advance the count
|
||||
Reads().ShouldBe(frozen);
|
||||
|
||||
await drv.ShutdownAsync(CancellationToken.None);
|
||||
}
|
||||
|
||||
private static async Task WaitForMoreReadsAsync(FakeAbCipTagFactory factory, string tagName, int more)
|
||||
{
|
||||
var tag = factory.Tags[tagName];
|
||||
|
||||
Reference in New Issue