Phase 3 PR 62 -- Siemens S7 native driver project scaffold (S7comm via S7netplus). First non-Modbus in-process driver. Creates src/ZB.MOM.WW.OtOpcUa.Driver.S7 (.NET 10, x64 -- S7netplus is managed, no bitness constraint like MXAccess) + tests/ZB.MOM.WW.OtOpcUa.Driver.S7.Tests + slnx entries. Depends on S7netplus 0.20.0 which is the latest version on NuGet resolvable in this cache (0.21.0 per driver-specs.md is not yet published; 0.20.0 covers the same Plc+CpuType+ReadAsync surface). S7DriverOptions captures the connection settings documented in driver-specs.md \u00A75: Host, Port (default 102 ISO-on-TCP), CpuType (default S71500 per most-common deployment), Rack=0, Slot=0 (S7-1200/1500 onboard PN convention; S7-300/400 operators must override to slot 2 or 3), Timeout=5s, Tags list + Probe settings with default MW0 probe address. S7TagDefinition uses S7.Net-style address strings (DB1.DBW0, M0.0, I0.0, QD4) with an S7DataType enum (Bool, Byte, Int16, UInt16, Int32, UInt32, Int64, UInt64, Float32, Float64, String, DateTime -- the full type matrix from the spec); StringLength defaults to 254 (S7 STRING max). S7Driver implements the IDriver-only subset per the PR plan: InitializeAsync opens a managed Plc with the configured CpuType + Host + Rack + Slot, pins WriteTimeout / ReadTimeout on the underlying TcpClient, awaits Plc.OpenAsync with a linked CTS bounded by Options.Timeout so the ISO handshake itself respects the configured bound; health transitions Unknown -> Initializing -> Healthy on success or Unknown -> Initializing -> Faulted on handshake failure, with a best-effort Plc.Close() on the faulted path so retries don't leak the TcpClient. ShutdownAsync closes the Plc and flips health back to Unknown. DisposeAsync routes through ShutdownAsync + disposes the SemaphoreSlim. Internal Gate + Plc accessors are exposed to the test project (InternalsVisibleTo) so PRs 63-65 can stack read/write/subscribe on the same serialization semaphore per the S7netplus documented 'one Plc per PLC, SemaphoreSlim-serialized' pattern. ITagDiscovery, IReadable, IWritable, ISubscribable, IHostConnectivityProbe are all deliberately omitted from this PR -- they depend on the S7AddressParser (PR 63) and land sequenced in PRs 64-65. Unit tests (S7DriverScaffoldTests, 5 facts): default options target S7-1500 / port 102 / slot 0, default probe interval 5s, tag defaults to writable with StringLength 254, driver reports DriverType=S7 + Unknown health pre-init, Initialize against RFC-5737 reserved IP 192.0.2.1 with 250ms timeout transitions to Faulted and throws (tests the connect-failure path doesn't leave the driver in an ambiguous state). 5/5 pass. dotnet build ZB.MOM.WW.OtOpcUa.slnx: 0 errors. No regression in Modbus / Galaxy suites. PR 63 ships S7AddressParser next, PR 64 wires IReadable/IWritable over S7netplus, PR 65 adds discovery + polling-overlay subscribe + probe.
This commit is contained in:
119
src/ZB.MOM.WW.OtOpcUa.Driver.S7/S7Driver.cs
Normal file
119
src/ZB.MOM.WW.OtOpcUa.Driver.S7/S7Driver.cs
Normal file
@@ -0,0 +1,119 @@
|
||||
using S7.Net;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.S7;
|
||||
|
||||
/// <summary>
|
||||
/// Siemens S7 native driver — speaks S7comm over ISO-on-TCP (port 102) via the S7netplus
|
||||
/// library. First implementation of <see cref="IDriver"/> for an in-process .NET Standard
|
||||
/// PLC protocol that is NOT Modbus, validating that the v2 driver-capability interfaces
|
||||
/// generalize beyond Modbus + Galaxy.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para>
|
||||
/// PR 62 ships the scaffold: <see cref="IDriver"/> only (Initialize / Reinitialize /
|
||||
/// Shutdown / GetHealth). <see cref="ITagDiscovery"/>, <see cref="IReadable"/>,
|
||||
/// <see cref="IWritable"/>, <see cref="ISubscribable"/>, <see cref="IHostConnectivityProbe"/>
|
||||
/// land in PRs 63-65 once the address parser (PR 63) is in place.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// <b>Single-connection policy</b>: S7netplus documented pattern is one
|
||||
/// <c>Plc</c> instance per PLC, serialized with a <see cref="SemaphoreSlim"/>.
|
||||
/// Parallelising reads against a single S7 CPU doesn't help — the CPU scans the
|
||||
/// communication mailbox at most once per cycle (2-10 ms) and queues concurrent
|
||||
/// requests wire-side anyway. Multiple client-side connections just waste the CPU's
|
||||
/// 8-64 connection-resource budget.
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
public sealed class S7Driver(S7DriverOptions options, string driverInstanceId)
|
||||
: IDriver, IDisposable, IAsyncDisposable
|
||||
{
|
||||
private readonly S7DriverOptions _options = options;
|
||||
private readonly SemaphoreSlim _gate = new(1, 1);
|
||||
|
||||
/// <summary>
|
||||
/// Per-connection gate. Internal so PRs 63-65 (read/write/subscribe) can serialize on
|
||||
/// the same semaphore without exposing it publicly. Single-connection-per-PLC is a
|
||||
/// hard requirement of S7netplus — see class remarks.
|
||||
/// </summary>
|
||||
internal SemaphoreSlim Gate => _gate;
|
||||
|
||||
/// <summary>
|
||||
/// Active S7.Net PLC connection. Null until <see cref="InitializeAsync"/> returns; null
|
||||
/// after <see cref="ShutdownAsync"/>. Read-only outside this class; PR 64's Read/Write
|
||||
/// will take the <see cref="_gate"/> before touching it.
|
||||
/// </summary>
|
||||
internal Plc? Plc { get; private set; }
|
||||
|
||||
private DriverHealth _health = new(DriverState.Unknown, null, null);
|
||||
private bool _disposed;
|
||||
|
||||
public string DriverInstanceId => driverInstanceId;
|
||||
public string DriverType => "S7";
|
||||
|
||||
public async Task InitializeAsync(string driverConfigJson, CancellationToken cancellationToken)
|
||||
{
|
||||
_health = new DriverHealth(DriverState.Initializing, null, null);
|
||||
try
|
||||
{
|
||||
var plc = new Plc(_options.CpuType, _options.Host, _options.Rack, _options.Slot);
|
||||
// S7netplus writes timeouts into the underlying TcpClient via Plc.WriteTimeout /
|
||||
// Plc.ReadTimeout (milliseconds). Set before OpenAsync so the handshake itself
|
||||
// honours the bound.
|
||||
plc.WriteTimeout = (int)_options.Timeout.TotalMilliseconds;
|
||||
plc.ReadTimeout = (int)_options.Timeout.TotalMilliseconds;
|
||||
|
||||
using var cts = CancellationTokenSource.CreateLinkedTokenSource(cancellationToken);
|
||||
cts.CancelAfter(_options.Timeout);
|
||||
await plc.OpenAsync(cts.Token).ConfigureAwait(false);
|
||||
|
||||
Plc = plc;
|
||||
_health = new DriverHealth(DriverState.Healthy, DateTime.UtcNow, null);
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
// Clean up a partially-constructed Plc so a retry from the caller doesn't leak
|
||||
// the TcpClient. S7netplus's Close() is best-effort and idempotent.
|
||||
try { Plc?.Close(); } catch { }
|
||||
Plc = null;
|
||||
_health = new DriverHealth(DriverState.Faulted, null, ex.Message);
|
||||
throw;
|
||||
}
|
||||
}
|
||||
|
||||
public async Task ReinitializeAsync(string driverConfigJson, CancellationToken cancellationToken)
|
||||
{
|
||||
await ShutdownAsync(cancellationToken).ConfigureAwait(false);
|
||||
await InitializeAsync(driverConfigJson, cancellationToken).ConfigureAwait(false);
|
||||
}
|
||||
|
||||
public Task ShutdownAsync(CancellationToken cancellationToken)
|
||||
{
|
||||
try { Plc?.Close(); } catch { /* best-effort — tearing down anyway */ }
|
||||
Plc = null;
|
||||
_health = new DriverHealth(DriverState.Unknown, _health.LastSuccessfulRead, null);
|
||||
return Task.CompletedTask;
|
||||
}
|
||||
|
||||
public DriverHealth GetHealth() => _health;
|
||||
|
||||
/// <summary>
|
||||
/// Approximate memory footprint. The Plc instance + one 240-960 byte PDU buffer is
|
||||
/// under 4 KB; return 0 because the <see cref="IDriver"/> contract asks for a
|
||||
/// driver-attributable growth number and S7.Net doesn't expose one.
|
||||
/// </summary>
|
||||
public long GetMemoryFootprint() => 0;
|
||||
|
||||
public Task FlushOptionalCachesAsync(CancellationToken cancellationToken) => Task.CompletedTask;
|
||||
|
||||
public void Dispose() => DisposeAsync().AsTask().GetAwaiter().GetResult();
|
||||
|
||||
public async ValueTask DisposeAsync()
|
||||
{
|
||||
if (_disposed) return;
|
||||
_disposed = true;
|
||||
try { await ShutdownAsync(CancellationToken.None).ConfigureAwait(false); }
|
||||
catch { /* disposal is best-effort */ }
|
||||
_gate.Dispose();
|
||||
}
|
||||
}
|
||||
112
src/ZB.MOM.WW.OtOpcUa.Driver.S7/S7DriverOptions.cs
Normal file
112
src/ZB.MOM.WW.OtOpcUa.Driver.S7/S7DriverOptions.cs
Normal file
@@ -0,0 +1,112 @@
|
||||
using S7NetCpuType = global::S7.Net.CpuType;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.S7;
|
||||
|
||||
/// <summary>
|
||||
/// Siemens S7 native (S7comm / ISO-on-TCP port 102) driver configuration. Bound from the
|
||||
/// driver's <c>DriverConfig</c> JSON at <c>DriverHost.RegisterAsync</c>. Unlike the Modbus
|
||||
/// driver the S7 driver uses the PLC's *native* protocol — port 102 ISO-on-TCP rather
|
||||
/// than Modbus's 502, and S7-specific area codes (DB, M, I, Q) rather than holding-
|
||||
/// register / coil tables.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para>
|
||||
/// The driver requires <b>PUT/GET communication enabled</b> in the TIA Portal
|
||||
/// hardware config for S7-1200/1500. The factory default disables PUT/GET access,
|
||||
/// so a driver configured against a freshly-flashed CPU will see a hard error
|
||||
/// (S7.Net surfaces it as <c>Plc.ReadAsync</c> returning <c>ErrorCode.Accessing</c>).
|
||||
/// The driver maps that specifically to <c>BadNotSupported</c> and flags it as a
|
||||
/// configuration alert rather than a transient fault — blind Polly retry is wasted
|
||||
/// effort when the PLC will keep refusing every request.
|
||||
/// </para>
|
||||
/// <para>
|
||||
/// See <c>docs/v2/driver-specs.md</c> §5 for the full specification.
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
public sealed class S7DriverOptions
|
||||
{
|
||||
/// <summary>PLC IP address or hostname.</summary>
|
||||
public string Host { get; init; } = "127.0.0.1";
|
||||
|
||||
/// <summary>TCP port. ISO-on-TCP is 102 on every S7 model; override only for unusual NAT setups.</summary>
|
||||
public int Port { get; init; } = 102;
|
||||
|
||||
/// <summary>
|
||||
/// CPU family. Determines the ISO-TSAP slot byte that S7.Net uses during connection
|
||||
/// setup — pick the family that matches the target PLC exactly.
|
||||
/// </summary>
|
||||
public S7NetCpuType CpuType { get; init; } = S7NetCpuType.S71500;
|
||||
|
||||
/// <summary>
|
||||
/// Hardware rack number. Almost always 0; relevant only for distributed S7-400 racks
|
||||
/// with multiple CPUs.
|
||||
/// </summary>
|
||||
public short Rack { get; init; } = 0;
|
||||
|
||||
/// <summary>
|
||||
/// CPU slot. Conventions per family: S7-300 = slot 2, S7-400 = slot 2 or 3,
|
||||
/// S7-1200 / S7-1500 = slot 0 (onboard PN). S7.Net uses this to build the remote
|
||||
/// TSAP. Wrong slot → connection refused during handshake.
|
||||
/// </summary>
|
||||
public short Slot { get; init; } = 0;
|
||||
|
||||
/// <summary>Connect + per-operation timeout.</summary>
|
||||
public TimeSpan Timeout { get; init; } = TimeSpan.FromSeconds(5);
|
||||
|
||||
/// <summary>Pre-declared tag map. S7 has a symbol-table protocol but S7.Net does not expose it, so the driver operates off a static tag list configured per-site. Address grammar documented in S7AddressParser (PR 63).</summary>
|
||||
public IReadOnlyList<S7TagDefinition> Tags { get; init; } = [];
|
||||
|
||||
/// <summary>
|
||||
/// Background connectivity-probe settings. When enabled, the driver runs a tick loop
|
||||
/// that issues a cheap read against <see cref="S7ProbeOptions.ProbeAddress"/> every
|
||||
/// <see cref="S7ProbeOptions.Interval"/> and raises <c>OnHostStatusChanged</c> on
|
||||
/// Running ↔ Stopped transitions.
|
||||
/// </summary>
|
||||
public S7ProbeOptions Probe { get; init; } = new();
|
||||
}
|
||||
|
||||
public sealed class S7ProbeOptions
|
||||
{
|
||||
public bool Enabled { get; init; } = true;
|
||||
public TimeSpan Interval { get; init; } = TimeSpan.FromSeconds(5);
|
||||
public TimeSpan Timeout { get; init; } = TimeSpan.FromSeconds(2);
|
||||
|
||||
/// <summary>
|
||||
/// Address to probe for liveness. DB1.DBW0 is the convention if the PLC project
|
||||
/// reserves a small fingerprint DB for health checks (per <c>docs/v2/s7.md</c>);
|
||||
/// if not, pick any valid Merker word like <c>MW0</c>.
|
||||
/// </summary>
|
||||
public string ProbeAddress { get; init; } = "MW0";
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// One S7 variable as exposed by the driver. Addresses use S7.Net syntax — see
|
||||
/// <c>S7AddressParser</c> (PR 63) for the grammar.
|
||||
/// </summary>
|
||||
/// <param name="Name">Tag name; OPC UA browse name + driver full reference.</param>
|
||||
/// <param name="Address">S7 address string, e.g. <c>DB1.DBW0</c>, <c>M0.0</c>, <c>I0.0</c>, <c>QD4</c>. Grammar documented in <c>S7AddressParser</c> (PR 63).</param>
|
||||
/// <param name="DataType">Logical data type — drives the underlying S7.Net read/write width.</param>
|
||||
/// <param name="Writable">When true the driver accepts writes for this tag.</param>
|
||||
/// <param name="StringLength">For <c>DataType = String</c>: S7-string max length. Default 254 (S7 max).</param>
|
||||
public sealed record S7TagDefinition(
|
||||
string Name,
|
||||
string Address,
|
||||
S7DataType DataType,
|
||||
bool Writable = true,
|
||||
int StringLength = 254);
|
||||
|
||||
public enum S7DataType
|
||||
{
|
||||
Bool,
|
||||
Byte,
|
||||
Int16,
|
||||
UInt16,
|
||||
Int32,
|
||||
UInt32,
|
||||
Int64,
|
||||
UInt64,
|
||||
Float32,
|
||||
Float64,
|
||||
String,
|
||||
DateTime,
|
||||
}
|
||||
@@ -0,0 +1,27 @@
|
||||
<Project Sdk="Microsoft.NET.Sdk">
|
||||
|
||||
<PropertyGroup>
|
||||
<TargetFramework>net10.0</TargetFramework>
|
||||
<Nullable>enable</Nullable>
|
||||
<ImplicitUsings>enable</ImplicitUsings>
|
||||
<LangVersion>latest</LangVersion>
|
||||
<TreatWarningsAsErrors>true</TreatWarningsAsErrors>
|
||||
<GenerateDocumentationFile>true</GenerateDocumentationFile>
|
||||
<NoWarn>$(NoWarn);CS1591</NoWarn>
|
||||
<RootNamespace>ZB.MOM.WW.OtOpcUa.Driver.S7</RootNamespace>
|
||||
<AssemblyName>ZB.MOM.WW.OtOpcUa.Driver.S7</AssemblyName>
|
||||
</PropertyGroup>
|
||||
|
||||
<ItemGroup>
|
||||
<ProjectReference Include="..\ZB.MOM.WW.OtOpcUa.Core.Abstractions\ZB.MOM.WW.OtOpcUa.Core.Abstractions.csproj"/>
|
||||
</ItemGroup>
|
||||
|
||||
<ItemGroup>
|
||||
<PackageReference Include="S7netplus" Version="0.20.0"/>
|
||||
</ItemGroup>
|
||||
|
||||
<ItemGroup>
|
||||
<InternalsVisibleTo Include="ZB.MOM.WW.OtOpcUa.Driver.S7.Tests"/>
|
||||
</ItemGroup>
|
||||
|
||||
</Project>
|
||||
Reference in New Issue
Block a user