513fa1aa16
Comment/XML-doc changes only: - add summaries to ~10k test methods, fixtures, fakes and helpers (+ <param> on theories, <returns> on async Task methods, <inheritdoc/> on interface implementations the checker can resolve) - strip ~2.6k project-tracking references (WP*, P*-*, row-NN, Task N, #NN, Component-0NN) from comments, keeping the explanatory text; reword false positives in comments only - real docs on fakes implementing BCL/library interfaces (IDisposable, ILogger, IOptionsMonitor, IAsyncLifetime) - reword the last 5 src/ false positives (CWE-1236, failures-1, year-0001, M365) Only non-comment edits: four one-line nested classes split across lines so members can carry docs. Build 0 errors / 0 warnings.
44 lines
1.9 KiB
C#
44 lines
1.9 KiB
C#
using Microsoft.Extensions.Logging.Abstractions;
|
|
using NSubstitute;
|
|
using ZB.MOM.WW.ScadaBridge.Commons.Interfaces.Protocol;
|
|
using ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Adapters;
|
|
|
|
namespace ZB.MOM.WW.ScadaBridge.DataConnectionLayer.Tests.Adapters;
|
|
|
|
/// <summary>
|
|
/// <see cref="OpcUaDataConnection"/> implements
|
|
/// <see cref="IBrowsableDataConnection"/> as a one-line forwarder onto the
|
|
/// underlying <see cref="IOpcUaClient"/>. This guards that wiring — the
|
|
/// adapter must not add its own browse semantics; all browse behaviour lives
|
|
/// in the client (and is covered by RealOpcUaClient's own tests).
|
|
/// </summary>
|
|
public class OpcUaDataConnectionBrowseTests
|
|
{
|
|
/// <summary>Verifies that browsing children is forwarded to the underlying OPC UA client.</summary>
|
|
/// <returns>A task that represents the asynchronous operation.</returns>
|
|
[Fact]
|
|
public async Task BrowseChildrenAsync_ForwardsToUnderlyingClient()
|
|
{
|
|
var client = Substitute.For<IOpcUaClient>();
|
|
var factory = Substitute.For<IOpcUaClientFactory>();
|
|
factory.Create().Returns(client);
|
|
client.IsConnected.Returns(true);
|
|
|
|
var expected = new BrowseChildrenResult(
|
|
new[] { new BrowseNode("ns=2;s=X", "X", BrowseNodeClass.Variable, false) },
|
|
Truncated: false);
|
|
client.BrowseChildrenAsync("ns=2;s=Parent", Arg.Any<string?>(), Arg.Any<CancellationToken>())
|
|
.Returns(expected);
|
|
|
|
var adapter = new OpcUaDataConnection(factory, NullLogger<OpcUaDataConnection>.Instance);
|
|
// ConnectAsync installs the IOpcUaClient instance on the adapter; the
|
|
// forwarder dereferences that field directly.
|
|
await adapter.ConnectAsync(new Dictionary<string, string>());
|
|
|
|
var actual = await adapter.BrowseChildrenAsync("ns=2;s=Parent");
|
|
|
|
Assert.Same(expected, actual);
|
|
await client.Received(1).BrowseChildrenAsync("ns=2;s=Parent", Arg.Any<string?>(), Arg.Any<CancellationToken>());
|
|
}
|
|
}
|