Async cancellation hygiene, fire-and-forget observability, retry/shutdown semantics, and audit-row coverage across 9 modules. Highlights: Cancellation & lifecycle: - AuditLog-006: SqliteAuditWriter.Dispose hops to thread pool, escaping the captured SyncContext that risked sync-over-async deadlock. - AuditLog-010: SiteAuditTelemetryActor owns a private lifecycle CTS, threaded through drain paths instead of CancellationToken.None. - Comm-019: CentralCommunicationActor adds lifecycle CTS for repo calls. - Host-019: Migration StartupRetry forwards ApplicationStopping so SIGTERM during the bounded-retry window aborts cleanly. Cursor / retry / counter correctness: - AuditLog-004: SiteAuditReconciliationActor's cursor now holds at `since` when any row's idempotent insert is still being retried (per-EventId retry counter, MaxPermanentInsertAttempts=5 escape valve with LogCritical abandon). No more silent abandonment of permanently-failing rows. - ConfigDB-019: Dropped the catch-and-continue on EnsureLookaheadAsync's SPLIT loop — by class-doc construction the catch could only mask real failures and let the next iteration create permanent partition holes. - HM-017/018: HealthReportSender + CentralHealthReportLoop snapshot per-interval counters before sending, restore via new ISiteHealthCollector.AddIntervalCounters on transport failure so counts aren't silently lost. Fire-and-forget / shutdown waits: - InboundAPI-018: AuditWriteMiddleware observes faulted audit-write tasks via OnlyOnFaulted continuation (Warning log; response unchanged). - SnF-024: StoreAndForwardService.StopAsync awaits in-flight retry sweep with a bounded SweepShutdownWaitTimeout (10s). Leak / refactor: - Comm-021: SiteStreamGrpcServer.SubscribeInstance wraps Subscribe in its own try/catch so a throw doesn't leak the relay actor or _activeStreams entry. - Comm-022: VERIFIED already-closed by Comm-016's dead-code purge. - CLI-017: BundleCommands' three subcommands delegate to ExecuteCommandAsync (auth-failure exit-code contract unified). Defensive / validation: - CLI-021: CliConfig.Load wraps file-read/JSON parse so malformed config prints a warning and returns defaults instead of crashing the CLI. - Host-022: ParseLevel emits stderr one-shot warning for unrecognised MinimumLevel instead of silently coercing to Information. - ESG-019: ExternalSystemClient sets HttpClient.Timeout=Infinite so the per-call CTS is the sole timeout source (was clipped to 100s by .NET). - Security-020: New SecurityOptionsValidator (IValidateOptions) rejects empty LdapServer/LdapSearchBase with ValidateOnStart. - DM-019: Lifecycle command timeouts now emit DisableTimedOut/EnableTimedOut/ DeleteTimedOut audit entries (mirrors DeployFailed pattern). Plus reconciled stale per-module Open-findings counters that had drifted from prior sessions. 20+ new regression tests across 11 test projects; build clean; affected suites all green. README regenerated: 75 open (was 93).
112 lines
3.7 KiB
C#
112 lines
3.7 KiB
C#
using Microsoft.Extensions.Configuration;
|
|
using Serilog.Events;
|
|
|
|
namespace ScadaLink.Host.Tests;
|
|
|
|
/// <summary>
|
|
/// Host-011: <c>ScadaLink:Logging:MinimumLevel</c> must actually drive the Serilog
|
|
/// minimum level. Previously the value was bound into <see cref="LoggingOptions"/>
|
|
/// but never read, so editing it had no effect.
|
|
/// </summary>
|
|
public class LoggerConfigurationTests
|
|
{
|
|
private static IConfiguration BuildConfig(string? minimumLevel)
|
|
{
|
|
var values = new Dictionary<string, string?>();
|
|
if (minimumLevel != null)
|
|
values["ScadaLink:Logging:MinimumLevel"] = minimumLevel;
|
|
return new ConfigurationBuilder().AddInMemoryCollection(values).Build();
|
|
}
|
|
|
|
[Fact]
|
|
public void MinimumLevel_Warning_SuppressesInformationLogs()
|
|
{
|
|
var sink = new InMemorySink();
|
|
var logger = LoggerConfigurationFactory
|
|
.Build(BuildConfig("Warning"), "Central", "central", "node1")
|
|
.WriteTo.Sink(sink)
|
|
.CreateLogger();
|
|
|
|
logger.Information("info message");
|
|
logger.Warning("warning message");
|
|
|
|
Assert.Single(sink.LogEvents);
|
|
Assert.Equal(LogEventLevel.Warning, sink.LogEvents[0].Level);
|
|
}
|
|
|
|
[Fact]
|
|
public void MinimumLevel_Debug_AllowsDebugLogs()
|
|
{
|
|
var sink = new InMemorySink();
|
|
var logger = LoggerConfigurationFactory
|
|
.Build(BuildConfig("Debug"), "Site", "site-a", "node1")
|
|
.WriteTo.Sink(sink)
|
|
.CreateLogger();
|
|
|
|
logger.Debug("debug message");
|
|
|
|
Assert.Single(sink.LogEvents);
|
|
Assert.Equal(LogEventLevel.Debug, sink.LogEvents[0].Level);
|
|
}
|
|
|
|
[Fact]
|
|
public void MinimumLevel_Absent_DefaultsToInformation()
|
|
{
|
|
var sink = new InMemorySink();
|
|
var logger = LoggerConfigurationFactory
|
|
.Build(BuildConfig(null), "Central", "central", "node1")
|
|
.WriteTo.Sink(sink)
|
|
.CreateLogger();
|
|
|
|
logger.Debug("debug message");
|
|
logger.Information("info message");
|
|
|
|
Assert.Single(sink.LogEvents);
|
|
Assert.Equal(LogEventLevel.Information, sink.LogEvents[0].Level);
|
|
}
|
|
|
|
/// <summary>
|
|
/// Host-022: an unrecognised <c>ScadaLink:Logging:MinimumLevel</c> (e.g. a typo
|
|
/// like "Informaiton") must NOT abort startup but MUST emit a one-shot warning
|
|
/// naming the offending value and the fallback so the silent coercion is
|
|
/// visible. Null/blank is treated as "unset" and silently defaults.
|
|
/// </summary>
|
|
[Fact]
|
|
public void ParseLevel_UnrecognisedValue_FallsBackAndWarns()
|
|
{
|
|
var writer = new StringWriter();
|
|
|
|
var result = LoggerConfigurationFactory.ParseLevel("Informaiton", writer);
|
|
|
|
Assert.Equal(LogEventLevel.Information, result);
|
|
var warning = writer.ToString();
|
|
Assert.Contains("warning", warning, StringComparison.OrdinalIgnoreCase);
|
|
Assert.Contains("Informaiton", warning);
|
|
Assert.Contains("Information", warning);
|
|
}
|
|
|
|
[Fact]
|
|
public void ParseLevel_NullOrBlank_FallsBackSilently()
|
|
{
|
|
var writer = new StringWriter();
|
|
|
|
var nullResult = LoggerConfigurationFactory.ParseLevel(null, writer);
|
|
var blankResult = LoggerConfigurationFactory.ParseLevel(" ", writer);
|
|
|
|
Assert.Equal(LogEventLevel.Information, nullResult);
|
|
Assert.Equal(LogEventLevel.Information, blankResult);
|
|
Assert.Empty(writer.ToString());
|
|
}
|
|
|
|
[Fact]
|
|
public void ParseLevel_RecognisedValue_NoWarning()
|
|
{
|
|
var writer = new StringWriter();
|
|
|
|
var result = LoggerConfigurationFactory.ParseLevel("Warning", writer);
|
|
|
|
Assert.Equal(LogEventLevel.Warning, result);
|
|
Assert.Empty(writer.ToString());
|
|
}
|
|
}
|