dohertj2 dohertj2
  • Joined on 2026-02-20
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-18 23:10:11 -04:00
e33783e042 Merge pull request 'Phase 3 PR 56 -- Siemens S7-1500 pymodbus profile + smoke' (#55) from phase-3-pr56-s7-sim-profile into v2
10c724b5b6 Phase 3 PR 56 -- Siemens S7-1500 pymodbus profile + smoke integration test. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/s7_1500.json modelling the SIMATIC S7-1500 + MB_SERVER default deployment documented in docs/v2/s7.md: DB1.DBW0 = 0xABCD fingerprint marker (operators reserve this so clients can verify they're talking to the right DB), scratch HR range 200..209 for write-roundtrip tests mirroring dl205.json + standard.json, Float32 1.5f at HR[100..101] in ABCD word order (high word first -- OPPOSITE of DL260 CDAB), Int32 0x12345678 at HR[300..301] in ABCD. Also seeds a coil at bit-addr 400 (= cell 25 bit 0) and a discrete input at bit-addr 500 (= cell 31 bit 0) so future S7-specific tests for FC01/FC02 have stable markers. shared blocks=true to match the proven dl205.json pattern (pymodbus's bits/uint16 cells coexist cleanly when addresses don't collide). Write list references cells (0, 25, 100-101, 200-209, 300-301), not bit addresses -- pymodbus's write-range entries are cell-indexed, not bit-indexed. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/S7/ directory with S7_1500Profile.cs (mirrors DL205Profile pattern: SmokeHoldingRegister=200, SmokeHoldingValue=4321, BuildOptions tags + probe-disabled + 2s timeout) and S7_1500SmokeTests.cs (single fact S7_1500_roundtrip_write_then_read_of_holding_register that writes SmokeHoldingValue then reads it back, asserting both write status 0 and read status 0 + value equality). Gates on MODBUS_SIM_PROFILE=s7_1500 so the test skips cleanly against other profiles. csproj updated to copy S7/** to test output as PreserveNewest (pattern matching DL205/**). Pymodbus/serve.ps1 ValidateSet extended from {standard,dl205} to {standard,dl205,s7_1500,mitsubishi} -- mitsubishi.json lands in PR 58 but the validator slot is claimed now so the serve.ps1 diff is one line in this PR and zero lines in future PRs. Verified end-to-end: smoke test 1/1 passes against the running pymodbus s7_1500 profile (localhost:5020 FC06 write of 4321 at HR[200] + FC03 read back). 143/143 Modbus.Tests pass, no regression in driver code because this PR is purely test-asset. Per-quirk S7 integration tests (ABCD word order default, FC23 IllegalFunction, MB_SERVER STATUS 0x8383 behaviour, port-per-connection semantics) land in PR 57+.
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#55 2026-04-18 23:10:09 -04:00
Phase 3 PR 56 -- Siemens S7-1500 pymodbus profile + smoke
dohertj2 created pull request dohertj2/lmxopcua#55 2026-04-18 23:10:05 -04:00
Phase 3 PR 56 -- Siemens S7-1500 pymodbus profile + smoke
dohertj2 created branch phase-3-pr60-mitsubishi-quirk-tests in dohertj2/lmxopcua 2026-04-18 23:08:54 -04:00
dohertj2 pushed to phase-3-pr60-mitsubishi-quirk-tests at dohertj2/lmxopcua 2026-04-18 23:08:54 -04:00
a44fc7a610 Phase 3 PR 60 -- Mitsubishi MELSEC quirk integration tests against mitsubishi pymodbus profile. Seven facts in MitsubishiQuirkTests covering the quirks documented in docs/v2/mitsubishi.md that are testable end-to-end via pymodbus: (1) Mitsubishi_D0_fingerprint_reads_0x1234 -- MELSEC operators reserve D0 as a fingerprint word so Modbus clients can verify they're hitting the right Device Assignment block; test reads HR[0]=0x1234 via DRegisterToHolding('D0') helper. (2) Mitsubishi_Float32_CDAB_decodes_1_5f_from_D100 -- reads HR[100..101] with WordSwap AND BigEndian; asserts WordSwap==1.5f AND BigEndian!=1.5f, proving (a) MELSEC uses CDAB default same as DL260, (b) opposite of S7 ABCD, (c) driver flag is not a no-op. (3) Mitsubishi_D10_is_binary_not_BCD -- reads HR[10]=0x04D2 as Int16 and asserts value 1234 (binary decode), contrasting with DL205's BCD-by-default convention. (4) Mitsubishi_D10_as_BCD_throws_because_nibble_is_non_decimal -- reads same HR[10] as Bcd16 and asserts StatusCode != 0 because nibble 0xD fails BCD validation; proves the BCD decoder fails loud when the tag config is wrong rather than silently returning garbage. (5) Mitsubishi_QLiQR_X210_hex_maps_to_DI_528_reads_ON -- reads FC02 at the MelsecAddress.XInputToDiscrete('X210', Q_L_iQR)-resolved address (=528 decimal) and asserts ON; proves the hex-parsing path end-to-end. (6) Mitsubishi_family_trap_X20_differs_on_Q_vs_FX -- unit-level proof in the integration file so the headline family trap is visible to anyone filtering by Device=Mitsubishi. (7) Mitsubishi_M512_maps_to_coil_512_reads_ON -- reads FC01 at MRelayToCoil('M512')=512 (decimal) and asserts ON; proves the decimal M-relay path. Test fixture pattern: single MitsubishiQuirkTests class with a shared ShouldRun + NewDriverAsync helper rather than per-quirk classes (contrast with DL205's per-quirk splits). MELSEC per-model differentiation is handled by MelsecFamily enum on the helper rather than per-PR -- so one quirk file + one family enum covers Q/L/iQ-R/FX/iQ-F, and a new PLC family just adds an enum case instead of a new test class. 8/8 Mitsubishi integration tests pass (1 smoke + 7 quirk). 176/176 Modbus.Tests unit suite still green. S7 + DL205 integration tests can be run against their respective profiles by swapping MODBUS_SIM_PROFILE and restarting the pymodbus sim -- each family gates on its profile env var so no cross-family test pollution.
dohertj2 created branch phase-3-pr59-melsec-address-helper in dohertj2/lmxopcua 2026-04-18 23:08:50 -04:00
dohertj2 pushed to phase-3-pr59-melsec-address-helper at dohertj2/lmxopcua 2026-04-18 23:08:50 -04:00
d4c1873998 Phase 3 PR 59 -- MelsecAddress helper for MELSEC X/Y hex-vs-octal family trap + D/M bank bases. Adds MelsecAddress static class with XInputToDiscrete, YOutputToCoil, MRelayToCoil, DRegisterToHolding helpers and a MelsecFamily enum {Q_L_iQR, F_iQF} that drives whether X/Y addresses are parsed as hex (Q-series convention) or octal (FX-series convention). This is the #1 MELSEC driver bug source per docs/v2/mitsubishi.md: the string 'X20' on a MELSEC-Q means DI 32 (hex 0x20) while the same string on an FX3U means DI 16 (octal 0o20). The helper forces the caller to name the family explicitly; no 'sensible default' because wrong defaults just move the bug. Key design decisions: (1) Family is an enum argument, not a helper-level static-selector, because real deployments have BOTH Q-series and FX-series PLCs on the same gateway -- one driver instance per device means family must be per-tag, not per-driver. (2) Bank base is a ushort argument defaulting to 0. Real QJ71MT91/LJ71MT91 assignment blocks commonly place X at DI 8192+, Y at coil 8192+, etc. to leave the low-address range for D-registers; the helper takes the site's configured base as runtime config rather than a compile-time constant. Matches the 'driver opt-in per tag' pattern DirectLogicAddress established for DL260. (3) M-relay and D-register are DECIMAL on every MELSEC family -- docs explicitly; the MELSEC confusion is only about X/Y, not about data registers or internal relays. Helpers reject non-numeric M/D addresses and honor bank bases the same way. (4) Parser walks digits manually for both hex and octal (instead of int.Parse with NumberStyles) so non-hex / non-octal characters give a clear ArgumentException with the offending char + family name. Prevents a subtle class of bugs where int.Parse('X20', Hex) silently returns 32 even for F_iQF callers. Unit tests (MelsecAddressTests, 34 facts): XInputToDiscrete_QLiQR_parses_hex theory (X0, X9, XA, XF, X10, X20, X1FF + lowercase); XInputToDiscrete_FiQF_parses_octal theory (X0, X7, X10, X20, X777); YOutputToCoil equivalents; Same_address_string_decodes_differently_between_families (the headline trap, X20 => 32 on Q vs 16 on FX); reject-non-octal / reject-non-hex / reject-empty / overflow facts; honors-bank-base for X and M and D. 176/176 Modbus.Tests pass (143 prior + 34 new Melsec). No driver core changes -- this is purely a new helper class in the Driver.Modbus project. PR 60 wires it into integration tests against the mitsubishi pymodbus profile.
dohertj2 created branch phase-3-pr58-mitsubishi-sim-profile in dohertj2/lmxopcua 2026-04-18 23:08:49 -04:00
dohertj2 pushed to phase-3-pr58-mitsubishi-sim-profile at dohertj2/lmxopcua 2026-04-18 23:08:49 -04:00
f52b7d8979 Phase 3 PR 58 -- Mitsubishi MELSEC pymodbus profile + smoke integration test. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/mitsubishi.json modelling a representative MELSEC Modbus Device Assignment block: D0..D1023 -> HR[0..1023], M-relay marker at coil 512 (cell 32) and X-input marker at DI 528 (cell 33). Covers the canonical MELSEC quirks from docs/v2/mitsubishi.md: D0 fingerprint at HR[0]=0x1234 so clients can verify the assignment parameter block is in effect, scratch HR 200..209 mirroring dl205/s7_1500/standard scratch range for uniform smoke tests, Float32 1.5f at HR[100..101] in CDAB word order (HR[100]=0, HR[101]=0x3FC0) -- same as DL260, OPPOSITE of S7 ABCD, confirms MELSEC-family driver profile default must be ByteOrder.WordSwap. Int32 0x12345678 CDAB at HR[300..301]. D10 = binary 1234 (0x04D2) proves MELSEC is BINARY-by-default (opposite of DL205 BCD-by-default quirk) -- reading D10 with Bcd16 data type would throw InvalidDataException on nibble 0xD. M-relay marker cell moved to address 32 (coil 512) to avoid shared-block collision with D0 uint16 marker at cell 0; pymodbus shared-blocks=true semantics allow only one type per cell index, so Modbus-coil-0 can't coexist with Modbus-HR-0 on the same sim. Same pattern we applied to dl205 profile (X-input bank at cell 1, not cell 0, to coexist with V0 marker). Adds Mitsubishi/ test directory with MitsubishiProfile.cs (SmokeHoldingRegister=200, SmokeHoldingValue=7890, BuildOptions with probe-disabled + 2s timeout) and MitsubishiSmokeTests.cs (Mitsubishi_roundtrip_write_then_read_of_holding_register single fact that writes 7890 at HR[200] then reads back, gated on MODBUS_SIM_PROFILE=mitsubishi). csproj copies Mitsubishi/** as PreserveNewest. Per-model differences (FX5U firmware gate, QJ71MT91 FC22/23 absence, FX/iQ-F octal vs Q/L/iQ-R hex X-addressing) are handled in the MelsecAddress helper (PR 59) + per-model test classes (PR 60). Verified: smoke 1/1 passes against live mitsubishi sim. Prior S7 tests 4/4 still green when swapped back. Modbus.Tests unit suite 143/143.
dohertj2 created branch phase-3-pr57-s7-quirk-tests in dohertj2/lmxopcua 2026-04-18 23:08:46 -04:00
dohertj2 pushed to phase-3-pr57-s7-quirk-tests at dohertj2/lmxopcua 2026-04-18 23:08:46 -04:00
b54724a812 Phase 3 PR 57 -- S7 byte-order + fingerprint integration tests against s7_1500 pymodbus profile. Three facts in new S7_ByteOrderTests class: (1) S7_Float32_ABCD_decodes_1_5f_from_HR100 reads HR[100..101] with ModbusByteOrder.BigEndian AND with WordSwap on the same wire bytes; asserts BigEndian==1.5f AND WordSwap!=1.5f -- proving both that Siemens S7 stores Float32 in ABCD word order (opposite of DL260 CDAB) and that the ByteOrder flag is not a no-op on the same wire buffer. (2) S7_Int32_ABCD_decodes_0x12345678_from_HR300 reads HR[300]=0x1234 + HR[301]=0x5678 with BigEndian and asserts the reassembled Int32 = 0x12345678; documents the contrast with DL260 CDAB Int32 encoding. (3) S7_DB1_fingerprint_marker_at_HR0_reads_0xABCD reads HR[0]=0xABCD -- real MB_SERVER deployments reserve DB1.DBW0 as a fingerprint so clients can verify they're pointing at the right DB, protecting against typos in the MB_SERVER.MB_HOLD_REG.DB_number parameter. No driver code changes -- the ByteOrder.BigEndian path has existed since PR 24; this PR exists to lock in the S7-specific semantics at the integration level so future refactors of NormalizeWordOrder can't silently break S7. All 3 tests gate on MODBUS_SIM_PROFILE=s7_1500 so they skip cleanly against dl205 or standard profiles. Verified end-to-end: 4/4 S7 integration tests pass (1 smoke from PR 56 + 3 new). No regression in driver unit tests. Per the per-quirk-PR plan: the S7 quirks NOT testable via pymodbus sim (MB_SERVER STATUS 0x8383 optimized-DB behavior, port-per-connection semantics, CP 343-1 Lean license rejection, STOP-mode non-determinism) remain in docs/v2/s7.md as design guidance for driver users rather than automated tests -- they're TIA-Portal-side or CP-hardware-side behaviors that pymodbus cannot reproduce without custom Python actions.
dohertj2 created branch phase-3-pr56-s7-sim-profile in dohertj2/lmxopcua 2026-04-18 23:08:44 -04:00
dohertj2 pushed to phase-3-pr56-s7-sim-profile at dohertj2/lmxopcua 2026-04-18 23:08:44 -04:00
10c724b5b6 Phase 3 PR 56 -- Siemens S7-1500 pymodbus profile + smoke integration test. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/Pymodbus/s7_1500.json modelling the SIMATIC S7-1500 + MB_SERVER default deployment documented in docs/v2/s7.md: DB1.DBW0 = 0xABCD fingerprint marker (operators reserve this so clients can verify they're talking to the right DB), scratch HR range 200..209 for write-roundtrip tests mirroring dl205.json + standard.json, Float32 1.5f at HR[100..101] in ABCD word order (high word first -- OPPOSITE of DL260 CDAB), Int32 0x12345678 at HR[300..301] in ABCD. Also seeds a coil at bit-addr 400 (= cell 25 bit 0) and a discrete input at bit-addr 500 (= cell 31 bit 0) so future S7-specific tests for FC01/FC02 have stable markers. shared blocks=true to match the proven dl205.json pattern (pymodbus's bits/uint16 cells coexist cleanly when addresses don't collide). Write list references cells (0, 25, 100-101, 200-209, 300-301), not bit addresses -- pymodbus's write-range entries are cell-indexed, not bit-indexed. Adds tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests/S7/ directory with S7_1500Profile.cs (mirrors DL205Profile pattern: SmokeHoldingRegister=200, SmokeHoldingValue=4321, BuildOptions tags + probe-disabled + 2s timeout) and S7_1500SmokeTests.cs (single fact S7_1500_roundtrip_write_then_read_of_holding_register that writes SmokeHoldingValue then reads it back, asserting both write status 0 and read status 0 + value equality). Gates on MODBUS_SIM_PROFILE=s7_1500 so the test skips cleanly against other profiles. csproj updated to copy S7/** to test output as PreserveNewest (pattern matching DL205/**). Pymodbus/serve.ps1 ValidateSet extended from {standard,dl205} to {standard,dl205,s7_1500,mitsubishi} -- mitsubishi.json lands in PR 58 but the validator slot is claimed now so the serve.ps1 diff is one line in this PR and zero lines in future PRs. Verified end-to-end: smoke test 1/1 passes against the running pymodbus s7_1500 profile (localhost:5020 FC06 write of 4321 at HR[200] + FC03 read back). 143/143 Modbus.Tests pass, no regression in driver code because this PR is purely test-asset. Per-quirk S7 integration tests (ABCD word order default, FC23 IllegalFunction, MB_SERVER STATUS 0x8383 behaviour, port-per-connection semantics) land in PR 57+.
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-18 22:54:11 -04:00
8c89d603e8 Merge pull request 'Phase 3 PR 55 -- Mitsubishi MELSEC Modbus TCP quirks research doc' (#54) from phase-3-pr55-mitsubishi-research-doc into v2
c506ea298a Phase 3 PR 55 -- Mitsubishi MELSEC Modbus TCP quirks research document. 451-line doc at docs/v2/mitsubishi.md mirroring the docs/v2/dl205.md template for the MELSEC family (Q-series + QJ71MT91, L-series + LJ71MT91, iQ-R + RJ71EN71, iQ-R built-in Ethernet, iQ-F FX5U built-in, FX3U + FX3U-ENET / FX3U-ENET-P502, FX3GE built-in). Like Siemens S7, MELSEC Modbus is a patchwork of per-site-configured add-on modules rather than a fixed firmware stack, but the MELSEC-specific traps are different enough to warrant their own document. Key findings worth flagging for the PR 58+ implementation track: (1) MODULE NAMING TRAP -- QJ71MB91 is SERIAL RTU, not TCP. The Q-series TCP module is QJ71MT91. Driver docs + config UI should surface this clearly because the confusion costs operators hours when they try to connect to an RS-232 module via Ethernet. (2) NO CANONICAL MAPPING -- every MELSEC Modbus site has a unique 'Modbus Device Assignment Parameter' block of up to 16 assignments (each binding a MELSEC device range like D0..D1023 to a Modbus-address range); the driver must treat the mapping as runtime config, not device-family profile. (3) X/Y BASE DEPENDS ON FAMILY -- Q/L/iQ-R use HEX notation for X/Y (X20 = decimal 32), FX/iQ-F use OCTAL (X20 = decimal 16, same as DL260); iQ-F has a GX Works3 project toggle that can flip this. Single biggest off-by-N source in MELSEC driver code -- driver address helper must take a family selector. (4) Word order CDAB across Q/L/iQ-R/iQ-F by default (CPU-level, not module-level) -- no user-configurable swap on the server side. FX5U's SWAP instruction is for CLIENT mode only. Driver Mitsubishi profile default must be ByteOrder.WordSwap, matching DL260 but OPPOSITE of Siemens S7. (5) D-registers are BINARY by default (opposite of DL205's BCD-by-default). FNC 18 BCD / FNC 19 BIN instructions confirm binary-by-default in the ladder. Caller must explicitly opt-in to Bcd16/Bcd32 tags when the ladder stores BCD, same pattern as DL205 but the default is inverted. (6) FX5U FIRMWARE GATE -- needs firmware >= 1.060 for native Modbus TCP server; older firmware is client-only. Surface a clear capability error on connect. (7) FX3U PORT 502 SPLIT -- the standard FX3U-ENET cannot bind port 502 (lower port range restricted on the firmware); only FX3U-ENET-P502 can. FX3U-ENET-ADP has no Modbus at all and is a common operator mis-purchase -- driver should surface 'module does not support Modbus' as a distinct error, not 'connection refused'. (8) QJ71MT91 does NOT support FC22 (Mask Write) or FC23 (Read-Write Multiple). iQ-R and iQ-F do. Driver bulk-read optimization must gate on module capability. (9) MAX CONNECTIONS -- 16 simultaneous on Q/L/iQ-R, 8 on FX5U and FX3U-ENET. (10) STOP-mode writes -- configurable on Q/L/iQ-R/iQ-F (default = accept writes even in STOP), always rejected with exception 04 on FX3U-ENET. Per-model test differentiation section names the tests Mitsubishi_QJ71MT91_*, Mitsubishi_FX5U_*, Mitsubishi_FX3U_ENET_*, with a shared Mitsubishi_Common_* fixture for CDAB-word-order + binary-not-BCD + standard-exception-codes tests. 17 cited references including primary Mitsubishi manuals (SH-080446 for QJ71MT91, JY997D56101 for FX5, SH-081259 for iQ-R Ethernet, JY997D18101 for FX3U-ENET) plus Ignition / Kepware / Fernhill / HMS third-party driver release notes. Three unconfirmed rumours flagged explicitly: iQ-R RJ71EN71 early firmware rumoured ABCD word order (no primary source), QJ71MT91 firmware < 2010-05 FC15 odd-byte-count truncation (forum report only), FX3U-ENET firmware < 1.14 out-of-order TxId echoes under load (unreproducible on bench). Pure documentation PR -- no code, no tests. Per-quirk implementation lands in PRs 58+. Research conducted 2026-04-18.
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#54 2026-04-18 22:54:10 -04:00
Phase 3 PR 55 -- Mitsubishi MELSEC Modbus TCP quirks research doc
dohertj2 created pull request dohertj2/lmxopcua#54 2026-04-18 22:54:06 -04:00
Phase 3 PR 55 -- Mitsubishi MELSEC Modbus TCP quirks research doc
dohertj2 merged pull request dohertj2/lmxopcua#53 2026-04-18 22:54:03 -04:00
Phase 3 PR 54 -- Siemens S7 Modbus TCP quirks research doc
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-18 22:54:03 -04:00
299bd4a932 Merge pull request 'Phase 3 PR 54 -- Siemens S7 Modbus TCP quirks research doc' (#53) from phase-3-pr54-s7-research-doc into v2
9e2b5b330f Phase 3 PR 54 -- Siemens S7 Modbus TCP quirks research document. 485-line doc at docs/v2/s7.md mirroring the docs/v2/dl205.md template for the Siemens SIMATIC S7 family (S7-1200 / S7-1500 / S7-300 / S7-400 / ET 200SP / CP 343-1 / CP 443-1 / CP 343-1 Lean / MODBUSPN). Siemens S7 is fundamentally different from DL260: there is no fixed Modbus memory map baked into firmware -- every deployment runs MB_SERVER (S7-1200/1500/ET 200SP), MODBUSCP (S7-300/400 + CP), or MODBUSPN (S7-300/400 PN) library blocks wired up to user DBs via the MB_HOLD_REG / ADDR parameters. The driver's job is therefore to handle per-site CONFIG rather than per-family QUIRKS, and the doc makes that explicit. Key findings worth flagging for the PR 56+ implementation track: (1) S7 has no fixed memory map -- must accept per-site DriverConfig, cannot assume vendor-standard layout. (2) MB_SERVER requires NON-optimized DBs in TIA Portal; optimized DBs cause the library to return STATUS 0x8383 on every access -- the single most common S7 Modbus deployment bug in the field. (3) Word order is ABCD by default (big-endian bytes + big-endian words) across all Siemens S7 Modbus paths, which is the OPPOSITE of DL260 CDAB -- the Modbus driver's S7 profile default must be ByteOrder.BigEndian, not WordSwap. (4) MB_SERVER listens on ONE port per FB instance; multi-client support requires running MB_SERVER on 502 / 503 / 504 / ... simultaneously -- most clients assume port 502 multiplexes, which is wrong on S7. (5) CP 343-1 Lean is SERVER-ONLY and requires the separate 2XV9450-1MB00 MODBUS TCP CP library license; client mode calls return immediate error on Lean. (6) MB_SERVER does NOT filter Unit ID, accepts any value. Means the driver can't use Unit ID to detect 'direct vs gateway' topology. (7) FC23 Read-Write Multiple, FC22 Mask Write, FC20/21 File Records, FC43 Device Identification all return exception 01 Illegal Function on every S7 variant -- the driver MUST NOT attempt bulk-read optimisation via FC23 when talking to S7. (8) STOP-mode read/write behaviour is non-deterministic across firmware bands: reads may return cached data (library internal buffer), writes may succeed-silently or return exception 04 depending on CPU firmware version -- flagged as 'driver treats both as unavailable, do not distinguish'. Unconfirmed rumours flagged separately: 'V2.0+ reverses float byte order' claim (cited but not reproduced), STOP-mode caching location (folklore, no primary source). Per-model test differentiation section names the tests as S7_<model>_<behavior> matching the DL205 template convention (e.g. S7_1200_MB_SERVER_requires_non_optimized_DB, S7_343_1_Lean_rejects_client_mode, S7_FC23_returns_IllegalFunction). 31 cited references across the Siemens Industry Online Support entry-ID system (68011496 for MB_SERVER FAQ, etc.), TIA Portal library manuals, and three third-party driver vendor release notes (Kepware, Ignition, FactoryTalk). This is a pure documentation PR -- no code, no tests, no csproj changes. Per-quirk implementation lands in PRs 56+. Research conducted 2026-04-18 against latest publicly-available Siemens documentation; STOP-mode behaviour and MB_SERVER versioning specifically cross-checked against Siemens forum answers from 2024-2025.
Compare 2 commits »
dohertj2 created pull request dohertj2/lmxopcua#53 2026-04-18 22:53:59 -04:00
Phase 3 PR 54 -- Siemens S7 Modbus TCP quirks research doc
dohertj2 pushed to phase-3-pr55-mitsubishi-research-doc at dohertj2/lmxopcua 2026-04-18 22:53:08 -04:00
c506ea298a Phase 3 PR 55 -- Mitsubishi MELSEC Modbus TCP quirks research document. 451-line doc at docs/v2/mitsubishi.md mirroring the docs/v2/dl205.md template for the MELSEC family (Q-series + QJ71MT91, L-series + LJ71MT91, iQ-R + RJ71EN71, iQ-R built-in Ethernet, iQ-F FX5U built-in, FX3U + FX3U-ENET / FX3U-ENET-P502, FX3GE built-in). Like Siemens S7, MELSEC Modbus is a patchwork of per-site-configured add-on modules rather than a fixed firmware stack, but the MELSEC-specific traps are different enough to warrant their own document. Key findings worth flagging for the PR 58+ implementation track: (1) MODULE NAMING TRAP -- QJ71MB91 is SERIAL RTU, not TCP. The Q-series TCP module is QJ71MT91. Driver docs + config UI should surface this clearly because the confusion costs operators hours when they try to connect to an RS-232 module via Ethernet. (2) NO CANONICAL MAPPING -- every MELSEC Modbus site has a unique 'Modbus Device Assignment Parameter' block of up to 16 assignments (each binding a MELSEC device range like D0..D1023 to a Modbus-address range); the driver must treat the mapping as runtime config, not device-family profile. (3) X/Y BASE DEPENDS ON FAMILY -- Q/L/iQ-R use HEX notation for X/Y (X20 = decimal 32), FX/iQ-F use OCTAL (X20 = decimal 16, same as DL260); iQ-F has a GX Works3 project toggle that can flip this. Single biggest off-by-N source in MELSEC driver code -- driver address helper must take a family selector. (4) Word order CDAB across Q/L/iQ-R/iQ-F by default (CPU-level, not module-level) -- no user-configurable swap on the server side. FX5U's SWAP instruction is for CLIENT mode only. Driver Mitsubishi profile default must be ByteOrder.WordSwap, matching DL260 but OPPOSITE of Siemens S7. (5) D-registers are BINARY by default (opposite of DL205's BCD-by-default). FNC 18 BCD / FNC 19 BIN instructions confirm binary-by-default in the ladder. Caller must explicitly opt-in to Bcd16/Bcd32 tags when the ladder stores BCD, same pattern as DL205 but the default is inverted. (6) FX5U FIRMWARE GATE -- needs firmware >= 1.060 for native Modbus TCP server; older firmware is client-only. Surface a clear capability error on connect. (7) FX3U PORT 502 SPLIT -- the standard FX3U-ENET cannot bind port 502 (lower port range restricted on the firmware); only FX3U-ENET-P502 can. FX3U-ENET-ADP has no Modbus at all and is a common operator mis-purchase -- driver should surface 'module does not support Modbus' as a distinct error, not 'connection refused'. (8) QJ71MT91 does NOT support FC22 (Mask Write) or FC23 (Read-Write Multiple). iQ-R and iQ-F do. Driver bulk-read optimization must gate on module capability. (9) MAX CONNECTIONS -- 16 simultaneous on Q/L/iQ-R, 8 on FX5U and FX3U-ENET. (10) STOP-mode writes -- configurable on Q/L/iQ-R/iQ-F (default = accept writes even in STOP), always rejected with exception 04 on FX3U-ENET. Per-model test differentiation section names the tests Mitsubishi_QJ71MT91_*, Mitsubishi_FX5U_*, Mitsubishi_FX3U_ENET_*, with a shared Mitsubishi_Common_* fixture for CDAB-word-order + binary-not-BCD + standard-exception-codes tests. 17 cited references including primary Mitsubishi manuals (SH-080446 for QJ71MT91, JY997D56101 for FX5, SH-081259 for iQ-R Ethernet, JY997D18101 for FX3U-ENET) plus Ignition / Kepware / Fernhill / HMS third-party driver release notes. Three unconfirmed rumours flagged explicitly: iQ-R RJ71EN71 early firmware rumoured ABCD word order (no primary source), QJ71MT91 firmware < 2010-05 FC15 odd-byte-count truncation (forum report only), FX3U-ENET firmware < 1.14 out-of-order TxId echoes under load (unreproducible on bench). Pure documentation PR -- no code, no tests. Per-quirk implementation lands in PRs 58+. Research conducted 2026-04-18.