554b05d28c
Reviewed the new SignalR dashboard and fixed its two top findings: a stored XSS on the connection-detail page (unescaped tag name / direction / timestamp rendered into innerHTML) and FC03/FC04 cache hits bypassing the debug-view capture, which left cached tags frozen while their age climbed. Also adds an optional human-friendly Name to BCD tags surfaced on the debug view, and loads the real fleet config from tags.txt (12 named BCD tags, PLC Z28061) so the published appsettings.json is deploy-ready. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
248 lines
14 KiB
JSON
248 lines
14 KiB
JSON
// mbproxy configuration template — copy to %ProgramData%\mbproxy\appsettings.json
|
||
// and edit before starting the service.
|
||
//
|
||
// The .NET configuration loader accepts // and /* */ comments in JSON files
|
||
// (JSONC semantics) when using the default Host.CreateApplicationBuilder path.
|
||
//
|
||
// IMPORTANT: This file is overwritten on each install ONLY if no appsettings.json
|
||
// already exists at the destination. An existing file is always preserved.
|
||
{
|
||
"Mbproxy": {
|
||
|
||
// ── Global BCD tag list ─────────────────────────────────────────────────────────────
|
||
// These tags apply to EVERY PLC by default.
|
||
// Each entry: Address (Modbus PDU address, decimal), Width (16 or 32 bits).
|
||
//
|
||
// Width 16 — one register holds 4 BCD digits (0–9999).
|
||
// Wire value 0x1234 decodes to decimal 1234.
|
||
//
|
||
// Width 32 — a CDAB-ordered register pair (Address = low word, Address+1 = high word).
|
||
// Decoded decimal = high * 10000 + low (DirectLOGIC CDAB word order).
|
||
//
|
||
// Per-PLC overrides (see Plcs[].BcdTags below):
|
||
// Add — appends extra tags beyond what Global defines, or overrides a
|
||
// Global entry's Width when the same Address appears in both.
|
||
// Remove — removes specific addresses from the effective set for that PLC.
|
||
// Effective set = (Global ∪ Add) − Remove, resolved per PDU.
|
||
"BcdTags": {
|
||
// Fleet-wide BCD tag list from tags.txt — applies to every PLC.
|
||
// Address = Modbus PDU-decimal = (4xxxx Modbus address − 40001), which also
|
||
// equals the DirectLOGIC V-memory address converted octal → decimal
|
||
// (e.g. 41549 / V3014 → 41549 − 40001 = 1548 ; octal 3014 = 1548).
|
||
// A 32-bit tag is ONE entry at its low/base address; it covers Address &
|
||
// Address+1 (CDAB: low word at Address, high word at Address+1).
|
||
// Name (optional) is a human-friendly label shown on the connection-detail
|
||
// debug view; it has no effect on rewriting. tags.txt's "Data Direction" is
|
||
// informational — the proxy rewrites BCD on whichever FC touches the address.
|
||
// CacheTtlMs (optional, per entry) opts a tag into the Phase-11 response cache;
|
||
// omitted / 0 = uncached (the default for every tag).
|
||
"Global": [
|
||
// ── 16-bit setpoints — BCD16, HMI-written ────────────────────────────
|
||
{ "Address": 1536, "Width": 16, "Name": "Left ArgonSP" }, // 41537
|
||
{ "Address": 1539, "Width": 16, "Name": "Right ArgonSP" }, // 41540
|
||
{ "Address": 1544, "Width": 16, "Name": "Left ChlorineSP" }, // 41545 · V3010
|
||
{ "Address": 1545, "Width": 16, "Name": "Right ChlorineSP" }, // 41546 · V3011
|
||
{ "Address": 1546, "Width": 16, "Name": "Left HydrogenSP" }, // 41547 · V3012
|
||
{ "Address": 1547, "Width": 16, "Name": "Right HydrogenSP" }, // 41548 · V3013
|
||
{ "Address": 1548, "Width": 16, "Name": "Left AirSP" }, // 41549 · V3014
|
||
{ "Address": 1549, "Width": 16, "Name": "Right AirSP" }, // 41550 · V3015
|
||
|
||
// ── 32-bit runtimes — BCD32, read; CDAB pair spans Address & Address+1 ─
|
||
{ "Address": 4616, "Width": 32, "Name": "MTA Runtime Left (min)" }, // 44617/44618 · V11010
|
||
{ "Address": 4618, "Width": 32, "Name": "MTA Runtime Right (min)" }, // 44619/44620 · V11012
|
||
{ "Address": 4626, "Width": 32, "Name": "FRR Runtime Left (min)" }, // 44627/44628 · V11022
|
||
{ "Address": 4628, "Width": 32, "Name": "FRR Runtime Right (min)" } // 44629/44630 · V11024
|
||
]
|
||
},
|
||
|
||
// ── PLC list ────────────────────────────────────────────────────────────────────────
|
||
// Each entry maps one upstream proxy port → one backend PLC.
|
||
// Upstream clients connect to ListenPort; the proxy forwards to Host:Port.
|
||
//
|
||
// IMPORTANT: H2-ECOM100 modules accept at most 4 simultaneous TCP connections.
|
||
// With the 1:1 upstream↔backend model, a fifth upstream client to the same proxy
|
||
// port will cause a backend connect failure and an immediate upstream disconnect.
|
||
"Plcs": [
|
||
{
|
||
"Name": "Z28061", // Human-readable name (shown on status page and in logs)
|
||
"ListenPort": 5020, // Port the proxy listens on (upstream clients connect here)
|
||
"Host": "10.210.192.5", // PLC IP address or hostname
|
||
"Port": 502 // PLC Modbus TCP port (almost always 502)
|
||
// No BcdTags override — uses the Global set as-is. Per-PLC overrides are
|
||
// available: "BcdTags": { "Add": [ ... ], "Remove": [ ... ] }.
|
||
}
|
||
// Add one entry per PLC. Ports must be unique per host. Typical fleet: 54 PLCs.
|
||
],
|
||
|
||
// ── Admin port ──────────────────────────────────────────────────────────────────────
|
||
// Read-only HTTP status page.
|
||
// GET / → self-contained HTML (auto-refreshes every 5 s)
|
||
// GET /status.json → same data as JSON for monitoring scrapers
|
||
//
|
||
// Authentication is assumed at the network layer (trusted internal segment).
|
||
// Set to 0 to disable the admin endpoint.
|
||
"AdminPort": 8080,
|
||
|
||
// ── Connection timeouts ─────────────────────────────────────────────────────────────
|
||
"Connection": {
|
||
// Max time (ms) to wait for a TCP connect to the PLC backend.
|
||
// Each Polly retry attempt gets its own copy of this timeout.
|
||
"BackendConnectTimeoutMs": 3000,
|
||
|
||
// Max time (ms) to wait for the PLC to respond to a forwarded PDU.
|
||
// Non-idempotent FC06/FC16 writes are one-shot — the upstream client
|
||
// is disconnected immediately on timeout (no retry).
|
||
"BackendRequestTimeoutMs": 3000,
|
||
|
||
// Max time (ms) to wait for in-flight PDUs to complete during graceful shutdown
|
||
// (sc.exe stop / Windows Service stop signal). After this deadline the coordinator
|
||
// cancels remaining work and proceeds. Keep at or below the SCM wait-hint (30 s).
|
||
"GracefulShutdownTimeoutMs": 10000,
|
||
|
||
// ── Keepalive / connection monitoring ───────────────────────────────────
|
||
// The DL205/DL260 ECOM does not emit TCP keepalives, so an idle backend
|
||
// socket can be silently dropped by a middlebox (switch, firewall, NAT)
|
||
// after 2-5 minutes. This section enables OS-level SO_KEEPALIVE on both
|
||
// backend and upstream sockets, and drives a periodic Modbus FC03 heartbeat
|
||
// on each idle backend socket so a dead path is detected before a real
|
||
// client request hits it. See docs/Architecture/Keepalive.md.
|
||
"Keepalive": {
|
||
// Master switch. false → no SO_KEEPALIVE and no heartbeat; the proxy
|
||
// behaves exactly as a pre-keepalive build.
|
||
"Enabled": true,
|
||
|
||
// SO_KEEPALIVE: idle time (ms) before the OS sends its first probe.
|
||
"TcpIdleTimeMs": 30000,
|
||
// SO_KEEPALIVE: interval (ms) between probes once the idle time elapses.
|
||
"TcpProbeIntervalMs": 5000,
|
||
// SO_KEEPALIVE: unanswered probes before the OS declares the socket dead.
|
||
"TcpProbeCount": 4,
|
||
|
||
// Backend heartbeat: after this much backend idle (ms) the proxy issues a
|
||
// synthetic FC03 qty=1 read to keep the path warm and prove the ECOM is
|
||
// still answering Modbus. Must be greater than BackendRequestTimeoutMs.
|
||
"BackendHeartbeatIdleMs": 30000,
|
||
// FC03 PDU address the heartbeat reads. 0 = V0, valid on DL205/DL260.
|
||
"BackendHeartbeatProbeAddress": 0
|
||
}
|
||
},
|
||
|
||
// ── Resilience policies ─────────────────────────────────────────────────────────────
|
||
"Resilience": {
|
||
|
||
// Polly retry policy for backend TCP connect attempts.
|
||
// MaxAttempts: total connect tries (including the first).
|
||
// BackoffMs: delay between each attempt (must have MaxAttempts−1 entries).
|
||
"BackendConnect": {
|
||
"MaxAttempts": 3,
|
||
"BackoffMs": [ 100, 500, 2000 ]
|
||
},
|
||
|
||
// Polly recovery policy for listener bind failures.
|
||
// If a PLC's listen port can't be bound (in-use, bad IP, transient OS error),
|
||
// the supervisor retries according to this schedule.
|
||
// InitialBackoffMs: backoff per step (first N retries).
|
||
// SteadyStateMs: backoff for all subsequent retries (runs indefinitely).
|
||
"ListenerRecovery": {
|
||
"InitialBackoffMs": [ 1000, 2000, 5000, 15000, 30000 ],
|
||
"SteadyStateMs": 30000
|
||
},
|
||
|
||
// Phase 10 — in-flight read coalescing.
|
||
//
|
||
// When two or more upstream clients (HMI / historian / engineering workstation /
|
||
// gateway) issue the SAME FC03 or FC04 read while a matching backend round-trip is
|
||
// already in flight, the proxy attaches the late arrivals to the existing in-flight
|
||
// entry and fans the single PLC response out to every attached client — saving the
|
||
// ECOM's per-scan PDU budget on duplicated reads.
|
||
//
|
||
// Zero post-response staleness: coalescing operates ONLY between "first request
|
||
// sent to PLC" and "response received from PLC" (microseconds to ~10 ms typical).
|
||
// Each upstream client still sees its own MBAP transaction ID echoed correctly;
|
||
// the proxy is transparent.
|
||
//
|
||
// FC06 / FC16 writes are NEVER coalesced (non-idempotent). FC03 vs FC04 are
|
||
// separate Modbus tables and never share a coalescing key. Different unit IDs
|
||
// (multi-drop / gateway-backed setups) never coalesce.
|
||
//
|
||
// Enabled — master switch. Hot-reloadable; flipping to false leaves running
|
||
// coalesced entries to drain naturally.
|
||
// MaxParties — per-entry cap on attached parties. Past the cap, the next
|
||
// identical request opens a fresh backend round-trip (load-shedding
|
||
// safety valve for very fan-out-heavy fleets).
|
||
"ReadCoalescing": {
|
||
"Enabled": true,
|
||
"MaxParties": 32
|
||
}
|
||
},
|
||
|
||
// ── Response cache (Phase 11) — opt-in bounded-staleness cache ──────────────────
|
||
//
|
||
// ⚠ DESIGN-CONTRACT PIVOT: with caching enabled the proxy is no longer purely
|
||
// transparent. Upstream FC03/FC04 reads for cache-enabled tags may return values
|
||
// up to CacheTtlMs MILLISECONDS OLD. Operators opt tags in by setting a non-zero
|
||
// CacheTtlMs on a BcdTagOptions entry (or DefaultCacheTtlMs on a PlcOptions entry).
|
||
//
|
||
// The cache is OFF BY DEFAULT for every tag. A deployment with NO TTL config (this
|
||
// section entirely absent and no BcdTags.*.CacheTtlMs / Plcs[i].DefaultCacheTtlMs)
|
||
// behaves IDENTICALLY to a pre-Phase-11 deployment — no behaviour change.
|
||
//
|
||
// AllowLongTtl — gate for any CacheTtlMs > 60_000. Reload validation
|
||
// rejects configs that exceed 60 s without this opt-in,
|
||
// to prevent accidentally-stale-for-an-hour deployments.
|
||
// MaxEntriesPerPlc — LRU cap per-PLC. Past this cap, the next insert evicts
|
||
// the least-recently-used entry. Defaults to 1000.
|
||
// EvictionIntervalMs — background eviction tick. Scans each PLC's cache and
|
||
// removes entries past their TTL. Defaults to 5000.
|
||
//
|
||
// Properties (full text in docs/Architecture/ResponseCache.md):
|
||
// * Cache hits SHORT-CIRCUIT coalescing entirely (cache → coalesce → backend).
|
||
// * Successful FC06/FC16 write responses invalidate every cached FC03/FC04 entry
|
||
// whose address range OVERLAPS the write — not just exact-key match.
|
||
// * Multi-tag read range: effective TTL = min(TTLs). Any tag with TTL=0 in the
|
||
// range disables caching for the whole read.
|
||
// * Cache stores POST-rewriter bytes; hits never re-invoke the BCD rewriter.
|
||
// * Tag-list hot-reload flushes the affected PLC's whole cache.
|
||
// * No persistence — process restart wipes the cache.
|
||
"Cache": {
|
||
"AllowLongTtl": false,
|
||
"MaxEntriesPerPlc": 1000,
|
||
"EvictionIntervalMs": 5000
|
||
}
|
||
},
|
||
|
||
// ── Serilog ─────────────────────────────────────────────────────────────────────────────
|
||
// Structured log output. Default: Information level, rolling-file under ProgramData.
|
||
// The EventLogBridge writes Error+ events to the Windows Application Event Log
|
||
// automatically when the service runs under the SCM (not under dotnet run).
|
||
"Serilog": {
|
||
"Using": [ "Serilog.Sinks.Console", "Serilog.Sinks.File" ],
|
||
"MinimumLevel": {
|
||
"Default": "Information",
|
||
"Override": {
|
||
"Microsoft": "Warning",
|
||
"System": "Warning"
|
||
}
|
||
},
|
||
"WriteTo": [
|
||
{
|
||
"Name": "Console",
|
||
"Args": {
|
||
"outputTemplate": "[{Timestamp:HH:mm:ss} {Level:u3}] {Message:lj} {Properties:j}{NewLine}{Exception}"
|
||
}
|
||
},
|
||
{
|
||
"Name": "File",
|
||
"Args": {
|
||
// Rolling log: one file per day, kept for 30 days.
|
||
// Survives uninstall — logs are archived to %ProgramData%\mbproxy.archived-<ts>\.
|
||
"path": "C:\\ProgramData\\mbproxy\\logs\\mbproxy-.log",
|
||
"rollingInterval": "Day",
|
||
"retainedFileCountLimit": 30,
|
||
"outputTemplate": "[{Timestamp:yyyy-MM-dd HH:mm:ss.fff zzz} {Level:u3}] {Message:lj} {Properties:j}{NewLine}{Exception}"
|
||
}
|
||
}
|
||
]
|
||
}
|
||
}
|