Rewrites DiagCommand to match the structure of read/write/subscribe:
- Output goes through CliFx's IConsole instead of System.Console
(kills the 6 CliFx_SystemConsoleShouldBeAvoided build warnings).
- Single concise summary line at the top: `diag <tag> (<sec>s, <status>)`.
- Status now correctly distinguishes ok / error / no-events. A bogus
reference produces a DataChange event with MxCategoryConfigurationError;
that reports as "error", not the previous (incorrect) "ok".
- Adds --llm-json mode mirroring read/write: { query, ok, results: [...] }
with register/add_item/events/totals fields.
- Captures both DataChange and OperationComplete events with status
detail rendered consistently.
- Drops the duplicate "Done. Total events: N" / "diag result: events=N"
trailing lines.
Also fixes exit-code propagation from soft-failure commands. Environment
.ExitCode set inside ExecuteAsync was being overwritten by CliFx's own
return from RunAsync. Program.Main now folds the two:
return cliFxExit != 0 ? cliFxExit : Environment.ExitCode
This restores correct exit-on-failure behavior for both `diag` (error
status) and `write` (timeout / non-Ok ack) without resorting to
CommandException, which would print "ERROR\n<stack trace>" even for an
empty message.
Verified:
diag TestChildObject.TestInt -> EXIT 0, "ok"
diag NoSuchObject.NoSuchAttr -> EXIT 1, "error"
diag --llm-json -> structured envelope, ok flag honors statuses
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
New tool wrapping ArchestrA.MxAccess.LMXProxyServerClass (the same COM
proxy aaObjectViewer / WindowViewer use) as a CliFx CLI for LLM-driven
debugging.
Commands:
- mxa info — loaded MxAccess assembly identity, supported value
types, MxStatusCategory enum.
- mxa read — fetch one or more tag values; subscribes briefly,
captures first OnDataChange per tag, tears down.
- mxa write — write a value with optional --type coercion; advises
first to resolve the attribute type, then waits for
OnWriteComplete with a per-call timeout.
- mxa subscribe — stream OnDataChange events for --seconds; JSON Lines
under --llm-json for piped agent consumption.
- mxa diag — minimal smoke test on a private STA thread; bypasses
the CliFx pipeline for diagnosing apartment / pump
issues.
Implementation notes documented in docs/api-notes.md (reverse-engineered
because AVEVA does not publish a single canonical MxAccess reference):
- Net48 / x86 / [STAThread] are non-negotiable. The CLI runs the entire
CliFx pipeline on a dedicated STA thread.
- COM events are dispatched as Win32 messages; AutoResetEvent.WaitOne
alone does not pump them on this configuration. MxSession.WaitForUpdate
loops Application.DoEvents() + drain + Sleep(20ms) instead.
- Write requires the target attribute's type to be resolved first.
WriteCommand advises and waits for the initial OnDataChange before
calling LMXProxyServerClass.Write to avoid ArgumentException
"Value does not fall within the expected range".
- Errors carry the full MXSTATUS_PROXY[] from MxAccess (Success,
Category, DetectedBy, Detail) so an agent can tell exactly which
layer rejected a request.
Verified against the live ZB galaxy with a writeable tag identified
via grdb (TestChildObject.TestInt, mx_attribute_category=10):
read: 99 (q=192, MxCategoryOk)
write 7: round-tripped — read returned 7 — written back to 99
write str: TestChildObject.TestString round-tripped a timestamp
subscribe: captured initial value plus subsequent change from a
separate process
The vendored ArchestrA.MxAccess.dll is gitignored — it is copied from
C:\Program Files (x86)\ArchestrA\Framework\Bin\ on any System Platform
install per the README.