Comments described the *history* of how the code arrived (phase numbers,
wave IDs, review IDs, dated TODOs) instead of what it does today. That
scaffolding rotted as the codebase evolved. Cleaned 60 source files +
.gitignore; behaviour unchanged (387/387 tests still pass).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Closes the Wave 3 (cleanup) tier of codereviews/2026-05-14/RemediationPlan.md.
Tests: 378 pass / 0 fail (baseline 370 + 8 new W3 regression tests).
Code cleanups:
* PlcMultiplexer: removed dead `elapsedMs` calculation (the actual EWMA
conversion uses Stopwatch ticks two lines below).
* UpstreamPipe.FillAsync: dropped the meaningless `firstRead && remaining
== count ? false : false` ternary; both branches were `false`.
* InFlightByKeyMap.TryAttachOrCreate (always returned `true`) renamed to
`AttachOrCreate` and made `void`. Test sites updated to drop the dead
`bool ok = ...; ok.ShouldBeTrue();` assertions.
* BcdCodec.HasBadNibble promoted from private to internal; the duplicate
copy in BcdPduPipeline removed and the call sites updated to
`BcdCodec.HasBadNibble`.
* PlcMultiplexer watchdog comment fixed: said "1-second floor", code uses
100 ms. Now both agree.
* StatusSnapshotBuilder: simplified the unreachable
`RemoteEp?.ToString() ?? RemoteEp?.Address.ToString() ?? "?"` to
`RemoteEp?.ToString() ?? "?"`.
* Mbproxy.csproj: stale "deferred" Polly comment replaced with a real
description of where Polly is used (BackendConnect + ListenerRecovery).
Doc updates:
* README: added a callout about the unconventional 32-bit BCD wire format
("two base-10000 digits in CDAB", not standard binary CDAB Int32) so
integrators using off-the-shelf clients learn about the silent-corruption
hazard before configuring writes.
* docs/design.md: clarified `cacheMissCount` and `coalescedMissCount`
semantics — "miss" means "did not find a fresh entry / did not coalesce",
NOT "produced a backend round-trip". Operators wanting actual backend
traffic should compute `miss − coalescedHit − exception04`.
* docs/Architecture/ResponseCache.md: documented the structural
"skip invalidation while recovering" gating (no backend reader during
recovery → no FC06/FC16 response → no invalidation).
* docs/Operations/Configuration.md: noted that the Event Log sink is the
custom EventLogBridge, not Serilog.Sinks.EventLog (W2.23 cached check).
* docs/plan/README.md: added a Phase 12 row pointing at the remediation
plan and linking out to codereviews/2026-05-14/.
Test additions (W3 high-value gaps):
* BcdPduPipelineTests:
- FC16_WriteStartsOnHighWord_Of32BitPair_PassesThroughRaw_WithPartialWarning
(symmetric inverse of the existing low-side partial-overlap test).
- FC03_Mixed_16Bit_32Bit_AndNonBcd_InOneRead_OnlyConfiguredSlotsRewritten
(mixed-slot routing in a single FC03 read).
- FC16_Response_PassesThroughUnchanged_RegardlessOfTagMap (FC16 response
carries no register data; rewriter must pass through).
* AdminEndpointTests:
- NonGetMethod_AgainstAdminRoutes_Returns405 (Theory: POST/PUT/DELETE/
PATCH against `/` and `/status.json` must return 405; guards against
an accidental MapPost being added later).
* HotReloadE2ETests:
- E2E_TagListReload_OnCacheablePlc_EmitsCacheFlushedEvent (validates the
W2.8 cache.flushed wiring end-to-end via the real FileSystemWatcher
reload path).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Adds the mbproxy service end-to-end. Phases 00-08 implement the
production-ready single-listener / 1:1-backend transparent Modbus TCP
proxy with bidirectional BCD rewriting for the ~54-PLC DL205/DL260
fleet. Phase 9 replaces the connection layer with a single backend
socket per PLC plus MBAP TxId rewriting, lifting the H2-ECOM100's
4-concurrent-client cap as an operational ceiling.
Phase 9 additions of note:
- PlcMultiplexer + UpstreamPipe + TxIdAllocator + CorrelationMap
- InFlightRequest with IReadOnlyList<InterestedParty> (load-bearing
for Phase 10 read coalescing — do not collapse to a single field)
- Per-request watchdog: surfaces Modbus exception 0x0B to upstream
on BackendRequestTimeoutMs, defending against lost responses,
dead-PLC paths, and pymodbus 3.13.0's concurrent-multiplexed-
request bug (its ServerRequestHandler.last_pdu state race)
- Status DTO + HTML gain inFlight / maxInFlight / txIdWraps /
disconnectCascades / queueDepth (Tier 1.6 in docs/kpi.md)
Tests: 263 unit + 38 E2E. Multiplexer correctness under truly
concurrent backend traffic is proved against a stub backend in
PlcMultiplexerTests; MultiplexerE2ETests paces requests so pymodbus
3.13's single-PDU framer stays in known-good mode.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>