mbproxy/docs: retire superseded design/plan docs and dissolve DL260/
The standalone design.md, kpi.md, operations.md, and the docs/plan/ phase tree were point-in-time planning artefacts now superseded by the topic-organized docs/ tree (Architecture/, Features/, Operations/, Reference/, Testing/). The DL260/ folder mixed a device-reference doc, a test fixture, a sample test, and a screenshot; its contents now live in their natural homes (dl205.md + mbtcp_settings.JPG under docs/Reference/, dl205.json next to its launcher in tests/sim/, sample test dropped). All cross-references in the surviving docs, README, CLAUDE.md, the config template, and source comments are repointed to the new locations. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -4,7 +4,7 @@ The proxy holds one persistent backend TCP socket per PLC and multiplexes many u
|
||||
|
||||
## Why One Backend Connection Per PLC
|
||||
|
||||
An earlier design opened a fresh backend socket for each accepted upstream client (1:1 pairs). That model collapsed against the **AutomationDirect H2-ECOM100**, which caps simultaneous TCP clients at **4 per PLC** (see [`../../DL260/dl205.md`](../../DL260/dl205.md) under "Behavioural Oddities"). The fifth upstream client to attach to a busy PLC was refused at connect, with no recourse other than waiting for an existing pair to drop.
|
||||
An earlier design opened a fresh backend socket for each accepted upstream client (1:1 pairs). That model collapsed against the **AutomationDirect H2-ECOM100**, which caps simultaneous TCP clients at **4 per PLC** (see [`../Reference/dl205.md`](../Reference/dl205.md) under "Behavioural Oddities"). The fifth upstream client to attach to a busy PLC was refused at connect, with no recourse other than waiting for an existing pair to drop.
|
||||
|
||||
Multiplexing replaces 1:N upstream-to-backend with N:1 upstream-to-multiplexer-to-backend:
|
||||
|
||||
@@ -244,4 +244,4 @@ The per-request timeout watchdog described above is the production defence again
|
||||
- [`../Operations/StatusPage.md`](../Operations/StatusPage.md) — `inFlight`, `maxInFlight`, `txIdWraps`, `queueDepth`, `disconnectCascades` counters
|
||||
- [`../Reference/LogEvents.md`](../Reference/LogEvents.md) — `mbproxy.multiplex.*` structured log events
|
||||
- [`../Testing/Simulator.md`](../Testing/Simulator.md) — pymodbus 3.13.0 deferred-handler quirk in detail
|
||||
- [`../../DL260/dl205.md`](../../DL260/dl205.md) — DL205/DL260 quirks including the 4-client ECOM cap
|
||||
- [`../Reference/dl205.md`](../Reference/dl205.md) — DL205/DL260 quirks including the 4-client ECOM cap
|
||||
|
||||
@@ -145,6 +145,4 @@ The simulator used by the end-to-end test suite — a `pymodbus`-based stand-in
|
||||
- [`../Operations/Configuration.md`](../Operations/Configuration.md) — `appsettings.json` schema and tag list shape.
|
||||
- [`../Operations/StatusPage.md`](../Operations/StatusPage.md) — the Kestrel admin endpoint and counter catalog.
|
||||
- [`../Reference/LogEvents.md`](../Reference/LogEvents.md) — stable structured log event names.
|
||||
- [`../design.md`](../design.md) — canonical design decisions and rationale.
|
||||
- [`../Testing/Simulator.md`](../Testing/Simulator.md) — `pymodbus` DL205 simulator used by the end-to-end suite.
|
||||
- [`../plan/README.md`](../plan/README.md) — phase plan with per-phase test inventory.
|
||||
|
||||
@@ -405,5 +405,3 @@ configuration described above.
|
||||
`mbproxy.cache.*` event catalogue with event IDs.
|
||||
- [`../Testing/Simulator.md`](../Testing/Simulator.md) — the
|
||||
`pymodbus` DL205 stand-in used by the end-to-end cache tests.
|
||||
- [`../design.md`](../design.md) — canonical design decisions and
|
||||
rationale.
|
||||
|
||||