mbproxy: initial commit through Phase 9 (TxId multiplexing)
Adds the mbproxy service end-to-end. Phases 00-08 implement the production-ready single-listener / 1:1-backend transparent Modbus TCP proxy with bidirectional BCD rewriting for the ~54-PLC DL205/DL260 fleet. Phase 9 replaces the connection layer with a single backend socket per PLC plus MBAP TxId rewriting, lifting the H2-ECOM100's 4-concurrent-client cap as an operational ceiling. Phase 9 additions of note: - PlcMultiplexer + UpstreamPipe + TxIdAllocator + CorrelationMap - InFlightRequest with IReadOnlyList<InterestedParty> (load-bearing for Phase 10 read coalescing — do not collapse to a single field) - Per-request watchdog: surfaces Modbus exception 0x0B to upstream on BackendRequestTimeoutMs, defending against lost responses, dead-PLC paths, and pymodbus 3.13.0's concurrent-multiplexed- request bug (its ServerRequestHandler.last_pdu state race) - Status DTO + HTML gain inFlight / maxInFlight / txIdWraps / disconnectCascades / queueDepth (Tier 1.6 in docs/kpi.md) Tests: 263 unit + 38 E2E. Multiplexer correctness under truly concurrent backend traffic is proved against a stub backend in PlcMultiplexerTests; MultiplexerE2ETests paces requests so pymodbus 3.13's single-PDU framer stays in known-good mode. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -0,0 +1,56 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
|
||||
|
||||
/// <summary>
|
||||
/// Verifies DL205/DL260 binary-coded-decimal register handling against the
|
||||
/// <c>dl205.json</c> pymodbus profile. HR[1072] = 0x1234 on the profile represents
|
||||
/// decimal 1234 (BCD nibbles). Reading it as <see cref="ModbusDataType.Int16"/> would
|
||||
/// return 0x1234 = 4660; the <see cref="ModbusDataType.Bcd16"/> path decodes 1234.
|
||||
/// </summary>
|
||||
[Collection(ModbusSimulatorCollection.Name)]
|
||||
[Trait("Category", "Integration")]
|
||||
[Trait("Device", "DL205")]
|
||||
public sealed class DL205BcdQuirkTests(ModbusSimulatorFixture sim)
|
||||
{
|
||||
[Fact]
|
||||
public async Task DL205_BCD16_decodes_HR1072_as_decimal_1234()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
|
||||
StringComparison.OrdinalIgnoreCase))
|
||||
{
|
||||
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping (standard profile does not seed HR[1072]).");
|
||||
}
|
||||
|
||||
var options = new ModbusDriverOptions
|
||||
{
|
||||
Host = sim.Host,
|
||||
Port = sim.Port,
|
||||
UnitId = 1,
|
||||
Timeout = TimeSpan.FromSeconds(2),
|
||||
Tags =
|
||||
[
|
||||
new ModbusTagDefinition("DL205_Count_Bcd",
|
||||
ModbusRegion.HoldingRegisters, Address: 1072,
|
||||
DataType: ModbusDataType.Bcd16, Writable: false),
|
||||
new ModbusTagDefinition("DL205_Count_Int16",
|
||||
ModbusRegion.HoldingRegisters, Address: 1072,
|
||||
DataType: ModbusDataType.Int16, Writable: false),
|
||||
],
|
||||
Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-bcd");
|
||||
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await driver.ReadAsync(["DL205_Count_Bcd", "DL205_Count_Int16"],
|
||||
TestContext.Current.CancellationToken);
|
||||
|
||||
results[0].StatusCode.ShouldBe(0u);
|
||||
results[0].Value.ShouldBe(1234, "DL205 BCD register 0x1234 represents decimal 1234 per the DirectLOGIC convention");
|
||||
|
||||
results[1].StatusCode.ShouldBe(0u);
|
||||
results[1].Value.ShouldBe((short)0x1234, "same register read as Int16 returns the raw 0x1234 = 4660 value — proves BCD path is distinct");
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user