Joseph Doherty 5f5d684c44 fix(secrets): CLI set/rotate read the value from stdin or a masked prompt (scadaproj#35)
`secret set`/`rotate` took the plaintext as a positional argument (shell
history, process list), and Program handed argv to
Host.CreateApplicationBuilder, whose command-line config provider crashed on
a value like "-p=Hunter2Secret" with the value in the unhandled
FormatException on stderr.

- SetCommandLine: `set|rotate <name> [-|--value-stdin]`; no value reads piped
  stdin or prompts twice (masked) at a TTY; one trailing newline dropped;
  empty refused. The positional <value> still works and warns on stderr.
- host built from HostApplicationBuilderSettings without argv; startup
  failures print `secret: startup failed: <msg>` and exit 1
- unexpected trailing arguments reported by position, not echoed
- tests: SetCommandLineTests incl. two child-process runs of the built CLI;
  the -p=Hunter2Secret probe fails (leaks) on the old Program.cs
- docs: README, clustered-secrets runbook, CHANGELOG
- code-reviews: Secrets-017 Resolved; README regenerated