Joseph Doherty 846b77f5b4 feat(overview): show historian session-pool depths on the HistorianGateway card
Asked whether the gateway's new session row also covered HistorianGateway.
It did not, and could not: HistorianGateway publishes its pool depths on a
different TIER with a different KEY SET.

  mxaccessgw       active tier   total / ready / faulted        one check
  historiangw      READY  tier   warmSessions / pool / …        TWO checks

The session row is located by the total/ready/faulted triple, so it correctly
ignored these rather than half-matching them. This adds a sibling row instead
of unifying the two behind a shared shape, because there is no such shape -
inventing one would mean rendering a contract neither app publishes.

No poller change was needed: the ready tier's body is already retained, so
this is entirely a rendering change.

Labelled "Sessions pooled", deliberately not "connections". warmSessions is
pool DEPTH - warm pre-authenticated sessions held ready - and sessions are
leased on demand, so the event pool legitimately sits at 0 until something
reads events. Calling that a connection count would make a normal idle pool
read as an outage, so 0 is shown plainly and the row goes red only on
consecutiveFactoryFailures, which is an actual fault.

Pools render read-then-event rather than in dictionary order, so the line is
stable across polls and the pool an operator cares about comes first.

188 tests (183 + 5): ordering, that an idle pool is not painted red, that a
failing factory is, a positive control on the omission assertion, and one
pinning that neither app's row can render the other's data.
2026-08-12 05:16:25 -04:00
..