3e5a5fde81
A session that faulted during the handshake cancelled its writer loop immediately, which could kill its OWN Handshake while it still sat in the control lane: the enqueue -> receive -> validate -> fault path has no yields, while the writer's wakeup waits in the thread-pool queue, so with the peer's handshake already buffered the cancel won the race almost every time (39/40 in the new pinning test). Mismatch detection is symmetric — the peer computes its fail-closed verdict FROM our Handshake — so the healthy peer never learned anything: in tests it waited out the full 15 s receive cap (the register-row-41 flake on SyncSessionTests.Handshake_DigestMismatch_FailsClosed), and in production it would misclassify a permanent schema mismatch as a generic disconnect and reconnect-loop at the fast backoff instead of taking the classified FailedPrecondition -> LogError + max-backoff path. RunAsync's fault teardown now completes both lanes so the writer drains what is already enqueued and exits on its own, with a 2 s deferred cancel as the backstop for a wedged transport. Caller-initiated cancellation is unchanged (the linked token is already cancelled, so shutdown is not delayed), and nothing on the wire changes — a 0.3.0 peer simply receives the Handshake it was always owed. New SyncSessionTests.Handshake_FaultTeardown_StillTransmitsTheLocalHandshake pins the race (40 concurrent preloaded-mismatch sessions; 39/40 red pre-fix, green post-fix). BatchBudgetTests hardened separately: the register's other flaky test (Pump_RowLargerThanTheBudget_IsSentAloneRatherThanStallingTheStream) awaits the scripted-peer channel without ever observing the session task, so ANY session fault surfaced as an opaque 15 s timeout. A run-observing NextAsync overload now races the session task at every read site in the class, so the next flake reports the session's real exception instead. (The handshake-race root cause does not structurally apply to this test — no handshake fault occurs there — so its intermittent timeout is attributed to the fault-hiding wait, now removed.) Suite 200/200 green. Closes ScadaBridge deferred-work register row 41 (cross-repo).