Joseph Doherty 91fb2b48dd docs(health): GrpcDependencyHealthCheck has no consumers - keep it, correct SPEC/README (scadaproj#28)
SPEC 2.4 named OtOpcUa and MxGateway as users; neither is (verified against every
app's default branch; MxGateway worker IPC is named pipes, OtOpcUa deliberately
does not gate readiness on gateway channels). Keep the check (removal is a breaking
API change; small, tested building block), mark it as no-current-consumers in SPEC
2.4/6/7, both READMEs, the shared-contract doc and GAPS.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 14:19:09 -05:00
..

Health (readiness / liveness / active-node)

Second normalized component under the operability cluster. Goal: path to shared code — converge the three sister projects onto a common three-tier health endpoint convention and a set of shared probe implementations, proposed as the ZB.MOM.WW.Health library set (3 packages), while each project keeps its own probe registration and orchestrator wiring.

Why health is a strong normalization candidate

Both OtOpcUa and ScadaBridge trace their health-check structure to the same "ScadaLink three-tier pattern" (HealthEndpoints.cs:13 says so explicitly) but have already diverged in probe logic, status semantics, response writer, and endpoint registration style. MxAccessGateway has no shared ancestry here — it has a single hardcoded /health/live endpoint with no real probes at all. The common core (three tiers, database probe, Akka cluster probe, active-node probe) is re-implemented twice and absent once. Shared probe implementations with configurable policies close the gap without forcing identical behavior onto projects with legitimately different cluster semantics.

Status by project

Adopted by all four apps at 0.3.0; probe coverage re-verified 2026-11-09 (scadaproj#11). Every app calls MapZbHealth() (/healthz, /health/ready, /health/active, canonical JSON). The per-endpoint coverage matrix, SPEC deviations and remaining gaps are in GAPS.md; code-verified detail per app (OtOpcUa, MxAccessGateway, ScadaBridge, HistorianGateway) is in current-state/<project>/CURRENT-STATE.md. The "Why" section above and the bullets below describe the original 2026-06 design rationale.

Normalized vs. left per-project

Normalized (the shared target):

  • Three-tier endpoint convention: /health/ready (tag ready), /health/active (tag active), /healthz (bare liveness). Mapped by app.MapZbHealth() from ZB.MOM.WW.Health.
  • Canonical JSON response writer (lifted from HealthChecks.UI.Client style; no per-project writer wiring needed).
  • IActiveNodeGate seam — generalized from ScadaBridge's ActiveNodeGate; wired into MapZbHealth for automatic active-tier response.
  • GrpcDependencyHealthCheck — reachability probe for a downstream gRPC dependency. Shipped but currently has no consumers (neither OtOpcUa nor MxAccessGateway adopted it; scadaproj#28).
  • AkkaClusterHealthCheck (in ZB.MOM.WW.Health.Akka) with a configurable status policy. Default = ScadaBridge's three-way policy; OtOpcUaCompat preset preserves OtOpcUa's two-way self-Up-among-members scan.
  • ActiveNodeHealthCheck (in ZB.MOM.WW.Health.Akka) with an optional role filter. Role-less = ScadaBridge's behavior (Up + cluster leader); role-filtered = OtOpcUa's AdminRoleLeader behavior.
  • DatabaseHealthCheck<TContext> (in ZB.MOM.WW.Health.EntityFrameworkCore) with default CanConnectAsync and an optional ProbeQuery delegate.
  • AllowAnonymous on all three tiers by default (consistent across all three projects today).

Left per-project (not forced together):

  • Which probes each app registers, their names, and which tags they carry.
  • Orchestrator / Traefik wiring (sidecars, route rules, upstreams).
  • ScadaBridge's HealthMonitoring/ distributed aggregation pipeline (SiteHealthCollector, CentralHealthAggregator, HealthReportSender, etc.) — domain-specific, no shared-library equivalent.
  • MxAccessGateway's GatewayHealthReply metadata (DefaultBackend, WorkerProtocolVersion) — keep as a bespoke /info endpoint.
  • The x86 worker process — out of process and out of scope; the gateway-side no probe observes it directly (worker IPC is named pipes, not gRPC).

Package structure

ZB.MOM.WW.Health ships as three dependency-split packages:

Package Contents Consumers
ZB.MOM.WW.Health Core tiers, MapZbHealth, canonical writer, IActiveNodeGate, GrpcDependencyHealthCheck (no consumers) All three
ZB.MOM.WW.Health.Akka AkkaClusterHealthCheck + status presets, ActiveNodeHealthCheck + role filter OtOpcUa, ScadaBridge
ZB.MOM.WW.Health.EntityFrameworkCore DatabaseHealthCheck<TContext> + optional probe delegate OtOpcUa, ScadaBridge

MxAccessGateway consumes the core package only (no Akka, no EF). OtOpcUa and ScadaBridge consume all three.

Component status