Files
scadaproj/ZB.MOM.WW.LocalDb/src/ZB.MOM.WW.LocalDb.Replication/LocalDbMetrics.cs
T

118 lines
5.3 KiB
C#

using System.Diagnostics.Metrics;
namespace ZB.MOM.WW.LocalDb.Replication;
/// <summary>
/// The replication engine's OpenTelemetry instruments, under the single
/// <c>ZB.MOM.WW.LocalDb.Replication</c> meter (family METRIC-CONVENTIONS §1: meters are named
/// after their root namespace). Optional throughout: the sessions and adapters hold a nullable
/// reference and every call is null-guarded, so replication runs identically whether or not this
/// is registered. Instrument names follow the family metric conventions (lower-case,
/// dot-separated, seconds for durations).
/// </summary>
public sealed class LocalDbMetrics : IDisposable
{
/// <summary>The single meter name every replication instrument is published under.</summary>
public const string MeterName = "ZB.MOM.WW.LocalDb.Replication";
private readonly Meter _meter;
private readonly Counter<long> _applied;
private readonly Counter<long> _conflictsDiscarded;
private readonly Counter<long> _deadLettered;
private readonly Counter<long> _reconnects;
private readonly Counter<long> _snapshots;
private readonly Func<DateTimeOffset> _utcNow;
private bool _disposed;
/// <summary>Creates the meter and its instruments. <paramref name="utcNow"/> is a test seam for the lag gauge's clock; null uses <see cref="DateTimeOffset.UtcNow"/>.</summary>
public LocalDbMetrics(Func<DateTimeOffset>? utcNow = null)
{
_utcNow = utcNow ?? (() => DateTimeOffset.UtcNow);
_meter = new Meter(MeterName, typeof(LocalDbMetrics).Assembly.GetName().Version?.ToString(3));
_applied = _meter.CreateCounter<long>("localdb.sync.applied");
_conflictsDiscarded = _meter.CreateCounter<long>("localdb.sync.conflicts_discarded");
_deadLettered = _meter.CreateCounter<long>("localdb.sync.dead_lettered");
_reconnects = _meter.CreateCounter<long>("localdb.sync.reconnects");
_snapshots = _meter.CreateCounter<long>("localdb.sync.snapshots");
_meter.CreateObservableGauge("localdb.oplog.depth", ObserveOplogDepth, "1");
_meter.CreateObservableGauge("localdb.sync.lag.seconds", ObserveSyncLag, "s");
}
/// <summary>
/// Supplies the current unacked oplog backlog for the <c>localdb.oplog.depth</c> gauge. Invoked
/// only at collection time; a cheap synchronous SELECT is acceptable at that frequency.
/// </summary>
public Func<long>? OplogDepthProvider { get; internal set; }
/// <summary>Supplies the last successful sync time for the <c>localdb.sync.lag.seconds</c> gauge; null means no sync yet, and the gauge then reports no measurement.</summary>
public Func<DateTimeOffset?>? LastSyncUtcProvider { get; internal set; }
/// <summary>The backing meter — exposed so a test <see cref="MeterListener"/> can filter by instance reference rather than the process-shared meter name.</summary>
internal Meter Meter => _meter;
/// <summary>Adds <paramref name="count"/> rows applied from inbound delta batches to <c>localdb.sync.applied</c> (no-op when not positive).</summary>
public void RecordApplied(long count)
{
if (count > 0) _applied.Add(count);
}
/// <summary>Adds <paramref name="count"/> inbound rows that lost LWW to <c>localdb.sync.conflicts_discarded</c> (no-op when not positive).</summary>
public void RecordConflictsDiscarded(long count)
{
if (count > 0) _conflictsDiscarded.Add(count);
}
/// <summary>Adds <paramref name="count"/> poison / over-drift rows routed to the dead-letter table to <c>localdb.sync.dead_lettered</c> (no-op when not positive).</summary>
public void RecordDeadLettered(long count)
{
if (count > 0) _deadLettered.Add(count);
}
/// <summary>Increments <c>localdb.sync.reconnects</c> for one initiator reconnect attempt.</summary>
public void RecordReconnect() => _reconnects.Add(1);
/// <summary>Increments <c>localdb.sync.snapshots</c> with <c>direction=sent</c> for one completed outbound snapshot.</summary>
public void RecordSnapshotSent() =>
_snapshots.Add(1, new KeyValuePair<string, object?>("direction", "sent"));
/// <summary>Increments <c>localdb.sync.snapshots</c> with <c>direction=received</c> for one completed inbound snapshot.</summary>
public void RecordSnapshotReceived() =>
_snapshots.Add(1, new KeyValuePair<string, object?>("direction", "received"));
private IEnumerable<Measurement<long>> ObserveOplogDepth()
{
var provider = OplogDepthProvider;
if (provider is null)
return [];
try
{
return [new Measurement<long>(provider())];
}
catch
{
// The observation SELECT can race a disposed db / closing connection; a scrape must
// never throw, so drop this sample rather than surface a partial value.
return [];
}
}
private IEnumerable<Measurement<double>> ObserveSyncLag()
{
var last = LastSyncUtcProvider?.Invoke();
if (last is null)
return [];
var lag = (_utcNow() - last.Value).TotalSeconds;
if (lag < 0) lag = 0;
return [new Measurement<double>(lag)];
}
/// <summary>Disposes the backing meter; idempotent.</summary>
public void Dispose()
{
if (_disposed)
return;
_meter.Dispose();
_disposed = true;
}
}