fix(localdb): refuse AUTOINCREMENT keys at RegisterReplicated (LocalDb-005)
Each node assigns its own AUTOINCREMENT keys, so two different rows inserted on the two nodes share a pk_json and LWW silently keeps one on both nodes. RegisterReplicated now refuses such a table (detected from SQLite column metadata, before any trigger is installed). A plain INTEGER PRIMARY KEY is still accepted (application-assigned ids are legitimate); the requirement that replicated keys be unique across both nodes is documented in the RegisterReplicated remarks and README Limitations. No ScadaBridge or OtOpcUa replicated table is AUTOINCREMENT. (scadaproj#46) Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
This commit is contained in:
@@ -174,6 +174,8 @@ builder.Services.AddZbLocalDb(builder.Configuration, db =>
|
||||
"CREATE TABLE IF NOT EXISTS widget (id INTEGER PRIMARY KEY, name TEXT, qty INTEGER)")
|
||||
.GetAwaiter().GetResult();
|
||||
db.RegisterReplicated("widget"); // PK required; installs capture triggers
|
||||
// The application assigns widget ids. A key SQLite assigns per node (AUTOINCREMENT, or a NULL
|
||||
// rowid) collides across a pair: AUTOINCREMENT is refused, prefer TEXT GUIDs. See Limitations.
|
||||
});
|
||||
|
||||
// Consume ILocalDb anywhere:
|
||||
@@ -295,6 +297,14 @@ All options are validated at startup (`ZB.MOM.WW.Configuration` validators).
|
||||
|
||||
- **Exactly two nodes.** No mesh / N-node topologies.
|
||||
- **LWW only.** No per-table pluggable conflict resolvers.
|
||||
- **Replicated primary keys must be unique across both nodes.** LWW keys on the primary key,
|
||||
so two different rows inserted on the two nodes under the same key are read as two versions
|
||||
of one row, and one is lost on **both** nodes with no dead-letter and no metric. A key each
|
||||
node assigns on its own cannot replicate: `RegisterReplicated` **refuses an `AUTOINCREMENT`
|
||||
key** (`0.3.6`), and a plain `INTEGER PRIMARY KEY` is accepted only because the application
|
||||
may assign it from a node-scoped range — left `NULL` on insert it loses rows the same way.
|
||||
Use a TEXT GUID minted by the writer (what ScadaBridge's `site_events` and OtOpcUa's alarm
|
||||
store-and-forward did when they moved onto LocalDb).
|
||||
- **BLOB columns are rejected at registration** (a column declared `BLOB` fails
|
||||
`RegisterReplicated`, because `json_object` cannot capture it). A *typeless* column can
|
||||
still hold a BLOB value at runtime, which then surfaces as a write-time error, not a
|
||||
|
||||