From 9b3e6c7d00c62cb6b5f7074ed368b06a1a7e2377 Mon Sep 17 00:00:00 2001 From: Joseph Doherty Date: Mon, 23 Nov 2026 12:20:37 -0500 Subject: [PATCH] docs(history): OtOpcUa gRPC data connections merged --- .claude/skills/sister-project-history/otopcua.md | 1 + 1 file changed, 1 insertion(+) diff --git a/.claude/skills/sister-project-history/otopcua.md b/.claude/skills/sister-project-history/otopcua.md index 0c8350a..0882115 100644 --- a/.claude/skills/sister-project-history/otopcua.md +++ b/.claude/skills/sister-project-history/otopcua.md @@ -696,3 +696,4 @@ on `MonitoredItemNotification.Message` validated by `(ClientHandle, DataValue)`; - **G5 signed off (2026-11-13).** The owner signed off the production deployment checklist as Fleet Admin. Every #615 gate is complete (G5, G6, G9 pass; G8 waived), and #615 is closed. - **G2 + G7 (2026-11-13).** G2: the full suite passed after one real fix (`f416b883`, a bare role literal from `c569f806`). The other failures are filed (#909 Modbus fixture swamped by load, #910, #911). G7: FOCAS live-CNC smoke on DEV vd03 against the Makino Z-34184 31i-B. Owner-approved config deploy `e9fbe63e` added `Axes/X/AbsolutePosition` (surgical PureAdd, no rebuild, ServiceLevel 250; it also cleared the #903 drift chip); 0 `EW_SOCKET`/`EW_HANDLE`. ScadaBridge impact: none (one new raw node). G1 (stale Phase 6 compliance scripts) awaits the owner's decision. - **G1 retired (2026-11-13, `e299dc09`).** The owner retired the Phase 6 compliance scripts; all 56 of their failures checked deliberately deleted v2 code. The `scripts/compliance/phase-6-*.ps1` scripts were deleted. **The v2 GA readiness doc now reads RELEASE-READY**: every exit criterion is met, waived (G8) or retired (G1). +- **gRPC data connections merged (2026-11-23, `95c5e484`).** New `data_connection.v1.DataConnectionService` (`Commons/Protos/data_connection.proto`): browse, metadata, cached read, write and data-change subscribe between explicitly configured nodes of one cluster or across clusters, on a dedicated TLS listener (`DataConnections` host settings). Remote Raw/UNS branches are mapped into the local Raw/UNS trees via `DataConnection` / `DataExport` / `RemoteNamespaceMapping` (two new ConfigDb migrations, `AddGrpcDataConnections` + `AddDataConnectionScopeState`); everything is disabled by default and write-through is off by default. Independent of the mesh command/telemetry/config/pair-sync planes; Akka clusters stay separate. History, alarms and methods are not in this release. Guide: `docs/DataConnections.md`. **Not deployed** (DEV/QA remain on `cdf433a3`). ScadaBridge impact: none until a mapping is configured; mapped branches then appear as ordinary Raw/UNS nodes.