diff --git a/.claude/skills/sister-project-history/otopcua.md b/.claude/skills/sister-project-history/otopcua.md index 0882115..e55a03f 100644 --- a/.claude/skills/sister-project-history/otopcua.md +++ b/.claude/skills/sister-project-history/otopcua.md @@ -697,3 +697,4 @@ on `MonitoredItemNotification.Message` validated by `(ClientHandle, DataValue)`; - **G2 + G7 (2026-11-13).** G2: the full suite passed after one real fix (`f416b883`, a bare role literal from `c569f806`). The other failures are filed (#909 Modbus fixture swamped by load, #910, #911). G7: FOCAS live-CNC smoke on DEV vd03 against the Makino Z-34184 31i-B. Owner-approved config deploy `e9fbe63e` added `Axes/X/AbsolutePosition` (surgical PureAdd, no rebuild, ServiceLevel 250; it also cleared the #903 drift chip); 0 `EW_SOCKET`/`EW_HANDLE`. ScadaBridge impact: none (one new raw node). G1 (stale Phase 6 compliance scripts) awaits the owner's decision. - **G1 retired (2026-11-13, `e299dc09`).** The owner retired the Phase 6 compliance scripts; all 56 of their failures checked deliberately deleted v2 code. The `scripts/compliance/phase-6-*.ps1` scripts were deleted. **The v2 GA readiness doc now reads RELEASE-READY**: every exit criterion is met, waived (G8) or retired (G1). - **gRPC data connections merged (2026-11-23, `95c5e484`).** New `data_connection.v1.DataConnectionService` (`Commons/Protos/data_connection.proto`): browse, metadata, cached read, write and data-change subscribe between explicitly configured nodes of one cluster or across clusters, on a dedicated TLS listener (`DataConnections` host settings). Remote Raw/UNS branches are mapped into the local Raw/UNS trees via `DataConnection` / `DataExport` / `RemoteNamespaceMapping` (two new ConfigDb migrations, `AddGrpcDataConnections` + `AddDataConnectionScopeState`); everything is disabled by default and write-through is off by default. Independent of the mesh command/telemetry/config/pair-sync planes; Akka clusters stay separate. History, alarms and methods are not in this release. Guide: `docs/DataConnections.md`. **Not deployed** (DEV/QA remain on `cdf433a3`). ScadaBridge impact: none until a mapping is configured; mapped branches then appear as ordinary Raw/UNS nodes. +- **gRPC data X0 merged (2026-11-23, `a1591253`).** First phase of the history + alarm forwarding plan (`docs/plans/2026-11-23-grpc-data-connections-history-alarms-plan.md`). Tolerant readers: a `DataOperations` bit a node does not understand is dropped fail-closed (grants nothing) and counted (`otopcua.dataconnection.unknown_operations_dropped`, tag `kind`) at the runtime, the wire decoders, artifact parse and catalog compile, instead of rejecting the whole data-connection snapshot. Bits 32–512 reserved (HistoryRead, AlarmSubscribe/Acknowledge/Confirm/Shelve); authoring still rejects them. Proto fields reserved with descriptor golden tests; new per-RPC header `x-otopcua-data-features` parsed but nothing honoured yet. Recorded-v1-client gate proves v1 wire bytes unchanged. **Rollout rule:** X0 must run on every node of both clusters before any H2/A2 bit is authored. Not deployed. Follow-ups lmxopcua#918/#919. ScadaBridge impact: none.