Joseph Doherty e6341580b3 test(audit): lock null-provider passthrough on CentralAuditWriter
Two follow-ups flagged by code review on Tasks 11/12:

- Lock the back-compat contract for CentralAuditWriter's optional
  `nodeIdentity = null` ctor parameter with two explicit tests
  (`WriteAsync_PassesThroughCallerSourceNode_WhenNoProviderInjected` and
  `WriteAsync_LeavesSourceNodeNull_WhenNoProviderInjected`). The previous
  null-provider path was only exercised incidentally via legacy
  CentralAuditWriterTests setups; the new tests make the contract explicit
  and distinct from the "provider supplied, returns null" path.

- Document why the catch-block log references `evt` rather than the
  post-stamp record: the three logged fields (EventId, Kind, Status) are
  immutable across the filter+stamp chain, so referencing either name is
  equivalent — but the comment warns future maintainers to switch names if
  they ever add a field the chain mutates (e.g. SourceNode).