The Communication module is generally well-structured and matches the design doc's two-transport model (ClusterClient for command/control, gRPC server-streaming for real-time data). The actors keep mutable state on the actor thread, use PipeTo for async work, and the gRPC server/client lifecycle is mostly disciplined. However the review found several High and Medium issues clustered around two themes: (a) gRPC subscription bookkeeping racesSiteStreamGrpcClient overwrites and removes subscription entries by correlation ID without disposal or ownership checks, so reconnect cycles leak CancellationTokenSourcees and can cancel the wrong stream; and (b) missing supervision strategy on the coordinator actors, contrary to the CLAUDE.md "Resume for coordinator actors" decision. Design-doc adherence is otherwise good. Test coverage is broad for happy paths but has gaps around failover, cache mutation races, and the snapshot-timeout cleanup path.

Checklist coverage

# Category Examined Notes
1 Correctness & logic bugs Snapshot-timeout orphan, reconnect not calling CleanupGrpc, subscription-map races.
2 Akka.NET conventions No supervision strategy on coordinators; Sender captured in async-launched closure path.
3 Concurrency & thread safety SiteStreamGrpcClient._subscriptions overwrite/remove race; _siteClients field reassignment unused but non-readonly.
4 Error handling & resilience gRPC reconnect leaks server-side relay; LoadSiteAddressesFromDb swallows DB failures silently.
5 Security No findings in module code. DebugStreamHub auth lives outside this module (Central UI).
6 Performance & resource management Orphaned subscriptions/CTS leaks; SiteStreamGrpcClientFactory.Dispose blocks on async.
7 Design-document adherence GrpcMaxStreamLifetime / keepalive options defined but never applied; hard-coded values used instead.
8 Code organization & conventions Options pattern correct; minor: public records declared in actor files. No structural issues.
9 Testing coverage No tests for snapshot-timeout cleanup, address-cache refresh races, or gRPC server reconnect-leak.
10 Documentation & comments XML comment on DebugStreamBridgeActor says "Persistent actor" — it is not an Akka.Persistence actor.

Findings

Communication-001 — Early stream termination escapes StartStreamAsync's narrow exception handling

Severity Medium
Category Error handling & resilience
Status Resolved
Location src/ScadaLink.Communication/DebugStreamService.cs:130-143

Re-triaged 2026-05-16: originally filed Critical, claiming an orphaned bridge actor and a multi-minute site-side resource leak on every snapshot timeout. On verification that impact does not occur: DebugStreamBridgeActor calls CleanupGrpc() and Context.Stop(Self) on every path that invokes onTerminated (site disconnect, gRPC max-retries, ReceiveTimeout), so it always self-terminates and releases its gRPC subscription; and the pure-timeout path does reach StopStream, which also stops it. The genuine defect described below is an error-handling gap, not a leak — severity corrected to Medium.

Description

StartStreamAsync awaits the initial snapshot inside a try whose only handler is catch (OperationCanceledException). When the stream terminates before the snapshot arrives, onTerminatedWrapper completes the await via snapshotTcs.TrySetException(new InvalidOperationException(...)). That InvalidOperationException is not an OperationCanceledException, so it escapes the catch entirely: the caller (Blazor debug view / SignalR hub) receives a raw, untranslated exception, and StartStreamAsync performs no teardown of its own on that path — it relies implicitly on the bridge actor self-terminating. Cleanup from the service side is therefore not deterministic, and the failure surfaced to the caller is not a meaningful, documented result.

Recommendation

In StartStreamAsync, catch any exception from the snapshot await, deterministically tear down the bridge actor (Tell(StopDebugStream) via the local actor reference, since a racing onTerminatedWrapper may already have removed the session entry), and translate the failure into a meaningful exception for the caller.

Resolution

Resolved 2026-05-16. The catch (OperationCanceledException)-only block in StartStreamAsync was replaced with catch (Exception): it removes the session entry, sends StopDebugStream to the bridge actor via the local reference (idempotent — the actor may already be stopping itself), and throws a descriptive exception — TimeoutException for the 30s timeout, otherwise an InvalidOperationException that names the instance/site and wraps the underlying cause. Regression test DebugStreamServiceTests.StartStreamAsync_StreamTerminatesBeforeSnapshot_ThrowsMeaningfulException fails against the pre-fix code and passes after. Fixed by the commit whose message references Communication-001.

Communication-002 — gRPC reconnect does not unsubscribe the previous stream, leaking site-side relay actors

Severity High
Category Error handling & resilience
Status Resolved
Location src/ScadaLink.Communication/Actors/DebugStreamBridgeActor.cs:170, src/ScadaLink.Communication/Actors/DebugStreamBridgeActor.cs:143

Description

On a gRPC stream error, HandleGrpcError increments the retry count, flips _useNodeA, and schedules OpenGrpcStream. OpenGrpcStream cancels and disposes _grpcCts and starts a fresh SubscribeInstance call — but it never calls client.Unsubscribe(_correlationId) on the old node's client, and the site-side SiteStreamGrpcServer keys active streams by correlation_id only. Because the new subscription goes to the other node (_useNodeA flipped), the old node's SiteStreamGrpcServer still has an active stream + StreamRelayActor + SiteStreamManager subscription for that correlation ID. The old node only learns the client is gone via TCP RST or keepalive — exactly the failure mode that triggered the reconnect (network partition / silent node), so detection may take ~25s or never. Each reconnect can therefore leave a zombie relay actor on the failed node. CleanupGrpc (which does call Unsubscribe) is only invoked on terminal paths, not between reconnect attempts.

Recommendation

Before reconnecting in HandleGrpcError / at the top of OpenGrpcStream, call Unsubscribe(_correlationId) on the client for the previous endpoint (the one that just failed) so the local CTS is cancelled and — where the channel is still alive — the gRPC cancellation reaches the site and stops the relay actor.

Resolution

Resolved 2026-05-16 (commit <pending>). Root cause confirmed against source: HandleGrpcError flipped _useNodeA and scheduled OpenGrpcStream without ever unsubscribing the failed stream, leaving the old node's StreamRelayActor zombie until TCP/keepalive timeout. Fix: HandleGrpcError now resolves the client for the previous endpoint (before flipping _useNodeA) and calls Unsubscribe(_correlationId) on it, so the local CTS is cancelled and gRPC cancellation reaches the still-alive site. Regression test DebugStreamBridgeActorTests.On_GrpcError_Unsubscribes_Old_Stream_Before_Reconnect fails against the pre-fix code and passes after.

Communication-003 — SiteStreamGrpcClient subscription map overwritten without disposal; reconnect can cancel the wrong stream

Severity High
Category Concurrency & thread safety
Status Resolved
Location src/ScadaLink.Communication/Grpc/SiteStreamGrpcClient.cs:77, src/ScadaLink.Communication/Grpc/SiteStreamGrpcClient.cs:106

Description

SubscribeAsync does _subscriptions[correlationId] = cts; (line 77), unconditionally overwriting any existing entry for that correlation ID without cancelling or disposing the previous CancellationTokenSource. The finally block then does _subscriptions.TryRemove(correlationId, out _) (line 106) which removes the entry by key only, regardless of which CTS is stored. Because DebugStreamBridgeActor reuses the same _correlationId across reconnect attempts (and SiteStreamGrpcClientFactory returns the same SiteStreamGrpcClient for a site even after a node flip), two SubscribeAsync calls can briefly share a correlation ID. The first call's finally then removes the second call's CTS entry, so a later Unsubscribe(correlationId) finds nothing and the live stream is never cancelled — an orphan. Conversely the overwritten CTS is leaked (never disposed).

Recommendation

When inserting, cancel+dispose any prior CTS for that correlation ID. In the finally, remove only if the stored CTS is the one this call created (use the TryRemove(KeyValuePair) overload, mirroring what SiteStreamGrpcServer already does with StreamEntry). Consider keying subscriptions by a per-call GUID rather than the caller-supplied correlation ID.

Resolution

Resolved 2026-05-16 (commit <pending>). Root cause confirmed against source: the inline _subscriptions[correlationId] = cts overwrote a prior CTS without cancel/dispose (leak), and the finally's TryRemove(correlationId, out _) removed by key only — a racing reconnect's live CTS could be removed by the prior call's finally, orphaning the live stream. Fix: extracted two internal helpers used by SubscribeAsyncRegisterSubscription cancels+disposes any existing CTS for the correlation ID before inserting, and RemoveSubscription uses the ConcurrentDictionary.TryRemove(KeyValuePair) overload so it removes only the CTS that call created (mirroring SiteStreamGrpcServer's StreamEntry pattern). Regression tests SiteStreamGrpcClientTests.RegisterSubscription_ReusedCorrelationId_CancelsAndDisposesPriorCts and SiteStreamGrpcClientTests.RemoveSubscription_OnlyRemovesOwnCts_NotAReplacement fail against the pre-fix logic and pass after.

Communication-004 — Coordinator actors declare no SupervisorStrategy (design requires Resume)

Severity Medium
Category Akka.NET conventions
Status Resolved
Location src/ScadaLink.Communication/Actors/CentralCommunicationActor.cs:42, src/ScadaLink.Communication/Actors/SiteCommunicationActor.cs:22

Description

CLAUDE.md ("Explicit supervision strategies: Resume for coordinator actors, Stop for short-lived execution actors") requires coordinator actors to use an explicit Resume supervision strategy. CentralCommunicationActor and SiteCommunicationActor are long-lived coordinators (they own the per-site ClusterClient map, debug subscriptions, in-progress deployments) but neither overrides SupervisorStrategy. They fall back to the Akka default (OneForOneStrategy with Restart). A child fault — e.g. a ClusterClient child of CentralCommunicationActor created by DefaultSiteClientFactory — would Restart under the default strategy, and any exception in the coordinator itself would restart it, wiping _siteClients, _debugSubscriptions, and _inProgressDeployments silently. The design intent is Resume so transient child faults do not discard coordinator state.

Recommendation

Override SupervisorStrategy on both actors to return an explicit OneForOneStrategy with Directive.Resume (or the project's standard coordinator strategy), matching the documented decision and other coordinator actors.

Resolution

Resolved 2026-05-16 (commit pending). Root cause confirmed: neither CentralCommunicationActor nor SiteCommunicationActor overrode SupervisorStrategy, so child faults fell back to the Akka default (Restart). Note that an actor's own SupervisorStrategy governs its children — a transient child fault would Restart the child and discard its in-memory state, contrary to the CLAUDE.md "Resume for coordinator actors" decision. Fix: both actors now override SupervisorStrategy() to return a OneForOneStrategy with an unbounded Decider resolving to Directive.Resume (mirroring DataConnectionManagerActor). Regression tests CoordinatorSupervisionTests.CentralCommunicationActor_SupervisorStrategy_IsResume and CoordinatorSupervisionTests.SiteCommunicationActor_SupervisorStrategy_IsResume fail against the pre-fix code (decider yields Restart) and pass after.

Communication-005 — gRPC keepalive and max-stream-lifetime options are defined but never applied

Severity Medium
Category Design-document adherence
Status Resolved
Location src/ScadaLink.Communication/Grpc/SiteStreamGrpcClient.cs:25, src/ScadaLink.Communication/CommunicationOptions.cs:36

Description

CommunicationOptions exposes GrpcKeepAlivePingDelay, GrpcKeepAlivePingTimeout, GrpcMaxStreamLifetime, and GrpcMaxConcurrentStreams, and the design doc's "gRPC Connection Keepalive" section explicitly states these are configurable. However SiteStreamGrpcClient's constructor hard-codes KeepAlivePingDelay = TimeSpan.FromSeconds(15) and KeepAlivePingTimeout = TimeSpan.FromSeconds(10) instead of reading the options. GrpcMaxStreamLifetime (the documented "Session timeout — 4 hours" third layer of dead-client detection) is not referenced anywhere — SiteStreamGrpcServer.SubscribeInstance creates a linked CTS from the call cancellation token only, with no CancelAfter. The 4-hour zombie-stream safety net described in the design doc does not exist in code. GrpcMaxConcurrentStreams is also not wired to the server (SiteStreamGrpcServer takes a maxConcurrentStreams constructor parameter defaulting to 100, but nothing binds the option to it).

Recommendation

Flow CommunicationOptions into SiteStreamGrpcClient and SiteStreamGrpcServer (via the factory / DI). Apply GrpcKeepAlivePingDelay / GrpcKeepAlivePingTimeout to the SocketsHttpHandler, bind GrpcMaxConcurrentStreams to the server's limit, and implement the GrpcMaxStreamLifetime session timeout with CancelAfter on the server-side stream CTS — or, if the 4-hour cap is intentionally dropped, remove the option and update the design doc.

Resolution

Resolved 2026-05-16 (commit pending). Root cause confirmed: SiteStreamGrpcClient hard-coded the keepalive values, GrpcMaxStreamLifetime was referenced nowhere, and GrpcMaxConcurrentStreams was never bound to the server. Fix (scoped to src/ScadaLink.Communication): SiteStreamGrpcClient gained a constructor taking CommunicationOptions and now applies GrpcKeepAlivePingDelay/GrpcKeepAlivePingTimeout to its SocketsHttpHandler; SiteStreamGrpcClientFactory gained an IOptions<CommunicationOptions> DI constructor and flows the options into every client it creates; SiteStreamGrpcServer gained an IOptions<CommunicationOptions> DI constructor that binds GrpcMaxConcurrentStreams and implements the documented 4-hour session timeout via CancellationTokenSource.CancelAfter(GrpcMaxStreamLifetime) on the per-stream CTS. The Host's existing AddSingleton<SiteStreamGrpcServer>() registration resolves the new DI constructor via greedy resolution — no Host change required. Regression tests GrpcOptionsWiringTests.SiteStreamGrpcClient_AppliesKeepAliveFromOptions, GrpcOptionsWiringTests.SiteStreamGrpcClientFactory_FlowsOptionsToCreatedClients, and GrpcOptionsWiringTests.SiteStreamGrpcServer_BindsMaxConcurrentStreamsAndLifetimeFromOptions exercise the wiring (they require the new members to even compile).

Communication-006 — Site address load failures are silently swallowed, leaving a stale cache

Severity Medium
Category Error handling & resilience
Status Resolved
Location src/ScadaLink.Communication/Actors/CentralCommunicationActor.cs:204

Description

LoadSiteAddressesFromDb runs the repository query inside Task.Run(...).PipeTo(self). If GetAllSitesAsync throws (database unavailable, transient connection error), the faulted task is piped to Self as a Status.Failure. CentralCommunicationActor has no Receive<Status.Failure> handler, so the failure becomes an unhandled message (logged at debug, not surfaced) and the periodic refresh silently fails. If the first startup load fails the actor runs with an empty _siteClients map — every SiteEnvelope is dropped (line 187) and every Ask times out with no indication of the root cause.

Recommendation

Add a Receive<Status.Failure> handler that logs the load failure at Warning/Error level so operators can distinguish "site has no addresses configured" from "database is down". Optionally surface a health metric for repeated load failures.

Resolution

Resolved 2026-05-16 (commit pending). Root cause confirmed: a faulted LoadSiteAddressesFromDb task is piped to Self as a Status.Failure, but the actor had no handler for it — the failure became an unhandled message (debug-level only) and the periodic refresh failed silently. Fix: added a Receive<Status.Failure> handler that logs the load failure at Warning with the underlying exception as the cause, so operators can distinguish a missing-addresses configuration from a database outage. Regression test CentralCommunicationActorTests.LoadSiteAddressesFailure_IsLoggedNotSilentlySwallowed (repository query throws) asserts the Warning is emitted — it produces no warning against the pre-fix code and passes after.

Communication-007 — SiteStreamGrpcClientFactory.Dispose blocks on async work (sync-over-async)

Severity Medium
Category Performance & resource management
Status Resolved
Location src/ScadaLink.Communication/Grpc/SiteStreamGrpcClientFactory.cs:53

Description

Dispose() calls DisposeAsync().AsTask().GetAwaiter().GetResult(). This is the classic sync-over-async pattern: it blocks the calling thread until all per-site SiteStreamGrpcClient.DisposeAsync calls complete. If Dispose is invoked from a context with a single-threaded synchronization context or from DI container shutdown on a constrained thread pool, this can deadlock or stall host shutdown. The class already implements IAsyncDisposable.

Recommendation

Prefer registering and disposing the factory through IAsyncDisposable only (modern .NET DI honours it for singletons). If a synchronous Dispose must remain, dispose the underlying GrpcChannels directly (synchronous) rather than blocking on the async path, or document why blocking is safe here.

Resolution

Resolved 2026-05-16 (commit pending). Root cause confirmed: Dispose() called DisposeAsync().AsTask().GetAwaiter().GetResult(), the classic sync-over-async pattern. Fix: SiteStreamGrpcClient now also implements IDisposable with a synchronous Dispose() that releases its CancellationTokenSources and underlying GrpcChannel directly (all of that teardown is inherently synchronous); SiteStreamGrpcClientFactory.Dispose() now disposes each cached client via that synchronous path with no blocking on the async path. A CreateClient seam was extracted so the test can substitute a tracking client while still exercising the factory's real caching/disposal machinery. Regression test SiteStreamGrpcClientFactoryDisposeTests.Dispose_DisposesClientsSynchronously_NotViaAsyncPath fails against the pre-fix code (clients disposed via DisposeAsync) and passes after; Dispose_DoesNotDeadlock_UnderSingleThreadedSynchronizationContext guards the stall path.

Communication-008 — Reconnect retry-count reset can mask a flapping stream indefinitely

Severity Medium
Category Correctness & logic bugs
Status Resolved
Location src/ScadaLink.Communication/Actors/DebugStreamBridgeActor.cs:71, src/ScadaLink.Communication/Actors/DebugStreamBridgeActor.cs:174

Description

_retryCount is reset to 0 every time a single AttributeValueChanged or AlarmStateChanged event is received (lines 72, 77). Combined with MaxRetries = 3, a stream that connects, delivers exactly one event, then fails — repeatedly — will reconnect forever. The design doc states "max 3 retries, terminate the session if all retries fail"; the current logic only terminates after 3 consecutive failures with zero intervening events, so a flapping site never trips the limit and the debug session (and its site-side relay) lives on indefinitely. The ReceiveTimeout orphan net is also reset by every received message, so it does not bound this case either.

Recommendation

Either reset _retryCount only after the stream has been stably connected for some minimum duration (e.g. a timer armed on stream open, cancelled on the next error), or keep a separate cumulative reconnect counter / time window that bounds total reconnects regardless of intervening events.

Resolution

Resolved 2026-05-16 (commit pending). Root cause confirmed: _retryCount was reset to 0 on every received AttributeValueChanged/AlarmStateChanged, so a stream that connected, delivered one event, then failed — repeatedly — never tripped MaxRetries. Fix (recommendation option a): the per-event reset was removed; instead OpenGrpcStream arms a single StabilityWindow timer (60s default, internal-settable for tests), and only when it fires (GrpcStreamStable) — i.e. the stream stayed up long enough to be considered recovered — is _retryCount reset. HandleGrpcError cancels that timer, so a stream that fails before the window elapses does not recover its retry budget. A flapping stream therefore terminates after MaxRetries regardless of intervening events. Regression test DebugStreamBridgeActorTests.FlappingStream_DeliveringEventsBetweenFailures_StillTerminatesAfterMaxRetries fails against the pre-fix code (actor never terminates) and passes after; RetryCount_RecoveredOnlyAfterStreamStaysStableForStabilityWindow verifies the budget is recovered after a stable interval. The pre-existing test that codified the buggy per-event reset (Grpc_Error_Resets_RetryCount_On_Successful_Event) was replaced.

Communication-009 — _siteClients field is mutable and reassignable; cache update is not atomic on failure

Severity Low
Category Concurrency & thread safety
Status Resolved
Location src/ScadaLink.Communication/Actors/CentralCommunicationActor.cs:53, src/ScadaLink.Communication/Actors/CentralCommunicationActor.cs:240

Description

_siteClients is a non-readonly Dictionary field. It is only mutated on the actor thread (correct), but the field is needlessly reassignable, and HandleSiteAddressCacheLoaded mutates it in place across several loops. If ActorPath.Parse throws on a malformed address mid-loop (e.g. a site row with a garbage NodeAAddress), the method aborts partway through, having already stopped some ClusterClients and added others — leaving the cache partially updated with no recovery until the next 60s refresh. The other actor mutable collections (_debugSubscriptions, _inProgressDeployments) are correctly readonly.

Recommendation

Mark _siteClients readonly. Validate/parse all addresses up front (or wrap ActorPath.Parse in a try/catch that logs and skips the bad site) so a single malformed site record cannot abort the whole refresh and leave a half-updated cache.

Resolution

Resolved 2026-05-16 (commit pending). Root cause confirmed: _siteClients was a non-readonly field, and HandleSiteAddressCacheLoaded's add/update loop called ActorPath.Parse per site with no guard — a malformed NodeAAddress threw mid-loop and aborted the refresh, leaving the cache half-updated until the next 60s cycle. Fix: _siteClients is now readonly, and the per-site ActorPath.Parse is wrapped in a try/catch that logs the bad address at Warning and continues to the next site, so a single garbage row cannot starve other sites of their ClusterClient. Regression test CentralCommunicationActorTests.MalformedSiteAddress_DoesNotAbortRefresh_OtherSitesStillRegistered (bad site ordered before a good one) fails against the pre-fix code (good site never registered) and passes after.

Communication-010 — DebugStreamBridgeActor XML doc incorrectly describes it as a "Persistent actor"

Severity Low
Category Documentation & comments
Status Resolved
Location src/ScadaLink.Communication/Actors/DebugStreamBridgeActor.cs:10

Description

The class summary opens with "Persistent actor (one per active debug session)...". The actor derives from ReceiveActor, not a persistent actor base class, holds no PersistenceId, and writes no journal/snapshot. "Persistent" is misleading — debug sessions are explicitly "session-based and temporary" per the design doc. A reader could assume state survives restart, which it does not.

Recommendation

Reword the summary to "Long-lived (per active debug session) actor on the central side..." or similar, removing the word "Persistent".

Resolution

Resolved 2026-05-16 (commit pending). Root cause confirmed: the class summary opened with "Persistent actor (one per active debug session)..." but the actor derives from ReceiveActor, holds no PersistenceId, and writes no journal/snapshot. Fix (documentation only — no behaviour change, so no regression test): the summary was reworded to "Long-lived (one per active debug session) actor on the central side. Debug sessions are session-based and temporary — this actor holds no persisted state and does not derive from an Akka.Persistence base class; its state does not survive a restart."

Communication-011 — No test coverage for snapshot-timeout cleanup, address-cache failure, or gRPC reconnect leak

Severity Low
Category Testing coverage
Status Resolved
Location tests/ScadaLink.Communication.Tests/ (module-wide)

Description

The test suite covers happy-path routing, handler-not-registered failures, heartbeat bumping, cache refresh, and gRPC bridge reconnect/retry. However several critical paths identified in this review have no coverage:

  • The DebugStreamService.StartStreamAsync snapshot-timeout path (Communication-001) — no test verifies bridge actor / site subscription teardown on timeout, nor the onTerminated-before-snapshot race that throws a non-OperationCanceledException.
  • CentralCommunicationActor behaviour when LoadSiteAddressesFromDb faults (Communication-006) — RefreshSiteAddresses_UpdatesCache only exercises success.
  • SiteStreamGrpcClient subscription-map overwrite/removal race (Communication-003) and gRPC reconnect not unsubscribing the old node (Communication-002).
  • A malformed NodeAAddress aborting HandleSiteAddressCacheLoaded (Communication-009).

Recommendation

Add tests for: snapshot timeout / pre-snapshot termination cleanup; address-load failure logging and empty-cache behaviour; reusing a correlation ID across SubscribeAsync calls; and a malformed site address during cache refresh.

Resolution

Resolved 2026-05-16 (commit pending). This is a meta-coverage finding; every gap it enumerates is now covered by a regression test (each fails against its pre-fix code and passes after):

  • Snapshot timeout / pre-snapshot termination (Communication-001) — DebugStreamServiceTests.StartStreamAsync_StreamTerminatesBeforeSnapshot_ThrowsMeaningfulException.
  • gRPC reconnect not unsubscribing the old node (Communication-002) — DebugStreamBridgeActorTests.On_GrpcError_Unsubscribes_Old_Stream_Before_Reconnect.
  • SiteStreamGrpcClient subscription-map overwrite/removal race (Communication-003) — SiteStreamGrpcClientTests.RegisterSubscription_ReusedCorrelationId_CancelsAndDisposesPriorCts and RemoveSubscription_OnlyRemovesOwnCts_NotAReplacement.
  • LoadSiteAddressesFromDb fault (Communication-006) — CentralCommunicationActorTests.LoadSiteAddressesFailure_IsLoggedNotSilentlySwallowed.
  • Malformed NodeAAddress aborting HandleSiteAddressCacheLoaded (Communication-009) — CentralCommunicationActorTests.MalformedSiteAddress_DoesNotAbortRefresh_OtherSitesStillRegistered (added with this finding's resolution). The full module suite (dotnet test tests/ScadaLink.Communication.Tests) is green at 111 passing tests.