# Code Review — Communication
| Field | Value |
|-------|-------|
| Module | `src/ScadaLink.Communication` |
| Design doc | `docs/requirements/Component-Communication.md` |
| Status | Reviewed |
| Last reviewed | 2026-05-17 |
| Reviewer | claude-agent |
| Commit reviewed | `39d737e` |
| Open findings | 4 |
## Summary
The Communication module is generally well-structured and matches the design doc's
two-transport model (ClusterClient for command/control, gRPC server-streaming for
real-time data). The actors keep mutable state on the actor thread, use `PipeTo` for
async work, and the gRPC server/client lifecycle is mostly disciplined. However the
review found several High and Medium issues clustered around two themes:
**(a) gRPC subscription bookkeeping races** — `SiteStreamGrpcClient` overwrites and
removes subscription entries by correlation ID without disposal or ownership checks,
so reconnect cycles leak `CancellationTokenSource`es and can cancel the wrong stream;
and **(b) missing supervision strategy** on the coordinator actors, contrary to the
CLAUDE.md "Resume for coordinator actors" decision. Design-doc adherence is otherwise
good. Test coverage is broad for happy paths but has gaps around failover, cache
mutation races, and the snapshot-timeout cleanup path.
#### Re-review 2026-05-17 (commit `39d737e`)
All prior findings (Communication-001..011) are confirmed `Resolved` in this commit
and the fixes hold up against the source. The re-review walked all 10 checklist
categories again and uncovered a previously-missed defect at the centre of the gRPC
node-failover path: **`SiteStreamGrpcClientFactory.GetOrCreate` caches one client per
site identifier and silently ignores the `grpcEndpoint` argument on a cache hit**. The
`DebugStreamBridgeActor` reconnect logic flips `_useNodeA` and passes the *other*
node's endpoint, but the factory hands back the original NodeA-bound client every
time — so the documented "try the other site node endpoint" failover never actually
moves to NodeB (Communication-012). The same caching defect means a site address
change is never picked up because `RemoveSiteAsync` has no production caller
(Communication-013). Two Low findings round out the re-review: an untrusted
gRPC-supplied `correlation_id` flows straight into an Akka actor name
(Communication-014), and the factory's endpoint-reuse defect is masked by the test
mock (Communication-015). Four new findings, all Open: one High, one Medium, two Low.
## Checklist coverage
| # | Category | Examined | Notes |
|---|----------|----------|-------|
| 1 | Correctness & logic bugs | ✓ | Re-review: factory ignores endpoint on cache hit, defeating NodeA→NodeB stream failover (Communication-012). Prior items resolved. |
| 2 | Akka.NET conventions | ✓ | Coordinator `Resume` strategies now present and verified. No new issues. |
| 3 | Concurrency & thread safety | ✓ | Subscription-map register/remove now ownership-checked. `_siteClients` readonly. No new issues. |
| 4 | Error handling & resilience | ✓ | `Status.Failure` handler added; reconnect unsubscribes prior stream. No new issues. |
| 5 | Security | ✓ | Re-review: public gRPC `correlation_id` flows unvalidated into an Akka actor name (Communication-014). |
| 6 | Performance & resource management | ✓ | Synchronous `Dispose` paths fixed; CTS leaks resolved. No new issues. |
| 7 | Design-document adherence | ✓ | Re-review: site gRPC address-change disposal not wired — `RemoveSiteAsync` is dead code (Communication-013). gRPC options now applied. |
| 8 | Code organization & conventions | ✓ | Options pattern correct; public records still declared in actor files (acceptable). No structural issues. |
| 9 | Testing coverage | ✓ | Re-review: prior gaps closed, but the factory mock masks the endpoint-reuse defect — no real node-flip coverage (Communication-015). |
| 10 | Documentation & comments | ✓ | `DebugStreamBridgeActor` summary corrected. No new issues. |
## Findings
### Communication-001 — Early stream termination escapes StartStreamAsync's narrow exception handling
| | |
|--|--|
| Severity | Medium |
| Category | Error handling & resilience |
| Status | Resolved |
| Location | `src/ScadaLink.Communication/DebugStreamService.cs:130-143` |
**Re-triaged 2026-05-16:** originally filed Critical, claiming an orphaned bridge actor
and a multi-minute site-side resource leak on every snapshot timeout. On verification
that impact does **not** occur: `DebugStreamBridgeActor` calls `CleanupGrpc()` and
`Context.Stop(Self)` on every path that invokes `onTerminated` (site disconnect, gRPC
max-retries, `ReceiveTimeout`), so it always self-terminates and releases its gRPC
subscription; and the pure-timeout path does reach `StopStream`, which also stops it.
The genuine defect described below is an error-handling gap, not a leak — severity
corrected to Medium.
**Description**
`StartStreamAsync` awaits the initial snapshot inside a `try` whose only handler is
`catch (OperationCanceledException)`. When the stream terminates before the snapshot
arrives, `onTerminatedWrapper` completes the await via
`snapshotTcs.TrySetException(new InvalidOperationException(...))`. That
`InvalidOperationException` is not an `OperationCanceledException`, so it escapes the
catch entirely: the caller (Blazor debug view / SignalR hub) receives a raw,
untranslated exception, and `StartStreamAsync` performs no teardown of its own on that
path — it relies implicitly on the bridge actor self-terminating. Cleanup from the
service side is therefore not deterministic, and the failure surfaced to the caller is
not a meaningful, documented result.
**Recommendation**
In `StartStreamAsync`, catch any exception from the snapshot await, deterministically
tear down the bridge actor (`Tell(StopDebugStream)` via the local actor reference, since
a racing `onTerminatedWrapper` may already have removed the session entry), and translate
the failure into a meaningful exception for the caller.
**Resolution**
Resolved 2026-05-16. The `catch (OperationCanceledException)`-only block in
`StartStreamAsync` was replaced with `catch (Exception)`: it removes the session entry,
sends `StopDebugStream` to the bridge actor via the local reference (idempotent — the
actor may already be stopping itself), and throws a descriptive exception —
`TimeoutException` for the 30s timeout, otherwise an `InvalidOperationException` that
names the instance/site and wraps the underlying cause. Regression test
`DebugStreamServiceTests.StartStreamAsync_StreamTerminatesBeforeSnapshot_ThrowsMeaningfulException`
fails against the pre-fix code and passes after. Fixed by the commit whose message
references `Communication-001`.
### Communication-002 — gRPC reconnect does not unsubscribe the previous stream, leaking site-side relay actors
| | |
|--|--|
| Severity | High |
| Category | Error handling & resilience |
| Status | Resolved |
| Location | `src/ScadaLink.Communication/Actors/DebugStreamBridgeActor.cs:170`, `src/ScadaLink.Communication/Actors/DebugStreamBridgeActor.cs:143` |
**Description**
On a gRPC stream error, `HandleGrpcError` increments the retry count, flips
`_useNodeA`, and schedules `OpenGrpcStream`. `OpenGrpcStream` cancels and disposes
`_grpcCts` and starts a fresh `SubscribeInstance` call — but it never calls
`client.Unsubscribe(_correlationId)` on the *old* node's client, and the site-side
`SiteStreamGrpcServer` keys active streams by `correlation_id` only. Because the new
subscription goes to the *other* node (`_useNodeA` flipped), the old node's
`SiteStreamGrpcServer` still has an active stream + `StreamRelayActor` +
`SiteStreamManager` subscription for that correlation ID. The old node only learns the
client is gone via TCP RST or keepalive — exactly the failure mode that triggered the
reconnect (network partition / silent node), so detection may take ~25s or never. Each
reconnect can therefore leave a zombie relay actor on the failed node. `CleanupGrpc`
(which *does* call `Unsubscribe`) is only invoked on terminal paths, not between
reconnect attempts.
**Recommendation**
Before reconnecting in `HandleGrpcError` / at the top of `OpenGrpcStream`, call
`Unsubscribe(_correlationId)` on the client for the *previous* endpoint (the one that
just failed) so the local CTS is cancelled and — where the channel is still alive —
the gRPC cancellation reaches the site and stops the relay actor.
**Resolution**
Resolved 2026-05-16 (commit `<pending>`). Root cause confirmed against source:
`HandleGrpcError` flipped `_useNodeA` and scheduled `OpenGrpcStream` without ever
unsubscribing the failed stream, leaving the old node's `StreamRelayActor` zombie until
TCP/keepalive timeout. Fix: `HandleGrpcError` now resolves the client for the
*previous* endpoint (before flipping `_useNodeA`) and calls `Unsubscribe(_correlationId)`
on it, so the local CTS is cancelled and gRPC cancellation reaches the still-alive site.
Regression test `DebugStreamBridgeActorTests.On_GrpcError_Unsubscribes_Old_Stream_Before_Reconnect`
fails against the pre-fix code and passes after.
### Communication-003 — SiteStreamGrpcClient subscription map overwritten without disposal; reconnect can cancel the wrong stream
| | |
|--|--|
| Severity | High |
| Category | Concurrency & thread safety |
| Status | Resolved |
| Location | `src/ScadaLink.Communication/Grpc/SiteStreamGrpcClient.cs:77`, `src/ScadaLink.Communication/Grpc/SiteStreamGrpcClient.cs:106` |
**Description**
`SubscribeAsync` does `_subscriptions[correlationId] = cts;` (line 77),
unconditionally overwriting any existing entry for that correlation ID without
cancelling or disposing the previous `CancellationTokenSource`. The `finally` block
then does `_subscriptions.TryRemove(correlationId, out _)` (line 106) which removes
the entry **by key only, regardless of which CTS is stored**. Because
`DebugStreamBridgeActor` reuses the same `_correlationId` across reconnect attempts
(and `SiteStreamGrpcClientFactory` returns the same `SiteStreamGrpcClient` for a site
even after a node flip), two `SubscribeAsync` calls can briefly share a correlation
ID. The first call's `finally` then removes the *second* call's CTS entry, so a later
`Unsubscribe(correlationId)` finds nothing and the live stream is never cancelled — an
orphan. Conversely the overwritten CTS is leaked (never disposed).
**Recommendation**
When inserting, cancel+dispose any prior CTS for that correlation ID. In the `finally`,
remove only if the stored CTS is the one this call created (use the
`TryRemove(KeyValuePair)` overload, mirroring what `SiteStreamGrpcServer` already does
with `StreamEntry`). Consider keying subscriptions by a per-call GUID rather than the
caller-supplied correlation ID.
**Resolution**
Resolved 2026-05-16 (commit `<pending>`). Root cause confirmed against source: the
inline `_subscriptions[correlationId] = cts` overwrote a prior CTS without
cancel/dispose (leak), and the `finally`'s `TryRemove(correlationId, out _)` removed by
key only — a racing reconnect's live CTS could be removed by the prior call's `finally`,
orphaning the live stream. Fix: extracted two internal helpers used by `SubscribeAsync`
`RegisterSubscription` cancels+disposes any existing CTS for the correlation ID before
inserting, and `RemoveSubscription` uses the `ConcurrentDictionary.TryRemove(KeyValuePair)`
overload so it removes only the CTS that call created (mirroring `SiteStreamGrpcServer`'s
`StreamEntry` pattern). Regression tests
`SiteStreamGrpcClientTests.RegisterSubscription_ReusedCorrelationId_CancelsAndDisposesPriorCts`
and `SiteStreamGrpcClientTests.RemoveSubscription_OnlyRemovesOwnCts_NotAReplacement`
fail against the pre-fix logic and pass after.
### Communication-004 — Coordinator actors declare no SupervisorStrategy (design requires Resume)
| | |
|--|--|
| Severity | Medium |
| Category | Akka.NET conventions |
| Status | Resolved |
| Location | `src/ScadaLink.Communication/Actors/CentralCommunicationActor.cs:42`, `src/ScadaLink.Communication/Actors/SiteCommunicationActor.cs:22` |
**Description**
CLAUDE.md ("Explicit supervision strategies: Resume for coordinator actors, Stop for
short-lived execution actors") requires coordinator actors to use an explicit `Resume`
supervision strategy. `CentralCommunicationActor` and `SiteCommunicationActor` are
long-lived coordinators (they own the per-site ClusterClient map, debug
subscriptions, in-progress deployments) but neither overrides `SupervisorStrategy`.
They fall back to the Akka default (`OneForOneStrategy` with `Restart`). A child fault
— e.g. a `ClusterClient` child of `CentralCommunicationActor` created by
`DefaultSiteClientFactory` — would `Restart` under the default strategy, and any
exception in the coordinator itself would restart it, wiping `_siteClients`,
`_debugSubscriptions`, and `_inProgressDeployments` silently. The design intent is
`Resume` so transient child faults do not discard coordinator state.
**Recommendation**
Override `SupervisorStrategy` on both actors to return an explicit
`OneForOneStrategy` with `Directive.Resume` (or the project's standard coordinator
strategy), matching the documented decision and other coordinator actors.
**Resolution**
Resolved 2026-05-16 (commit pending). Root cause confirmed: neither
`CentralCommunicationActor` nor `SiteCommunicationActor` overrode `SupervisorStrategy`,
so child faults fell back to the Akka default (`Restart`). Note that an actor's own
`SupervisorStrategy` governs its *children* — a transient child fault would `Restart`
the child and discard its in-memory state, contrary to the CLAUDE.md "Resume for
coordinator actors" decision. Fix: both actors now override `SupervisorStrategy()` to
return a `OneForOneStrategy` with an unbounded `Decider` resolving to `Directive.Resume`
(mirroring `DataConnectionManagerActor`). Regression tests
`CoordinatorSupervisionTests.CentralCommunicationActor_SupervisorStrategy_IsResume` and
`CoordinatorSupervisionTests.SiteCommunicationActor_SupervisorStrategy_IsResume` fail
against the pre-fix code (decider yields `Restart`) and pass after.
### Communication-005 — gRPC keepalive and max-stream-lifetime options are defined but never applied
| | |
|--|--|
| Severity | Medium |
| Category | Design-document adherence |
| Status | Resolved |
| Location | `src/ScadaLink.Communication/Grpc/SiteStreamGrpcClient.cs:25`, `src/ScadaLink.Communication/CommunicationOptions.cs:36` |
**Description**
`CommunicationOptions` exposes `GrpcKeepAlivePingDelay`, `GrpcKeepAlivePingTimeout`,
`GrpcMaxStreamLifetime`, and `GrpcMaxConcurrentStreams`, and the design doc's
"gRPC Connection Keepalive" section explicitly states these are configurable. However
`SiteStreamGrpcClient`'s constructor hard-codes `KeepAlivePingDelay =
TimeSpan.FromSeconds(15)` and `KeepAlivePingTimeout = TimeSpan.FromSeconds(10)`
instead of reading the options. `GrpcMaxStreamLifetime` (the documented "Session
timeout — 4 hours" third layer of dead-client detection) is not referenced anywhere
`SiteStreamGrpcServer.SubscribeInstance` creates a linked CTS from the call
cancellation token only, with no `CancelAfter`. The 4-hour zombie-stream safety net
described in the design doc does not exist in code. `GrpcMaxConcurrentStreams` is also
not wired to the server (`SiteStreamGrpcServer` takes a `maxConcurrentStreams`
constructor parameter defaulting to 100, but nothing binds the option to it).
**Recommendation**
Flow `CommunicationOptions` into `SiteStreamGrpcClient` and `SiteStreamGrpcServer`
(via the factory / DI). Apply `GrpcKeepAlivePingDelay` / `GrpcKeepAlivePingTimeout` to
the `SocketsHttpHandler`, bind `GrpcMaxConcurrentStreams` to the server's limit, and
implement the `GrpcMaxStreamLifetime` session timeout with `CancelAfter` on the
server-side stream CTS — or, if the 4-hour cap is intentionally dropped, remove the
option and update the design doc.
**Resolution**
Resolved 2026-05-16 (commit pending). Root cause confirmed: `SiteStreamGrpcClient`
hard-coded the keepalive values, `GrpcMaxStreamLifetime` was referenced nowhere, and
`GrpcMaxConcurrentStreams` was never bound to the server. Fix (scoped to
`src/ScadaLink.Communication`): `SiteStreamGrpcClient` gained a constructor taking
`CommunicationOptions` and now applies `GrpcKeepAlivePingDelay`/`GrpcKeepAlivePingTimeout`
to its `SocketsHttpHandler`; `SiteStreamGrpcClientFactory` gained an
`IOptions<CommunicationOptions>` DI constructor and flows the options into every client
it creates; `SiteStreamGrpcServer` gained an `IOptions<CommunicationOptions>` DI
constructor that binds `GrpcMaxConcurrentStreams` and implements the documented 4-hour
session timeout via `CancellationTokenSource.CancelAfter(GrpcMaxStreamLifetime)` on the
per-stream CTS. The Host's existing `AddSingleton<SiteStreamGrpcServer>()` registration
resolves the new DI constructor via greedy resolution — no Host change required.
Regression tests `GrpcOptionsWiringTests.SiteStreamGrpcClient_AppliesKeepAliveFromOptions`,
`GrpcOptionsWiringTests.SiteStreamGrpcClientFactory_FlowsOptionsToCreatedClients`, and
`GrpcOptionsWiringTests.SiteStreamGrpcServer_BindsMaxConcurrentStreamsAndLifetimeFromOptions`
exercise the wiring (they require the new members to even compile).
### Communication-006 — Site address load failures are silently swallowed, leaving a stale cache
| | |
|--|--|
| Severity | Medium |
| Category | Error handling & resilience |
| Status | Resolved |
| Location | `src/ScadaLink.Communication/Actors/CentralCommunicationActor.cs:204` |
**Description**
`LoadSiteAddressesFromDb` runs the repository query inside `Task.Run(...).PipeTo(self)`.
If `GetAllSitesAsync` throws (database unavailable, transient connection error), the
faulted task is piped to `Self` as a `Status.Failure`. `CentralCommunicationActor` has
no `Receive<Status.Failure>` handler, so the failure becomes an unhandled message
(logged at debug, not surfaced) and the periodic refresh silently fails. If the
*first* startup load fails the actor runs with an empty `_siteClients` map — every
`SiteEnvelope` is dropped (line 187) and every Ask times out with no indication of the
root cause.
**Recommendation**
Add a `Receive<Status.Failure>` handler that logs the load failure at Warning/Error
level so operators can distinguish "site has no addresses configured" from "database
is down". Optionally surface a health metric for repeated load failures.
**Resolution**
Resolved 2026-05-16 (commit pending). Root cause confirmed: a faulted
`LoadSiteAddressesFromDb` task is piped to `Self` as a `Status.Failure`, but the actor
had no handler for it — the failure became an unhandled message (debug-level only) and
the periodic refresh failed silently. Fix: added a `Receive<Status.Failure>` handler
that logs the load failure at `Warning` with the underlying exception as the cause, so
operators can distinguish a missing-addresses configuration from a database outage.
Regression test
`CentralCommunicationActorTests.LoadSiteAddressesFailure_IsLoggedNotSilentlySwallowed`
(repository query throws) asserts the Warning is emitted — it produces no warning
against the pre-fix code and passes after.
### Communication-007 — `SiteStreamGrpcClientFactory.Dispose` blocks on async work (sync-over-async)
| | |
|--|--|
| Severity | Medium |
| Category | Performance & resource management |
| Status | Resolved |
| Location | `src/ScadaLink.Communication/Grpc/SiteStreamGrpcClientFactory.cs:53` |
**Description**
`Dispose()` calls `DisposeAsync().AsTask().GetAwaiter().GetResult()`. This is the
classic sync-over-async pattern: it blocks the calling thread until all per-site
`SiteStreamGrpcClient.DisposeAsync` calls complete. If `Dispose` is invoked from a
context with a single-threaded synchronization context or from DI container shutdown
on a constrained thread pool, this can deadlock or stall host shutdown. The class
already implements `IAsyncDisposable`.
**Recommendation**
Prefer registering and disposing the factory through `IAsyncDisposable` only (modern
.NET DI honours it for singletons). If a synchronous `Dispose` must remain, dispose
the underlying `GrpcChannel`s directly (synchronous) rather than blocking on the async
path, or document why blocking is safe here.
**Resolution**
Resolved 2026-05-16 (commit pending). Root cause confirmed: `Dispose()` called
`DisposeAsync().AsTask().GetAwaiter().GetResult()`, the classic sync-over-async pattern.
Fix: `SiteStreamGrpcClient` now also implements `IDisposable` with a synchronous
`Dispose()` that releases its CancellationTokenSources and underlying `GrpcChannel`
directly (all of that teardown is inherently synchronous); `SiteStreamGrpcClientFactory.Dispose()`
now disposes each cached client via that synchronous path with no blocking on the async
path. A `CreateClient` seam was extracted so the test can substitute a tracking client
while still exercising the factory's real caching/disposal machinery. Regression test
`SiteStreamGrpcClientFactoryDisposeTests.Dispose_DisposesClientsSynchronously_NotViaAsyncPath`
fails against the pre-fix code (clients disposed via `DisposeAsync`) and passes after;
`Dispose_DoesNotDeadlock_UnderSingleThreadedSynchronizationContext` guards the stall path.
### Communication-008 — Reconnect retry-count reset can mask a flapping stream indefinitely
| | |
|--|--|
| Severity | Medium |
| Category | Correctness & logic bugs |
| Status | Resolved |
| Location | `src/ScadaLink.Communication/Actors/DebugStreamBridgeActor.cs:71`, `src/ScadaLink.Communication/Actors/DebugStreamBridgeActor.cs:174` |
**Description**
`_retryCount` is reset to 0 every time a single `AttributeValueChanged` or
`AlarmStateChanged` event is received (lines 72, 77). Combined with `MaxRetries = 3`,
a stream that connects, delivers exactly one event, then fails — repeatedly — will
reconnect forever. The design doc states "max 3 retries, terminate the session if all
retries fail"; the current logic only terminates after 3 *consecutive* failures with
zero intervening events, so a flapping site never trips the limit and the debug
session (and its site-side relay) lives on indefinitely. The `ReceiveTimeout` orphan
net is also reset by every received message, so it does not bound this case either.
**Recommendation**
Either reset `_retryCount` only after the stream has been stably connected for some
minimum duration (e.g. a timer armed on stream open, cancelled on the next error), or
keep a separate cumulative reconnect counter / time window that bounds total
reconnects regardless of intervening events.
**Resolution**
Resolved 2026-05-16 (commit pending). Root cause confirmed: `_retryCount` was reset to
0 on every received `AttributeValueChanged`/`AlarmStateChanged`, so a stream that
connected, delivered one event, then failed — repeatedly — never tripped `MaxRetries`.
Fix (recommendation option a): the per-event reset was removed; instead `OpenGrpcStream`
arms a single `StabilityWindow` timer (60s default, internal-settable for tests), and
only when it fires (`GrpcStreamStable`) — i.e. the stream stayed up long enough to be
considered recovered — is `_retryCount` reset. `HandleGrpcError` cancels that timer, so
a stream that fails before the window elapses does not recover its retry budget. A
flapping stream therefore terminates after `MaxRetries` regardless of intervening
events. Regression test
`DebugStreamBridgeActorTests.FlappingStream_DeliveringEventsBetweenFailures_StillTerminatesAfterMaxRetries`
fails against the pre-fix code (actor never terminates) and passes after;
`RetryCount_RecoveredOnlyAfterStreamStaysStableForStabilityWindow` verifies the budget
is recovered after a stable interval. The pre-existing test that codified the buggy
per-event reset (`Grpc_Error_Resets_RetryCount_On_Successful_Event`) was replaced.
### Communication-009 — `_siteClients` field is mutable and reassignable; cache update is not atomic on failure
| | |
|--|--|
| Severity | Low |
| Category | Concurrency & thread safety |
| Status | Resolved |
| Location | `src/ScadaLink.Communication/Actors/CentralCommunicationActor.cs:53`, `src/ScadaLink.Communication/Actors/CentralCommunicationActor.cs:240` |
**Description**
`_siteClients` is a non-`readonly` `Dictionary` field. It is only mutated on the actor
thread (correct), but the field is needlessly reassignable, and
`HandleSiteAddressCacheLoaded` mutates it in place across several loops. If
`ActorPath.Parse` throws on a malformed address mid-loop (e.g. a site row with a
garbage `NodeAAddress`), the method aborts partway through, having already stopped
some ClusterClients and added others — leaving the cache partially updated with no
recovery until the next 60s refresh. The other actor mutable collections
(`_debugSubscriptions`, `_inProgressDeployments`) are correctly `readonly`.
**Recommendation**
Mark `_siteClients` `readonly`. Validate/parse all addresses up front (or wrap
`ActorPath.Parse` in a try/catch that logs and skips the bad site) so a single
malformed site record cannot abort the whole refresh and leave a half-updated cache.
**Resolution**
Resolved 2026-05-16 (commit pending). Root cause confirmed: `_siteClients` was a
non-`readonly` field, and `HandleSiteAddressCacheLoaded`'s add/update loop called
`ActorPath.Parse` per site with no guard — a malformed `NodeAAddress` threw mid-loop and
aborted the refresh, leaving the cache half-updated until the next 60s cycle. Fix:
`_siteClients` is now `readonly`, and the per-site `ActorPath.Parse` is wrapped in a
try/catch that logs the bad address at Warning and `continue`s to the next site, so a
single garbage row cannot starve other sites of their ClusterClient. Regression test
`CentralCommunicationActorTests.MalformedSiteAddress_DoesNotAbortRefresh_OtherSitesStillRegistered`
(bad site ordered before a good one) fails against the pre-fix code (good site never
registered) and passes after.
### Communication-010 — `DebugStreamBridgeActor` XML doc incorrectly describes it as a "Persistent actor"
| | |
|--|--|
| Severity | Low |
| Category | Documentation & comments |
| Status | Resolved |
| Location | `src/ScadaLink.Communication/Actors/DebugStreamBridgeActor.cs:10` |
**Description**
The class summary opens with "Persistent actor (one per active debug session)...".
The actor derives from `ReceiveActor`, not a persistent actor base class, holds no
`PersistenceId`, and writes no journal/snapshot. "Persistent" is misleading — debug
sessions are explicitly "session-based and temporary" per the design doc. A reader
could assume state survives restart, which it does not.
**Recommendation**
Reword the summary to "Long-lived (per active debug session) actor on the central
side..." or similar, removing the word "Persistent".
**Resolution**
Resolved 2026-05-16 (commit pending). Root cause confirmed: the class summary opened
with "Persistent actor (one per active debug session)..." but the actor derives from
`ReceiveActor`, holds no `PersistenceId`, and writes no journal/snapshot. Fix
(documentation only — no behaviour change, so no regression test): the summary was
reworded to "Long-lived (one per active debug session) actor on the central side. Debug
sessions are session-based and temporary — this actor holds no persisted state and does
not derive from an Akka.Persistence base class; its state does not survive a restart."
### Communication-011 — No test coverage for snapshot-timeout cleanup, address-cache failure, or gRPC reconnect leak
| | |
|--|--|
| Severity | Low |
| Category | Testing coverage |
| Status | Resolved |
| Location | `tests/ScadaLink.Communication.Tests/` (module-wide) |
**Description**
The test suite covers happy-path routing, handler-not-registered failures, heartbeat
bumping, cache refresh, and gRPC bridge reconnect/retry. However several critical
paths identified in this review have no coverage:
- The `DebugStreamService.StartStreamAsync` snapshot-timeout path (Communication-001)
— no test verifies bridge actor / site subscription teardown on timeout, nor the
`onTerminated`-before-snapshot race that throws a non-`OperationCanceledException`.
- `CentralCommunicationActor` behaviour when `LoadSiteAddressesFromDb` faults
(Communication-006) — `RefreshSiteAddresses_UpdatesCache` only exercises success.
- `SiteStreamGrpcClient` subscription-map overwrite/removal race (Communication-003)
and gRPC reconnect not unsubscribing the old node (Communication-002).
- A malformed `NodeAAddress` aborting `HandleSiteAddressCacheLoaded` (Communication-009).
**Recommendation**
Add tests for: snapshot timeout / pre-snapshot termination cleanup; address-load
failure logging and empty-cache behaviour; reusing a correlation ID across
`SubscribeAsync` calls; and a malformed site address during cache refresh.
**Resolution**
Resolved 2026-05-16 (commit pending). This is a meta-coverage finding; every gap it
enumerates is now covered by a regression test (each fails against its pre-fix code and
passes after):
- Snapshot timeout / pre-snapshot termination (Communication-001) —
`DebugStreamServiceTests.StartStreamAsync_StreamTerminatesBeforeSnapshot_ThrowsMeaningfulException`.
- gRPC reconnect not unsubscribing the old node (Communication-002) —
`DebugStreamBridgeActorTests.On_GrpcError_Unsubscribes_Old_Stream_Before_Reconnect`.
- `SiteStreamGrpcClient` subscription-map overwrite/removal race (Communication-003) —
`SiteStreamGrpcClientTests.RegisterSubscription_ReusedCorrelationId_CancelsAndDisposesPriorCts`
and `RemoveSubscription_OnlyRemovesOwnCts_NotAReplacement`.
- `LoadSiteAddressesFromDb` fault (Communication-006) —
`CentralCommunicationActorTests.LoadSiteAddressesFailure_IsLoggedNotSilentlySwallowed`.
- Malformed `NodeAAddress` aborting `HandleSiteAddressCacheLoaded` (Communication-009) —
`CentralCommunicationActorTests.MalformedSiteAddress_DoesNotAbortRefresh_OtherSitesStillRegistered`
(added with this finding's resolution).
The full module suite (`dotnet test tests/ScadaLink.Communication.Tests`) is green at
111 passing tests.
### Communication-012 — gRPC client factory ignores the endpoint on a cache hit, breaking NodeA→NodeB stream failover
| | |
|--|--|
| Severity | High |
| Category | Correctness & logic bugs |
| Status | Open |
| Location | `src/ScadaLink.Communication/Grpc/SiteStreamGrpcClientFactory.cs:39`, `src/ScadaLink.Communication/Actors/DebugStreamBridgeActor.cs:166` |
**Description**
`SiteStreamGrpcClientFactory.GetOrCreate` is `_clients.GetOrAdd(siteIdentifier, _ =>
CreateClient(grpcEndpoint))` — it keys the cache by **site identifier only** and the
`grpcEndpoint` argument is used *exclusively* for the first-ever creation. Every
subsequent call for that site returns the originally-cached `SiteStreamGrpcClient`,
which is permanently bound to the `GrpcChannel` of whatever endpoint was passed first.
`DebugStreamBridgeActor` relies on the opposite behaviour. On a gRPC stream error,
`HandleGrpcError` flips `_useNodeA` and `OpenGrpcStream` recomputes
`endpoint = _useNodeA ? _grpcNodeAAddress : _grpcNodeBAddress`, then calls
`_grpcFactory.GetOrCreate(_siteIdentifier, endpoint)` expecting a client connected to
the *other* node. Because the factory ignores the new endpoint, the bridge actor
reconnects to the **same failed NodeA endpoint** on every retry. The design doc's
core debug-stream failover behaviour ("tries the other site node endpoint", "NodeB if
NodeA failed, or vice versa") is therefore inoperative — when a site node goes down,
the debug stream cannot move to the surviving node and simply exhausts `MaxRetries`
against the dead endpoint and terminates. The `_useNodeA` flip, the `previousEndpoint`
computation in `HandleGrpcError`, and the `CleanupGrpc` endpoint selection are all
dead logic. (Communication-002's `Unsubscribe`-before-reconnect fix still functions,
but it unsubscribes and re-subscribes on the *same* client/node rather than the
intended other node.)
**Recommendation**
Make the per-site client aware of both endpoints, or key the cache by
`(siteIdentifier, endpoint)`, or have `GetOrCreate` detect an endpoint change and
dispose+recreate the cached client. Given the design intent ("Falls back to NodeB if
NodeA connection fails"), the cleanest fix is to give `SiteStreamGrpcClient` (or a
per-site holder) both NodeA/NodeB addresses and let it switch channels internally,
removing the endpoint argument from `GetOrCreate` entirely. Add a test that drives a
real `SiteStreamGrpcClientFactory` through a node flip and asserts the second client
targets the other endpoint.
**Resolution**
_Unresolved._
### Communication-013 — Site gRPC address changes are never applied; `RemoveSiteAsync` has no production caller
| | |
|--|--|
| Severity | Medium |
| Category | Design-document adherence |
| Status | Open |
| Location | `src/ScadaLink.Communication/Grpc/SiteStreamGrpcClientFactory.cs:58` |
**Description**
The design doc states that `SiteStreamGrpcClientFactory` "Disposes clients on site
removal or address change." `RemoveSiteAsync` implements the disposal mechanism, but
a repo-wide search finds **no production caller** — only tests invoke it. Combined
with the cache-by-site-identifier behaviour (Communication-012), the consequence is
that once a site's `SiteStreamGrpcClient` is created, a later edit to that site's
`GrpcNodeAAddress` / `GrpcNodeBAddress` (via the Central UI or CLI) is never reflected
in the cached client — it keeps using the stale channel for the life of the process.
`CentralCommunicationActor` already refreshes the *Akka* address cache every 60s and
recreates ClusterClients on change, but there is no equivalent invalidation path
wired into the gRPC client factory. A site whose gRPC endpoints are corrected after
an initial misconfiguration will never have working debug streaming until the central
node is restarted.
**Recommendation**
Wire a site-removal / address-change signal into `SiteStreamGrpcClientFactory`
e.g. have `CentralCommunicationActor` (which already detects address changes in
`HandleSiteAddressCacheLoaded`) call `RemoveSiteAsync` for sites whose gRPC addresses
changed or were removed, or fold the gRPC endpoints into the same refresh cycle. If
the on-the-fly address-change requirement is intentionally dropped, remove
`RemoveSiteAsync` and correct the design doc.
**Resolution**
_Unresolved._
### Communication-014 — Untrusted gRPC `correlation_id` flows directly into an Akka actor name
| | |
|--|--|
| Severity | Low |
| Category | Security |
| Status | Open |
| Location | `src/ScadaLink.Communication/Grpc/SiteStreamGrpcServer.cs:124` |
**Description**
`SubscribeInstance` is a public gRPC endpoint hosted on each site node. It creates the
relay actor with `$"stream-relay-{request.CorrelationId}-{actorSeq}"` as the actor
name, where `request.CorrelationId` comes straight off the wire. Akka actor names have
a restricted character set; a `correlation_id` containing `/`, whitespace, or other
disallowed characters makes `ActorSystem.ActorOf` throw `InvalidActorNameException`.
That exception is not caught inside `SubscribeInstance`, so it escapes as an unhandled
RPC fault (and after the `_streamSubscriber.Subscribe` / `_activeStreams` entry has
already been set up for the duration, though the `finally` does not run because the
throw is before the `try`). In practice central always supplies a GUID, so impact is
low, but the server is trusting client-supplied input to be actor-name-safe.
**Recommendation**
Validate `request.CorrelationId` on entry (non-empty, matches an expected GUID/safe
pattern) and reject with `StatusCode.InvalidArgument` otherwise; or derive the actor
name solely from the internal `_actorCounter` and keep the correlation ID only as
actor state / dictionary key.
**Resolution**
_Unresolved._
### Communication-015 — No test exercises the real gRPC client factory across a node flip
| | |
|--|--|
| Severity | Low |
| Category | Testing coverage |
| Status | Open |
| Location | `tests/ScadaLink.Communication.Tests/Grpc/DebugStreamBridgeActorTests.cs:401`, `tests/ScadaLink.Communication.Tests/Grpc/SiteStreamGrpcClientFactoryTests.cs` |
**Description**
`DebugStreamBridgeActorTests` exercises the reconnect/failover paths through
`MockSiteStreamGrpcClientFactory`, which returns one fixed mock client regardless of
the `grpcEndpoint` argument. This is exactly the behaviour the *real*
`SiteStreamGrpcClientFactory` exhibits incorrectly (Communication-012), so the mock
masks the defect: `On_GrpcError_Reconnects_To_Other_Node` passes even though the real
factory never reaches the other node. `SiteStreamGrpcClientFactoryTests` only asserts
`GetOrCreate` returns the same client for the same site — it never checks what happens
when the same site is requested with a *different* endpoint.
**Recommendation**
Add a `SiteStreamGrpcClientFactoryTests` case that calls `GetOrCreate(site, endpointA)`
then `GetOrCreate(site, endpointB)` and asserts the second call targets `endpointB`
(it should fail today and pass after Communication-012 is fixed). Have the bridge-actor
test's mock factory track the endpoint per call so node-flip coverage is meaningful.
**Resolution**
_Unresolved._