Phases 1+2 of the design at
docs/plans/2026-05-12-script-scope-access-design.md.
Adds ergonomic scope-aware accessors to compiled scripts. A script
on a composed TempSensor reads its own attribute via
Attributes["Temperature"]; reaches up to the parent via
Parent.Attributes["SpeedRPM"]; invokes a child script via
Children["TempSensor"].CallScript("Sample"). All resolve to the
existing flat Instance.GetAttribute / SetAttribute / CallScript
delegates by prepending the script's canonical path prefix.
Runtime types (SiteRuntime.Scripts.ScopeAccessors):
AttributeAccessor sync indexer + GetAsync / SetAsync
CompositionAccessor Attributes + CallScript
ChildrenAccessor Children["name"] => CompositionAccessor
ScriptGlobals gains Scope, Attributes, Children, Parent properties.
Sync indexer blocks on the Instance Actor Ask; explicit GetAsync /
SetAsync are also available for callers that want to await.
Plumbing:
- Commons.Types.Scripts.ScriptScope record (SelfPath / ParentPath).
- ResolvedScript.Scope (defaults to ScriptScope.Root for back-compat).
- FlatteningService emits new ScriptScope(prefix, "") for each
composed script so a script defined on TempSensor composed under
a parent gets SelfPath = "TempSensor".
- ScriptActor reads the Scope from its ResolvedScript and forwards
it through ScriptExecutionActor into ScriptGlobals on each call.
RevisionHashService not touched: the per-script canonical name
already encodes the composition path, so any structural change
already flips the hash.
10 new unit tests on the path arithmetic. Site/Template engine
suites stay green (129 + 199).
Editor surface (Phase 3: metadata fetch, Phase 4: completion +
SCADA006 / SCADA007 diagnostics) follows in the next commits.
2.6 KiB