scadalink-design/tests/ScadaLink.DataConnectionLayer.Tests/DataConnectionFactoryTests.cs
Joseph Doherty 9dccf8e72f deprecate(lmxproxy): move all LmxProxy code, tests, and docs to deprecated/
LmxProxy is no longer needed. Moved the entire lmxproxy/ workspace, DCL
adapter files, and related docs to deprecated/. Removed LmxProxy registration
from DataConnectionFactory, project reference from DCL, protocol option from
UI, and cleaned up all requirement docs.
2026-04-08 15:56:23 -04:00

56 lines
1.7 KiB
C#

using Microsoft.Extensions.Logging.Abstractions;
using ScadaLink.DataConnectionLayer.Adapters;
namespace ScadaLink.DataConnectionLayer.Tests;
/// <summary>
/// WP-34: Tests for protocol extensibility via DataConnectionFactory.
/// </summary>
public class DataConnectionFactoryTests
{
[Fact]
public void Create_OpcUa_ReturnsOpcUaAdapter()
{
var factory = new DataConnectionFactory(NullLoggerFactory.Instance);
var connection = factory.Create("OpcUa", new Dictionary<string, string>());
Assert.IsType<OpcUaDataConnection>(connection);
}
[Fact]
public void Create_CaseInsensitive()
{
var factory = new DataConnectionFactory(NullLoggerFactory.Instance);
var connection = factory.Create("opcua", new Dictionary<string, string>());
Assert.IsType<OpcUaDataConnection>(connection);
}
[Fact]
public void Create_UnknownProtocol_Throws()
{
var factory = new DataConnectionFactory(NullLoggerFactory.Instance);
var ex = Assert.Throws<ArgumentException>(() =>
factory.Create("UnknownProtocol", new Dictionary<string, string>()));
Assert.Contains("Unknown protocol type", ex.Message);
Assert.Contains("OpcUa", ex.Message);
}
[Fact]
public void RegisterAdapter_ExtendsFactory()
{
var factory = new DataConnectionFactory(NullLoggerFactory.Instance);
// WP-34: Adding new protocol = register adapter
factory.RegisterAdapter("Custom", _ => new OpcUaDataConnection(
new DefaultOpcUaClientFactory(), NullLogger<OpcUaDataConnection>.Instance));
var connection = factory.Create("Custom", new Dictionary<string, string>());
Assert.NotNull(connection);
}
}