namespace ZB.MOM.WW.LmxProxy.Client.Domain;
/// <summary>
/// OPC-style quality codes for SCADA data values.
/// Based on OPC DA quality encoding as a single byte:
/// bits 76 = major (00=Bad, 01=Uncertain, 11=Good),
/// bits 52 = substatus, bits 10 = limit (00=None, 01=Low, 10=High, 11=Constant).
/// </summary>
public enum Quality : byte
{
/// <summary>Bad non-specific.</summary>
Bad = 0,
/// <summary>Bad configuration error in the server.</summary>
Bad_ConfigError = 4,
/// <summary>Bad input source is not connected.</summary>
Bad_NotConnected = 8,
/// <summary>Bad device failure detected.</summary>
Bad_DeviceFailure = 12,
/// <summary>Bad sensor failure detected.</summary>
Bad_SensorFailure = 16,
/// <summary>Bad last known value (communication lost, value stale).</summary>
Bad_LastKnownValue = 20,
/// <summary>Bad communication failure.</summary>
Bad_CommFailure = 24,
/// <summary>Bad item is out of service.</summary>
Bad_OutOfService = 28,
/// <summary>Uncertain non-specific.</summary>
Uncertain = 64,
/// <summary>Uncertain non-specific, low limited.</summary>
Uncertain_LowLimited = 65,
/// <summary>Uncertain non-specific, high limited.</summary>
Uncertain_HighLimited = 66,
/// <summary>Uncertain non-specific, constant.</summary>
Uncertain_Constant = 67,
/// <summary>Uncertain last usable value.</summary>
Uncertain_LastUsable = 68,
/// <summary>Uncertain last usable value, low limited.</summary>
Uncertain_LastUsable_LL = 69,
/// <summary>Uncertain last usable value, high limited.</summary>
Uncertain_LastUsable_HL = 70,
/// <summary>Uncertain last usable value, constant.</summary>
Uncertain_LastUsable_Cnst = 71,
/// <summary>Uncertain sensor not accurate.</summary>
Uncertain_SensorNotAcc = 80,
/// <summary>Uncertain sensor not accurate, low limited.</summary>
Uncertain_SensorNotAcc_LL = 81,
/// <summary>Uncertain sensor not accurate, high limited.</summary>
Uncertain_SensorNotAcc_HL = 82,
/// <summary>Uncertain sensor not accurate, constant.</summary>
Uncertain_SensorNotAcc_C = 83,
/// <summary>Uncertain engineering units exceeded.</summary>
Uncertain_EuExceeded = 84,
/// <summary>Uncertain engineering units exceeded, low limited.</summary>
Uncertain_EuExceeded_LL = 85,
/// <summary>Uncertain engineering units exceeded, high limited.</summary>
Uncertain_EuExceeded_HL = 86,
/// <summary>Uncertain engineering units exceeded, constant.</summary>
Uncertain_EuExceeded_C = 87,
/// <summary>Uncertain sub-normal operating conditions.</summary>
Uncertain_SubNormal = 88,
/// <summary>Uncertain sub-normal, low limited.</summary>
Uncertain_SubNormal_LL = 89,
/// <summary>Uncertain sub-normal, high limited.</summary>
Uncertain_SubNormal_HL = 90,
/// <summary>Uncertain sub-normal, constant.</summary>
Uncertain_SubNormal_C = 91,
/// <summary>Good non-specific.</summary>
Good = 192,
/// <summary>Good low limited.</summary>
Good_LowLimited = 193,
/// <summary>Good high limited.</summary>
Good_HighLimited = 194,
/// <summary>Good constant.</summary>
Good_Constant = 195,
/// <summary>Good local override active.</summary>
Good_LocalOverride = 216,
/// <summary>Good local override active, low limited.</summary>
Good_LocalOverride_LL = 217,
/// <summary>Good local override active, high limited.</summary>
Good_LocalOverride_HL = 218,
/// <summary>Good local override active, constant.</summary>
Good_LocalOverride_C = 219
}