- Deviation #2: document three STA iterations (failed → Task.Run → StaComThread)
- Deviation #7: mark resolved — OnWriteComplete now works via STA message pump
- Deviation #8: note awaited subscription creation fixes flaky subscribe test
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Gap 1: Active health probing verified — 60s recovery after platform restart.
Gap 2: Address-based subscription cleanup — no stale handles.
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
Tested aaBootstrap kill on windev — three gaps identified:
1. No active health probing (IsConnected stays true on dead connection)
2. Stale SubscriptionManager handles after reconnect cycle
3. AVEVA objects don't auto-start after platform crash (platform behavior)
Co-Authored-By: Claude Opus 4.6 (1M context) <noreply@anthropic.com>
The MxAccess docs explicitly state OnWriteComplete always fires after Write().
The real cause is no Windows message pump in the headless service process to
marshal the COM callback. Fire-and-forget is safe for supervisory writes but
would miss secured/verified write rejections (errors 1012/1013).