Rename the user-facing product name from ScadaLink to ScadaBridge across
the six display strings (browser title, sidebar brand, login + not-authorized
headings, dashboard welcome/subtitle). Namespaces, assemblies, config keys,
and _content/ScadaLink.CentralUI asset routes are unchanged.
Apply the technical-light design system: vendor theme.css + IBM Plex fonts
into the CentralUI RCL, include theme.css globally (after Bootstrap so its
--bs-* token overrides win), and restyle the layout chrome to a light
sidebar — white surface, hairline rules, ink text, accent-blue active item,
the brand accent mark. Page markup stays Bootstrap and inherits the warm
paper background, Plex type, accent, and hairline borders via the tokens.
Tests: build 0 warnings; bUnit 542 passed; Playwright 64 passed.
- Add JoeAppEngine folder to OPC UA nodes.json (BTCS, AlarmCntsBySeverity, Scheduler/ScanTime)
- Fix DataConnectionActor: capture Self in PreStart for use from non-actor threads,
preventing Self.Tell failure in Disconnected event handler
- Implement InstanceActor.HandleConnectionQualityChanged to mark attributes Bad on disconnect
- Fix LmxFakeProxy TagMapper to serialize arrays as JSON instead of "System.Int32[]"
- Allow DataType and DataSourceReference updates in TemplateService.UpdateAttributeAsync
- Update test_infra_opcua.md with JoeAppEngine documentation