New deployment-wide options bound from the "OpcUa" section of appsettings.json:
- ApplicationName (default "ScadaLink-DCL")
- TrustedIssuerStorePath / TrustedPeerStorePath / RejectedCertificateStorePath
Empty paths fall back to Path.GetTempPath()/ScadaLink/pki/* so dev runs work
without explicit config — same defaults the hardcoded values previously used.
Wiring:
- ServiceCollectionExtensions binds OpcUaGlobalOptions to the OpcUa section.
- DataConnectionFactory takes IOptions<OpcUaGlobalOptions> and constructs
RealOpcUaClientFactory with the snapshot.
- RealOpcUaClient(globalOptions) replaces the hardcoded ApplicationName and
the three CertificateTrustList store paths in ApplicationConfiguration.
- Parameterless ctors on factory and client preserved for the existing test
suite (32/32 DCL tests still green).
LmxProxy is no longer needed. Moved the entire lmxproxy/ workspace, DCL
adapter files, and related docs to deprecated/. Removed LmxProxy registration
from DataConnectionFactory, project reference from DCL, protocol option from
UI, and cleaned up all requirement docs.
Switches from v1 string-based proto stubs to the production LmxProxyClient
(v2 native TypedValue protocol) via project reference. Deletes 6k+ lines of
generated proto code. Preserves ILmxProxyClient adapter interface for testability.
Replace stub ILmxProxyClient with production proto-generated gRPC client
(RealLmxProxyClient) that connects to LmxProxy servers with x-api-key
metadata header authentication. Includes pre-generated proto stubs for
ARM64 Docker compatibility, updated adapter with proper quality mapping
(Good/Uncertain/Bad), subscription via server-streaming RPC, and 20 unit
tests covering all operations. Updated Component-DataConnectionLayer.md
to reflect the actual implementation.
- Add connection binding UI to Instances page (per-attribute and bulk assign)
- FlatteningService populates Connections dict from bound data connections
- Real OPC UA client using OPC Foundation SDK for live tag subscriptions
- DataConnectionFactory uses RealOpcUaClientFactory by default
- OpcUaDataConnection supports both "endpoint" and "EndpointUrl" config keys