Adds a new HiLo alarm trigger type with four configurable setpoints
(LoLo / Lo / Hi / HiHi). Each setpoint carries an optional priority,
deadband (for hysteresis), and operator message. The site runtime emits
AlarmStateChanged with an AlarmLevel field so consumers can differentiate
warning vs critical bands.
Plumbing:
- new AlarmLevel enum + AlarmStateChanged.Level/Message init properties
- AlarmTriggerEditor (Blazor) gets a HiLo render with severity tinting
- AlarmTriggerConfigCodec extracted from the editor for testability
- sitestream.proto carries level + message over gRPC
- SemanticValidator enforces numeric attribute, setpoint ordering,
non-negative deadband
- on-trigger scripts get an Alarm global (Name/Level/Priority/Message)
so notification routing can branch by severity
- per-instance InstanceAlarmOverride entity + EF migration + flattening
step + CLI commands; HiLo overrides merge setpoint-by-setpoint, binary
types whole-replace
- DebugView shows a Level badge + per-band message tooltip
- App.razor auto-reloads on permanent Blazor circuit failure
- docker/regen-proto.sh automates the proto regen workflow (the linux/arm64
protoc segfault means generated files are checked in for now)
Replace raw-JSON text inputs with rich UI: script parameter/return types use
a JSON Schema builder (SchemaBuilder + JsonSchemaShapeParser, with a migration
to convert existing definitions); alarm trigger config uses a type-aware
editor with a flattened attribute picker (AlarmTriggerEditor). AlarmActor
gains optional direction (rising/falling/either) on RateOfChange triggers.
Three runtime bugs fixed:
- DataConnectionActor: TagValueReceived/TagResolutionSucceeded/Failed not
handled in any Become state — OPC UA values went to dead letters. Added
initial read after subscribe to seed current values immediately.
- AlarmActor: ParseEvalConfig expected "attributeName"/"matchValue"/"min"/
"max" keys but seed data uses "attribute"/"value"/"high"/"low". Added
support for both conventions and !=prefix for not-equal matching.
- InstanceActor: snapshots reported all alarms (including unevaluated) with
correct priorities and source timestamps instead of current UTC. Removed
bogus Vibration template attribute that shadowed Speed's tag mapping.
Wired ISiteHealthCollector calls for script errors (ScriptExecutionActor),
alarm eval errors (AlarmActor), dead letters (DeadLetterMonitorActor), and
S&F buffer depth placeholder. Added instance count tracking (deployed/
enabled/disabled) to SiteHealthReport via DeploymentManagerActor. Updated
Health Dashboard UI to show instance counts per site. All metrics flow
through the existing health report pipeline via ClusterClient.