Reviewer flag on 1bbfad3: "per Component-AuditLog.md, §6.2" pointed at
alog.md numbering, not at any anchor in Component-AuditLog.md (which uses
prose subsection titles). Switch to the prose anchor (Ingestion Paths →
Telemetry forward) so the link resolves.
Code-review feedback on c334de0:
- Ingestion Paths intro said 'Three write paths' but the section has four
subsections (site hot-path append + 3 central writers). Reword to 'Four
paths feed the central AuditLog -- one site originator and three central
writers'.
- Purpose: 'dashboards plus drilldowns plus filter queries' read awkwardly;
switch to standard comma list.
A composition-derived template now stores its contained name — the
composition slot's InstanceName (e.g. "Pump"), unique only within its
owner — instead of the dotted global path ("Motor Controller.Pump").
The qualified hierarchical name is computed on read.
- TemplateNaming.QualifiedName: walks the OwnerCompositionId chain to
build the dotted path; null-safe, cycle-guarded.
- TemplateConfiguration: the unique index on Template.Name becomes
filtered (WHERE IsDerived = 0) — base templates stay globally unique;
derived templates' uniqueness is the existing (TemplateId,
InstanceName) index on TemplateComposition.
- Migration ContainedDerivedTemplateNames: rewrites derived rows to the
contained name; Down rebuilds the dotted names via a recursive CTE
before restoring the global index.
- TemplateService: composition create/rename store the contained name;
the dotted-name collision pre-checks and cascade-rename are removed
(a slot rename no longer touches nested derived templates).
- TemplateEdit: title shows the contained name; the qualified path is a
breadcrumb subtitle; "composed inside" uses the owner's qualified name.
TDD: 4 TemplateNaming tests + updated composition tests. TemplateEngine
293, ConfigurationDatabase 114, CentralUI 316 green. Migration applied to
the dev cluster and verified in the browser (Motor Controller.Pump now
titled "Pump"; nested Motor Controller.Pump.TempSensor resolves).
Design: docs/plans/2026-05-18-contained-template-names-design.md
Conditional and Expression script triggers gain an optional `mode` field
in their TriggerConfiguration JSON:
- OnTrue (default): unchanged edge/per-change firing. An absent mode field
parses as OnTrue, so every existing trigger config behaves identically.
- WhileTrue: fires on the false->true edge, then re-fires on a periodic
timer while the condition holds; stops on the true->false edge. The
re-fire cadence is the script's MinTimeBetweenRuns; with none configured
the trigger degrades to a single edge fire and logs a warning.
ScriptActor tracks condition truth state and manages a dedicated
"whiletrue-trigger" timer. ScriptTriggerConfigCodec and ScriptTriggerEditor
round-trip the mode and expose an OnTrue/WhileTrue selector for the two
trigger kinds. Design: docs/plans/2026-05-18-whiletrue-trigger-mode-design.md
Tests: 7 ScriptActor runtime tests (edge fire, timer re-fire, stop,
re-arm, no-MinTimeBetweenRuns degrade, OnTrue regressions) + 14 codec /
editor tests. SiteRuntime suite 206 green, CentralUI suite 295 green.