Configure HA Energy dashboard (grid + water); add Aeotec HEM8 manuals

Grid now uses PowerMonitorMain (Aeotec ZWA046) per leg since clamp 1 is
reversed; water uses the Droplet integral sensor with flow rate. Refresh
HA version and entity counts.
This commit is contained in:
dohertj2
2026-10-01 09:20:15 -04:00
parent 1f7b1ac487
commit 1424f9469e
5 changed files with 19 additions and 5 deletions
+18 -4
View File
@@ -26,7 +26,7 @@
## Home Assistant
- **Version**: 2026.2.2
- **Version**: 2026.9.4 (verified 2026-10-01)
- **State**: RUNNING
- **Location**: Syracuse, IN (41.41, -85.72)
- **Time zone**: America/New_York
@@ -34,8 +34,8 @@
### Scale
- **2,411 entities** across 76 service domains
- Top entity types: sensor (746), number (285), switch (277), button (228), binary_sensor (219), select (157), device_tracker (110), light (97)
- **2,613 entities** across 80 service domains (804 unavailable as of 2026-10-01 — 289 are stale `new_*` entities)
- Top entity types: sensor (866), switch (297), number (283), button (251), binary_sensor (232), select (161), device_tracker (133), light (94)
### Key Integrations
@@ -51,9 +51,23 @@
| **Voice / AI** | alexa, google_assistant, anthropic, openai_conversation, wyoming |
| **Other** | hacs, cloud, go2rtc, droplet, isy994 |
### Notable Devices
- **PowerMonitorMain** — Aeotec Home Energy Meter 8 (ZWA046), Z-Wave JS node 42, firmware 1.7.7. Entities `sensor.powermonitormain_*` (consumption/production W, kWh, V, A, PF, kVar per channel). Manuals in [manuals/](manuals/). 2-clamp version; endpoints: EP1/EP2 clamp 1 consumption/production, EP3/EP4 clamp 2, EP5/EP6 sum of clamps, EP7/EP8 net.
### Energy Dashboard
- **Grid** (configured 2026-10-01): two import entries, one per leg of PowerMonitorMain:
- Leg 2: `sensor.powermonitormain_electric_consumption_kwh_3` / power `..._consumption_w_3` (EP3, clamp 2 consumption)
- Leg 1: `sensor.powermonitormain_electric_production_kwh` / power `..._production_w` (EP2, clamp 1 "production") — **clamp 1 is installed reversed**, so leg 1 load reports as production (no solar; it reads all night). EP1 consumption has never registered. If clamp 1 is ever flipped, switch this entry to `sensor.powermonitormain_electric_consumption_kwh` (EP1), or replace both with EP5 (`..._consumption_kwh_5`, sum of clamps).
- Don't use EP7 (net consumption) — with a reversed clamp it subtracts leg 1 instead of adding it.
- Replaced `sensor.total_watts_wh` (old IoTaWatt, no longer reporting). Meter statistics begin 2026-09-30.
- **Water** (configured 2026-10-01): consumption `sensor.water_total_usage` (Riemann integral helper of the flow rate, gal, lifetime total; registry device_class override → `water`), flow rate `sensor.droplet_prefilter_flow_rate` (gal/min, `stat_rate`)
- Droplet (utility room, pre-filter): `sensor.droplet_daily_water_usage` / `sensor.droplet_monthly_water_usage` are utility_meter helpers on `sensor.water_total_usage`. Don't use `sensor.droplet_prefilter_water` — it is a per-interval delta that goes negative, not a total.
### Automations
- 23 automations configured
- 24 automations configured
## Notes