dc9c0c950c
Apply the ZB.MOM.WW. prefix to all gateway-side projects, folders,
.csproj/.sln contents, C# namespaces, using directives, generated proto
C# (csharp_namespace + checked-in generated files), InternalsVisibleTo
attributes, project-name string literals (LoadProject, .sln lookups,
worker exe paths, staticwebassets manifest), and the install/script/doc
references that point at any of the above. Migrate the solution from
.sln to .slnx via `dotnet sln migrate` and delete the old file.
External-runtime identifiers are intentionally NOT prefixed so external
configuration keeps working:
- GatewayMetrics.cs MeterName ("MxGateway.Server")
- DashboardAuthenticationDefaults Scheme/Policy ("MxGateway.Dashboard")
- GatewayRequestLoggingMiddleware logger category ("MxGateway.Request")
- StaRuntime thread name ("MxGateway.Worker.STA")
- appsettings.json root section "MxGateway" + env-var prefix
MxGateway__... and secret-name MxGateway:ApiKeyPepper
- C:\ProgramData\MxGateway\ data dir paths
Also fixes two tests that were not rename-related but became visible
while validating the rename:
- WorkerLiveMxAccessSmokeTests.ShutDownAsync: cancellation that the
gateway service correctly maps to RpcException(Cancelled) per gRPC
convention was being misclassified as a stream fault. Added a sibling
catch on RpcException with StatusCode.Cancelled.
- IntegrationTestEnvironment.ResolveRepositoryRoot: extracted IsRepositoryRoot
and made it accept either a .git marker OR a .sln/.slnx next to src/
so the worker-exe walker works in non-git working copies.
clients/proto/proto-inputs.json's protoRoot updated to point at
src/ZB.MOM.WW.MxGateway.Contracts/Protos.
Verified by `dotnet build` and a full `dotnet test` of the .slnx with
MXGATEWAY_RUN_LIVE_{MXACCESS,LDAP,GALAXY}_TESTS=1:
Tests: 472/472 pass
Worker.Tests: 280/280 pass (4 dev-rig [Fact(Skip=...)] skipped)
IntegrationTests: 18/18 pass
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
40 lines
1.3 KiB
Plaintext
40 lines
1.3 KiB
Plaintext
@if (Faults.Count == 0)
|
|
{
|
|
<div class="empty-state">No faults recorded.</div>
|
|
}
|
|
else
|
|
{
|
|
<div class="table-responsive">
|
|
<table class="table table-sm align-middle dashboard-table">
|
|
<thead>
|
|
<tr>
|
|
<th scope="col">Observed</th>
|
|
<th scope="col">Source</th>
|
|
<th scope="col">Session</th>
|
|
<th scope="col">Worker</th>
|
|
<th scope="col">State</th>
|
|
<th scope="col">Message</th>
|
|
</tr>
|
|
</thead>
|
|
<tbody>
|
|
@foreach (DashboardFaultSummary fault in Faults)
|
|
{
|
|
<tr>
|
|
<td>@DashboardDisplay.DateTime(fault.ObservedAt)</td>
|
|
<td>@fault.Source</td>
|
|
<td><code>@DashboardDisplay.Text(fault.SessionId)</code></td>
|
|
<td>@(fault.WorkerProcessId?.ToString(System.Globalization.CultureInfo.InvariantCulture) ?? "-")</td>
|
|
<td><StatusBadge Text="@fault.State" /></td>
|
|
<td>@fault.Message</td>
|
|
</tr>
|
|
}
|
|
</tbody>
|
|
</table>
|
|
</div>
|
|
}
|
|
|
|
@code {
|
|
[Parameter]
|
|
public IReadOnlyList<DashboardFaultSummary> Faults { get; set; } = [];
|
|
}
|