Live windev finding: after a client sent the ShutdownWorker control command the worker exited 0 and WorkerClient moved to Closed on the shutdown ack, but GatewaySession.State stayed Ready (even with an event stream attached) until its lease expired. IWorkerClient has no state-change callback, so the session observes the worker from its own worker-event pump source: WorkerClient enters Closed/Faulted before completing the event channel, so when the enumeration ends ObserveWorkerTerminalState sees the terminal state and faults a Ready session. Faulted rather than Closed: Closed means the gateway closed it and would linger in the registry; a faulted session stays observable with the reason and the faulted-session sweep reaps it, accounting SessionClosed exactly once. Only a Ready session follows its worker, so a gateway- initiated close is unaffected. FakeWorkerHarness-based tests cover the ShutdownWorker exit and a broken worker pipe.