namespace ZB.MOM.WW.MxGateway.Server.Configuration;
/// <summary>
/// Configuration for the gateway's always-on central alarm monitor
/// (<see cref="Alarms.GatewayAlarmMonitor"/>). When <see cref="Enabled"/>
/// is true the gateway opens one gateway-owned worker session dedicated to
/// alarms, caches the active-alarm set, and fans it out to every client
/// through the <c>StreamAlarms</c> RPC — no client opens its own session
/// to see alarms.
/// </summary>
/// <remarks>
/// Defaults preserve current behaviour (alarm monitoring disabled).
/// Operators opt in by setting <c>MxGateway:Alarms:Enabled = true</c> and
/// supplying a canonical <c>\\&lt;machine&gt;\Galaxy!&lt;area&gt;</c>
/// subscription expression. The literal "Galaxy" provider is correct
/// regardless of the configured Galaxy database name (the wnwrap consumer
/// does not accept the database name as the provider).
/// </remarks>
public sealed class AlarmsOptions
{
/// <summary>Gate the gateway's always-on central alarm monitor. Default false.</summary>
public bool Enabled { get; init; }
/// <summary>
/// AVEVA alarm-subscription expression the monitor subscribes on
/// startup. When empty and <see cref="Enabled"/> is true, the gateway
/// falls back to <c>\\$(MachineName)\Galaxy!$(DefaultArea)</c> if
/// <see cref="DefaultArea"/> is set; otherwise the monitor faults with
/// a configuration diagnostic.
/// </summary>
public string SubscriptionExpression { get; init; } = string.Empty;
/// <summary>
/// Optional area name used to compose a default subscription when
/// <see cref="SubscriptionExpression"/> is empty. Combined with
/// <c>Environment.MachineName</c> as
/// <c>\\&lt;MachineName&gt;\Galaxy!&lt;DefaultArea&gt;</c>.
/// </summary>
public string DefaultArea { get; init; } = string.Empty;
/// <summary>
/// How often the monitor reconciles its in-process alarm cache against
/// the worker's authoritative active-alarm snapshot, catching any
/// transitions the live poll-and-diff feed missed. Default 30 seconds;
/// the monitor floors it at 5 seconds.
/// </summary>
public int ReconcileIntervalSeconds { get; init; } = 30;
/// <summary>
/// Configuration for the alarm-manager ↔ subtag fallback mechanism:
/// operating mode, failure-detection thresholds, discovery, and subtag
/// names. Defaults (Mode = "Auto") preserve behaviour when the section is
/// omitted from configuration.
/// </summary>
public AlarmFallbackOptions Fallback { get; init; } = new();
}